Automatic air vent 1/2" with stop valve, brass, for central heating
Code: ODP.A15MORelated products
Product detailed description
Automatic air vents are essential components in central heating systems, ensuring efficient heat transfer by eliminating trapped air. Installers working on residential and commercial heating systems regularly encounter air accumulation in radiators, manifolds and boiler circuits. This type of air vent is commonly used in one- and two-pipe systems, as well as in underfloor heating circuits, where air tends to accumulate in high points.
Correct air venting is crucial for maintaining system performance and preventing corrosion from oxygen in the water. This model is suitable for both new installations and retrofitting existing systems. It is particularly useful in systems with limited access to high points, where manual air venting is impractical. The inclusion of a stop valve adds convenience for maintenance and replacement without draining the system.
Technical parameters
| Material | brass |
|---|---|
| Function | automatic air venting with check valve |
| Max. operating temperature | 120 °C |
| Max. pressure | 10 bar |
| Connection | 1/2 inch |
| EAN | 5900308730492 |
| Weight | 0.1 kg |
| Code | ODP.A15MO |
The maximum operating temperature of 120 °C and pressure rating of 10 bar define the conditions under which the air vent can be safely used. These parameters are critical for selecting the correct model for the system’s operating conditions. The 1/2 inch connection ensures compatibility with standard pipe sizes in central heating systems. The brass construction provides resistance to corrosion and ensures long-term reliability in wet environments.
Installation and connection
Install the air vent vertically at the highest point of the system or circuit, such as on a riser, manifold or near the boiler. Use a 1/2 inch threaded connection to secure it in place. Ensure the stop valve is fully open during installation to allow air to escape. A common mistake is installing the air vent horizontally, which can prevent proper air release. Check the alignment and ensure the vent is not obstructed by insulation or other components. Tighten the connection securely to prevent leaks, but avoid over-tightening which may damage the threads.
Compatibility and accessories
This air vent is compatible with central heating systems using hot or cold water. It is suitable for integration with radiators, manifolds and boiler circuits. No additional accessories are required for standard installation. Ensure the system is compatible with the 1/2 inch connection and that the operating conditions (temperature and pressure) do not exceed the specified limits. No related products are required for this model.
Technical background for designers
The air vent operates using a float mechanism that responds to the presence of air in the system. When air accumulates, the float drops, opening the vent to release the air. The brass material offers good resistance to corrosion and ensures long-term durability in wet environments. The stop valve at the base of the air vent allows for removal or cleaning without draining the system. The integration of the air vent into the system should be planned during the design phase to ensure it is placed at the correct high point. The operating conditions, such as temperature and pressure, directly affect the service life and efficiency of the air vent. Regular maintenance is not required, but the vent should be inspected for blockages or wear during system checks.
Service and operation
During operation, the air vent requires no active maintenance. However, it should be inspected periodically for signs of blockage or wear. If the vent is not releasing air effectively, it may need to be cleaned. The stop valve allows for removal without draining the system. No specific service intervals are required for this model. If the vent is removed for cleaning, ensure the stop valve is closed to prevent water loss. Reinstall the vent in the same position and orientation to maintain proper function.
Frequently asked questions
Can the air vent be installed on a horizontal pipe?
No, the air vent must be installed vertically to ensure proper air release. Horizontal installation may prevent the float mechanism from functioning correctly.
Is the stop valve sufficient to prevent water loss during removal?
Yes, the stop valve at the base of the air vent closes automatically when the vent is removed, preventing water from escaping the system.
Can this air vent be used in a system with a temperature above 120 °C?
No, the maximum operating temperature is 120 °C. Exceeding this limit may damage the internal components and reduce the service life of the air vent.
Is the air vent suitable for use with glycol-based heating fluids?
According to the manufacturer's technical data sheet, the suitability for glycol-based fluids is not specified. Consult the technical data sheet for confirmation.
Additional parameters
| Category: | Vent valves |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.1 kg |
| EAN: | 5900308730492 |
| Availability: | In stock or at supplier |
Discussion
Be the first who will post an article to this item!
