Carbon monoxide (CO) sensor PNI HS282

Code: PNI-HS282
€9,10 / pcs €11,19 incl. VAT Measure price:
In stock at supplier

Detailed information

Product detailed description

Carbon monoxide (CO) detectors are essential components in modern safety systems, particularly in environments where combustion appliances such as boilers, stoves or heaters are in use. Installers commonly integrate these devices in homes, offices and commercial buildings to ensure early detection of potentially lethal CO leaks. The PNI SafeHouse HS282 is designed for wall mounting in areas with good air circulation, avoiding high-humidity zones like bathrooms or kitchens. It functions independently of mains power, relying instead on low-energy consumption and long-lasting AA batteries, making it suitable for retrofitting in existing structures or for use in temporary installations.

The HS282 is often deployed in multi-room or multi-storey buildings where comprehensive coverage requires multiple units. Its compact size and low-profile design allow for discreet placement while ensuring visibility and accessibility for routine checks. The device is not intended for outdoor use and should be installed away from direct sunlight or extreme temperatures to maintain sensor accuracy over time. The alarm threshold is set to activate at low CO concentrations, allowing occupants to evacuate safely before reaching hazardous levels.

Technical parameters

EAN5949066543807
Weight0.205 kg
CodePNI-HS282
The PNI HS282 uses an electrochemical sensor to detect CO levels between 0 and 999 parts per million (ppm). The alarm activates based on time-weighted thresholds depending on the concentration, such as 30 ppm over 30 minutes or 300 ppm immediately. The device consumes less than 10 microamps in standby mode and up to 25 milliamps during alarm activation, ensuring extended battery life. These parameters are critical for determining the suitability of the sensor for specific applications, especially when considering the frequency of testing and the expected operational lifespan of the batteries.

Installation and connection

The PNI HS282 is mounted on a wall using the included hardware. The location should be near potential sources of CO, such as furnaces or fireplaces, but not directly in their exhaust path. The device must be placed at a height where it can detect rising CO gas effectively. Avoid installing it in corners or behind furniture, as this may restrict airflow and reduce sensitivity. During installation, ensure the surface is clean and dry to prevent damage to the housing or interference with the sensor’s readings.

After mounting, the device undergoes a brief calibration process upon initial power-up. This step ensures accurate readings before the unit enters normal operation. A blinking LED indicates the device is functioning correctly. If the LED remains static or fails to blink, the installation should be reviewed for possible obstructions or incorrect positioning. Routine testing using the TEST/MUTE button is recommended to verify functionality, and any irregularities should be investigated immediately.

Compatibility and accessories

The PNI HS282 is a standalone device and does not require additional accessories for basic operation. However, for larger buildings or complex safety systems, multiple units may be needed to cover all relevant areas. No external power supply or control systems are required, making it compatible with most existing setups. The device is designed for use with standard AA batteries, which are not included in the package and must be sourced separately.

Technical background for designers

The HS282 employs an electrochemical sensor to detect CO molecules in the air. This type of sensor generates an electrical signal proportional to the concentration of CO present, which is then processed by the internal electronics to trigger alarms or display readings. The housing is made from durable plastic to resist environmental factors like dust and minor impacts. The device operates within a wide temperature range (-10°C to +55°C) and is suitable for both indoor and controlled environments.

The sensor’s response time and accuracy depend on ambient conditions such as humidity and air quality. High levels of dust or chemical vapours may interfere with readings, requiring periodic cleaning of the sensor housing. The device is designed for long-term use but has a finite lifespan, after which the sensor may no longer provide reliable results. Designers should consider these factors when planning for replacement cycles and system redundancy in critical applications.

Service and operation

Regular maintenance of the PNI HS282 includes visual inspections for physical damage, cleaning the exterior with a soft cloth to remove dust or debris, and testing the alarm function using the TEST/MUTE button. The device provides visual and auditory signals when the battery is low or when the sensor is nearing the end of its operational life. These signals help technicians identify when a unit needs servicing or replacement. No scheduled service intervals are defined in the technical documentation, but users are advised to perform tests periodically to ensure continued reliability.

If the alarm activates unexpectedly, the area should be ventilated and the source of CO investigated. The device should not be used beyond its specified operating conditions, and any signs of malfunction must be addressed promptly. The battery compartment should be checked for corrosion or leakage, and the unit should be replaced entirely if the housing shows signs of wear or damage that could affect performance.

Frequently asked questions

Can the PNI HS282 be integrated into a central monitoring system?
No, the device is designed as a standalone CO detector and does not support integration with external control or monitoring systems.

How does the device indicate low battery power?
A specific pattern of flashing LED and an intermittent alarm sound alerts users to replace the batteries.

Is the PNI HS282 suitable for industrial environments?
The device is intended for residential and commercial use only and is not certified for industrial or high-risk environments.

What should be done if the alarm activates but no CO is detected?
Evacuate the area and ventilate it thoroughly. Test the device using the TEST/MUTE function to confirm its functionality and investigate the cause of the false alarm.

Additional parameters

Category: Detectors
Weight: 0.205 kg
EAN: 5949066543807