Wholesale e-shop

Atmos S0021 Boiler Thermostat

Code: S0021
–0 %
98499 1 s0021
–0 % €27,10 / pcs €33,33 incl. VAT Measure price:
In stock (3 pcs)

Detailed information

Product detailed description

The Atmos S0021 boiler thermostat is commonly used in solid fuel heating systems to regulate the operation of the boiler fan. It ensures that the fan runs in response to the temperature of the water exiting the boiler. This device is suitable for installation in residential and commercial buildings where Atmos boilers are used, excluding the DC75SE model. Installers working on boiler control systems will find this thermostat useful for maintaining consistent and efficient operation of the boiler.

Typical applications include solid fuel boilers where fan speed must be adjusted to match heat demand. The thermostat integrates with the boiler’s control panel and works in conjunction with other system components such as sensors and actuators. It is designed for straightforward mounting and wiring, making it suitable for both new installations and replacements in existing systems.

Technical parameters

Temperature range40 – 95 °C
Weight0.115 kg
CodeS0021
BrandAtmos

This thermostat is configured for a temperature range of 40–95°C. The range allows precise control of the boiler fan based on the output water temperature, ensuring optimal combustion efficiency and system performance. The temperature settings are critical for matching the thermostat to the boiler’s operational requirements and for ensuring safe and efficient operation.

Installation and connection

Installation involves securing the thermostat to the boiler control panel and connecting it to the fan circuit. The device typically requires standard electrical connections compatible with the boiler’s control system. Technicians should verify that the wiring corresponds to the boiler’s specifications and that all connections are secure and insulated.

  • Mount the thermostat in the designated position on the control panel.
  • Connect the wiring to the appropriate terminals for the fan control circuit.
  • Ensure the thermostat is correctly aligned and fixed to prevent movement during operation.
  • Test the thermostat after installation by monitoring fan operation in response to changes in water temperature.

Common installation errors include incorrect wiring, which can lead to improper fan control or failure to activate. Always double-check the wiring diagram and confirm compatibility with the boiler model before finalising the installation.

Compatibility and accessories

This thermostat is compatible with most Atmos solid fuel boilers, with the exception of the DC75SE model. It is intended for use in systems where fan speed is regulated by output water temperature. The black wheel used on the boiler panel is not included with the thermostat and must be ordered separately if needed. Installers should ensure that all necessary components are available before beginning the installation.

Technical background for designers

The Atmos S0021 operates using a mechanical or electronic sensing mechanism that responds to changes in the temperature of the water leaving the boiler. As the temperature rises or falls, the thermostat adjusts the fan speed accordingly, helping to maintain stable combustion conditions. The materials used are selected for durability and resistance to thermal cycling, ensuring long-term reliability in boiler environments.

Integration into the boiler system requires proper alignment with the control panel and correct electrical connections. The efficiency of the thermostat is influenced by factors such as the accuracy of the temperature sensor and the responsiveness of the fan control circuit. Regular checks for wear and damage can help maintain optimal performance over time.

Service and operation

Periodic inspection is recommended to ensure the thermostat remains functional and responsive to temperature changes. Technicians should check for signs of wear on the control mechanism and verify that the wiring remains intact and free from corrosion. If the fan fails to respond correctly to temperature variations, the thermostat may require adjustment or replacement.

Key checkpoints during service include:

  • Confirming that the thermostat is securely mounted and aligned.
  • Testing the fan response to known temperature changes.
  • Inspecting the wiring for signs of damage or disconnection.
  • Verifying that the control panel functions correctly with the installed thermostat.

Frequently asked questions

Can the Atmos S0021 be used with any Atmos boiler model?
It is suitable for most Atmos models except the DC75SE. Always confirm compatibility with the specific boiler before installation.

Is the black wheel included in the package?
No, the black wheel for the boiler panel is not included and must be ordered separately if needed.

How does the thermostat affect fan operation?
The thermostat controls the fan based on the temperature of the water leaving the boiler, ensuring the fan runs when necessary to maintain optimal combustion.

Can the temperature range be adjusted?
The thermostat is set for a fixed temperature range of 40–95°C and cannot be modified. This range is designed to suit standard boiler operation.

Additional parameters

Category: Spare parts for the control panel (thermostats, switches)
Warranty: 2 years
Weight: 0.115 kg
Temperature range: 40 – 95 °C

Discussion

Be the first who will post an article to this item!

Do not fill out this field