HADEX KT3100 Digital Plug-in Thermostat
Code: TI_08840427Product detailed description
KT3100 Plug-in Thermostat with Timer The simultaneous operation of the timer and thermostat does not work! The device is a combination of a plug-in thermostat and a timer, but the thermostat function is not active when the timer is in use. The timer can be set for cyclic operation, a one-time on or off, or a one-time on or off with a delay. Operation is also possible without using the timer. Technical specifications:
Power supply: 100–250 V AC, 50 Hz Load: 16 A (3680 W) Standby current: 0.01 mA Current when relay is on: 0.02 mA
Thermostat temperature range: -40 °C ~ 120 °C Accuracy: ±1 °C Resolution: 0.1 °C Time resolution: 1 minute Maximum settable time interval: 99 hours 59 minutes
Maximum deviation: 10 minutes / 100 hours Reverse operation option – heating or cooling mode External temperature sensor with a 1.8 m cable Setting modes:
You can cycle through the settings modes by pressing the MODE button 1. Thermostat mode without a schedule:
Use the SET button, followed by the DOWN and UP buttons, to set the temperatures for turning the unit on and off; temperatures below -10 °C and above 100 °C can be set in 1 °C increments 2: F01 Cyclic On/Off Mode:
You can set the times when the thermostat turns on and off. You set time intervals, not actual times. The on and off cycles repeat continuously. 3: F02 Delayed-On Mode:
You can set the power-on delay between 1 min and 99 hr 59 min 4: F03 Delayed Power-Off Mode: You can set the power-off delay between 1 min and 99 hr 59 min
5: F04 One-Time On/Off Mode You can set the times at which the thermostat should turn on and off. After the cycle is complete, the thermostat will return to its original settings. User Manual:
1) Plug the thermostat into an outlet. The thermostat is now in non-scheduled mode, and the display shows the current temperature and the set ON and OFF temperatures (default: ON 20 °C and OFF 25 °C). Press the SET button briefly to enter the ON and OFF temperature adjustment mode. You can change these values using the UP and DOWN buttons. If the ON temperature is lower than the OFF temperature, a sun symbol flashes above the current temperature reading and the thermostat is in heating mode. Otherwise, the thermostat is in cooling mode and a snowflake flashes on the display. Once you have finished making your settings, confirm by briefly pressing the MODE button. Press and hold the SET button (5 seconds) to switch from °C to °F.
2) Press the MODE button briefly to activate the timer with modes F01, F02, F03, and F04 (described above). Use the SET, UP, and DOWN buttons to set the on and off times.
3) Press and hold the MODE button (2 seconds) in the corresponding F01–F04 mode to activate the timer function. The display will then flash “ON” or “OFF,” depending on which time period the thermostat is currently in. A blue LED also indicates that the function is active. 4) The thermostat’s normal operation is not maintained in timer mode.