Electric heating cabel Hornisse 3,6mm (67,8m)
Code: HO CABLE/18-1220Product detailed description
Electric heating cables embedded in screed are a common solution in modern floor heating systems, particularly in residential and commercial buildings. These systems are often used in living rooms, kitchens, bathrooms, and service areas where uniform heat distribution is essential. Installers typically work with screed thicknesses of at least 3.6 mm to ensure proper coverage and insulation of the cable. The system requires careful planning to avoid overlapping or sharp bends, which can affect performance and longevity. The Hornisse 3.6mm cable is designed to be flexible and durable, allowing for straightforward installation in a variety of floor structures.
When integrating this cable into a floor heating system, it is important to consider the thermal properties of the screed and the type of floor finish that will be installed above it. The cable must be laid in a consistent pattern to ensure even heat distribution and to prevent cold spots. The installation process typically involves securing the cable to the screed surface before pouring the final layer. This method ensures the cable remains in place and is protected from mechanical damage. The system is compatible with a range of control units and thermostats, allowing for precise temperature regulation and energy efficiency.
Technical parameters
| Code | HO CABLE/18-1220 |
|---|
Installation and connection
The installation of the Hornisse 3.6mm electric heating cable involves laying the cable directly on a screed surface, ensuring it is evenly spaced and free from sharp bends. The cable should be secured using clips or ties to prevent movement during the screed pouring process. The maximum bend radius is 50 mm, and the cable should not be bent beyond this to avoid damage. The power cable is a two-core cable with an earthing braid and has a length of 2.5 m. It is important to check the continuity and insulation resistance of the cable before and after installation to ensure there are no faults. Common installation mistakes include overlapping cable sections, incorrect spacing, and failure to secure the cable properly, all of which can lead to uneven heating or system failure.
Compatibility and accessories
The Hornisse 3.6mm electric heating cable is compatible with a range of floor heating control units and thermostats. It is recommended to use a thermostat that allows for precise temperature control to ensure energy efficiency and comfort. Additional accessories such as temperature sensors and control modules may be required depending on the system configuration. Related products include other lengths of the same cable model, such as the 15m, 22.2m, 37.8m, 44.4m, 61.1m, 83.3m, and 105.6m variants. These can be used to cover different heating areas within the same building or for multiple rooms.
Technical background for designers
The Hornisse 3.6mm electric heating cable operates on a resistive heating principle, where electrical current passes through a conductive core to generate heat. The core is insulated with fluoropolymer, which provides high thermal resistance and durability. The outer insulation is made of PVC, which offers protection against mechanical damage and moisture. The cable is designed to be embedded in a minimum 3.6 mm screed layer, ensuring that the heat is evenly distributed across the floor surface. The efficiency of the system depends on the thickness of the screed, the type of floor finish, and the ambient conditions. Proper spacing and layout of the cable are critical to achieving uniform heat distribution and avoiding hot or cold spots.
Service and operation
Once installed, the Hornisse 3.6mm electric heating cable requires minimal maintenance. Regular checks should be performed to ensure the system is operating within the specified temperature range and that there are no signs of overheating or insulation damage. The control system should be calibrated periodically to maintain accurate temperature regulation. If the system is not functioning correctly, the first step is to check the electrical connections and the continuity of the cable. In the event of a fault, the cable should be disconnected and inspected for damage. The cable is designed for long-term use and does not require scheduled service intervals unless specified in the manufacturer's documentation.
Frequently asked questions
Can the Hornisse 3.6mm cable be used in a bathroom?
Yes, the cable is suitable for use in bathrooms as long as it is installed in a screed layer and the ambient temperature remains above 5°C. The cable is resistant to moisture and can be used in areas with high humidity.
What is the maximum length of the Hornisse 3.6mm cable that can be installed in one room?
The maximum length depends on the power requirements of the room. The cable is available in various lengths, with the longest being 154.2 m. The power output is 18 W/m, so the total power for a 154.2 m cable would be 2775 W.
Is it possible to cut the Hornisse 3.6mm cable to a custom length?
No, the cable is not designed to be cut or modified. It is manufactured in specific lengths and power ratings to ensure proper performance and safety. Using a custom length could affect the electrical balance and reduce the effectiveness of the system.
Can the Hornisse 3.6mm cable be used with a programmable thermostat?
Yes, the cable is compatible with programmable thermostats that allow for precise temperature control. A programmable thermostat can help optimize energy use and improve comfort by adjusting the heating schedule according to the building's needs.
Additional parameters
| Category: | Electric underfloor heating |
|---|---|
| Type: | heating cable |
Discussion
Be the first who will post an article to this item!