Adex midi regulation

Code: 125006
€189,40 / pcs €232,96 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

The AVANSA Adex midi regulation is a control solution for wood-fired boiler systems that already include internal time and temperature controls. It is commonly used in residential and commercial heating systems where the boiler and pump are managed separately, and the primary requirement is the control of a mixing valve to regulate heat distribution. This regulator is also suitable for systems with thermal storage tanks and gas boilers where automatic system on/off functionality is not required. It is often installed in systems where the boiler is manually operated or where the control system is designed to manage only the mixing valve for temperature regulation.

The Adex midi is typically used in installations where the boiler is not fully automated and requires manual or semi-automated operation. It is ideal for systems that require temperature control of the return water to prevent overheating or underheating, particularly in systems with thermal storage tanks. The regulator works in conjunction with an external temperature sensor to monitor and adjust the mixing valve accordingly. It is not designed to control the boiler or circulation pump directly, making it a complementary component in a larger control system.

Technical parameters

Weight1 kg
Code125006
BrandAVANSA
The technical parameters for the AVANSA Adex midi are not explicitly provided in the product brief. However, the regulator is designed to operate with an external temperature sensor and is intended for use with systems that have built-in boiler controls. When selecting this regulator, ensure that the system includes a compatible mixing valve and that the control logic aligns with the boiler's internal time and temperature settings. The regulator does not manage the boiler or pump, so these components must be controlled separately.

Installation and connection

Installation of the AVANSA Adex midi involves connecting the regulator to the mixing valve and an external temperature sensor. The regulator must be mounted in a location that allows for easy access and visibility for monitoring. The wiring should be connected according to the manufacturer's instructions, ensuring that the sensor is correctly positioned to monitor the desired temperature point in the system. It is important to verify that the mixing valve is compatible with the regulator and that the system's control logic does not require additional components for boiler or pump control. Common installation errors include incorrect sensor placement, which can lead to inaccurate temperature readings, and failure to isolate the regulator from boiler or pump control functions.

Compatibility and accessories

The AVANSA Adex midi is compatible with wood-fired boilers that have built-in time and temperature controls and require only mixing valve regulation. It is also suitable for systems with thermal storage tanks and gas boilers where automatic system activation is not required. To complete the installation, an external temperature sensor must be ordered separately.

Technical background for designers

The AVANSA Adex midi operates by receiving temperature data from an external sensor and using this information to adjust the position of the mixing valve. This helps maintain a consistent temperature in the system and prevents overheating or underheating. The regulator is constructed using durable materials suitable for use in heating systems. Its design allows for integration into systems where the boiler and pump are controlled separately, making it a flexible solution for various installation scenarios. The efficiency and service life of the regulator depend on the accuracy of the temperature sensor and the proper maintenance of the mixing valve. Regular inspection of the sensor and valve connections is recommended to ensure reliable operation.

Service and operation

Maintenance of the AVANSA Adex midi involves checking the external temperature sensor for accuracy and ensuring that the connections to the mixing valve are secure. The sensor should be inspected periodically to confirm that it is positioned correctly and not obstructed by debris or insulation. The mixing valve should also be checked for proper operation and cleaned if necessary. No specific service intervals are provided in the product brief, but it is recommended to perform routine inspections as part of the system's overall maintenance schedule. Any issues with temperature regulation should be investigated promptly to prevent system inefficiencies or damage.

Frequently asked questions

Can the AVANSA Adex midi be used with a boiler that has no built-in controls?
No, the AVANSA Adex midi is designed for use with boilers that already have built-in time and temperature controls. It does not provide boiler control functions and requires the boiler to be managed separately.

Does the AVANSA Adex midi control the circulation pump?
No, the AVANSA Adex midi does not control the circulation pump. It is designed to regulate the mixing valve only and must be used in conjunction with a separate pump control system.

Can the AVANSA Adex midi be used with a thermal storage tank?
Yes, the AVANSA Adex midi is suitable for use with systems that include thermal storage tanks. It helps regulate the temperature of the return water to ensure efficient heat distribution.

What accessories are required for the AVANSA Adex midi?
An external temperature sensor is required for the AVANSA Adex midi to function correctly. This sensor must be ordered separately and installed according to the manufacturer's instructions.

Additional parameters

Category: Thermostats, pumps and boiler room equipment
Warranty: 2 years
Weight: 1 kg