Wood-burning and multifuel boilers require durable and thermally stable components to ensure long-term performance. The lower chamber of such boilers is exposed to high thermal stress and must maintain structural integrity under varying combustion conditions. This spherical chamber is specifically designed for the Atmos DC100 and DC70GSX models, where it forms a critical part of the combustion chamber assembly. It is used in residential and commercial heating systems where solid fuel boilers are integrated into central heating networks. The chamber is installed during boiler assembly or as a replacement part when wear or damage occurs.

Installers working with Atmos boilers must ensure that all components are correctly aligned and securely fastened. The chamber is part of a larger assembly that includes side panels, a rear panel, and extension pieces. The modular design allows for precise fitting and ensures that the chamber maintains its shape and function under thermal expansion. The chamber is installed in the lower section of the boiler, where it supports the combustion process and helps manage heat distribution within the chamber.

Technical parameters

Length690mm (510mm + 180mm extension)
Weight9999 kg
CodeC0035
BrandAtmos
The total length of the chamber is 690mm, consisting of a base section of 510mm and an extension of 180mm. This modular design allows for flexibility in installation and replacement. The length is a key factor in ensuring compatibility with the boiler model and chamber depth. The chamber is designed to fit into an 800mm deep chamber, which is a critical dimension for correct installation and performance.

Installation and connection

The installation process involves fitting the left and right side panels (C0062 and C0063), the rear panel (DC0168), and two extension pieces (DC0099). Each component must be aligned and secured to form a complete spherical chamber. The assembly is then positioned within the lower chamber of the boiler. Installers should verify that all parts are present and correctly oriented. Common installation errors include misalignment of the extension pieces or incorrect fastening of the side panels. It is important to ensure that the chamber is fully seated and that there are no gaps or misalignments that could affect combustion efficiency or structural integrity.

Compatibility and accessories

This chamber is specifically designed for use with Atmos DC100 and DC70GSX boilers. It is not compatible with other models or chamber depths. When replacing the chamber, it is necessary to order all included components: left side (C0062), right side (C0063), rear panel (DC0168), and two extensions (DC0099). No additional products are required for installation. The chamber is supplied as a complete unit and is not sold as individual components.

Technical background for designers

The spherical chamber is constructed from ceramic material, which provides high thermal resistance and durability under repeated heating and cooling cycles. The ceramic material is chosen for its ability to withstand high temperatures without deforming or cracking. The chamber is integrated into the boiler's combustion system, where it supports the combustion process by maintaining a stable and uniform temperature within the chamber. The chamber's shape and material contribute to efficient heat transfer and help prevent localized overheating. The chamber's design also allows for even expansion and contraction, which is important for maintaining structural integrity over time.

Service and operation

Regular inspection of the chamber is recommended to ensure that there are no signs of wear, cracking, or misalignment. The chamber should be checked for any gaps or deformations that could affect combustion efficiency. If any damage is detected, the chamber should be replaced immediately to prevent further damage to the boiler. No specific service intervals are provided in the brief, but it is advisable to inspect the chamber during routine boiler maintenance. The chamber is not designed for partial repair and must be replaced as a complete unit if any damage is found.

Frequently asked questions

Can this chamber be used with other Atmos boiler models?
This chamber is specifically designed for the Atmos DC100 and DC70GSX models with an 800mm chamber depth. It is not compatible with other models or chamber depths.

Is the chamber supplied as a complete unit?
Yes, the chamber is supplied as a complete unit including left and right side panels, a rear panel, and two extension pieces. No additional components are required for installation.

What material is the chamber made of?
The chamber is constructed from ceramic material, which provides high thermal resistance and durability under repeated heating and cooling cycles.

Can the chamber be repaired if damaged?
No, the chamber is not designed for partial repair. If any damage is detected, the entire chamber must be replaced to ensure proper function and safety.

Additional parameters

Category: Spherical space for the lower chamber
Warranty: 2 years
Weight: 60.444 kg
Length: 690mm (510mm + 180mm extension)
Hmotnosť: 60,4 kg