MHPower MPU-1050-24 - USED, UPS, 1050W, pure sine, 24V
Code: ABCT_A500003753Product detailed description
This backup power supply has been in use for approximately 4 months. This is a fully functional product, sold with a 24 month warranty. The backup power supply is clean, undamaged, lightly scratched from normal use. Sold complete in slightly torn original packaging.
UPS MHPower MPU-1050 is ideal as a backup source for a circulation pump, as a backup source for a boiler or as a backup source for a fireplace stove. However, thanks to its clean output sine curve and robust toroidal transformer, it is also suitable for backing up many other devices such as household appliances, power tools, chargers, compressors, pumps, motors, electric drives, office equipment, television equipment, telecommunications, servers, PCs and other powered devicesup to 1050Wcontinuous operation. The backup power supply can be used for example as a UPS for a caravan. The biggest advantage of this power supply is the possibility of connecting an external battery (not included in the device), thanks to which it is able to power the connected appliances for a long time, depending on the selected battery capacity, see the table with the approximate backup time.
Features:
When the mains power is supplied, the connected appliances are powered directly from the mains, the external battery is recharged, when the mains fails, the power supply automatically switches to the voltage converter, energy is drawn from the battery, the appliances are powered from the converter. When power is restored, the power supply automatically switches to the mains, the battery starts to recharge. WARNING: There is no backup battery inside the backup power supply. In order for this backup power supply to perform its function, it is necessary to purchase an external battery, which is not included. Without this external battery, the device is unable to operate.
Please read our article carefully before buying a voltage converter:
How to choose the right voltage converter?
Technical parameters:
Maximum rated power: 1050W
Battery voltage 24 V
Charging current: 10 or 15 A (Optional)
Charging voltage: 27.2V+/-0.6V
Low voltage limit: 21.8+-0.6V
Low voltage protection: 20.5+-0.6V
High voltage protection: 31.5V ±0.5V
AC input frequency: 45 Hz ~ 65 Hz
Switching time to backup: 4ms
Inverter consumption without load:max. 20W
Output voltage range of AVR voltage regulator: from domestic mains 204 - 240 V, inverter 230 V (+ - 3%)
UPS output voltage frequency 50 Hz (+ - 0.5 Hz)
Overload protection (battery power): in the event of an overload of 110% - 130% of the power, the output will be switched off within 30 seconds. If the overload is greater than 130%, the power to the output will be interrupted immediately.
Overload protection (mains power): the device warns against overload until the fuse blows.
Physical characteristics:
Operating humidity 10% RH ~ 90% RH
Operating temperature 0~40°C
Product dimension: 350 mm x 145 mm x 210 mm
Dimensions of the transport case: 410 mm x 195 mm x 270 mm
Product weight: 7.7 kg
Shipping package weight: 0.5 kg
Total weight: 8.2 kg
Colour: black
Product Description:
We recommend this backup power supply for its flexible use. Pure sine wave output. Ideal for long-term backup.
Maximum continuous power 1050W
Integrated charger 10/15 A max
Robust all-metal design
Cables for external battery connection 0.8m
Automatic switchover in case of mains failure, automatic recharging of external battery
Recommended battery capacity: 40-250Ah (batteries below 60Ah are recommended to be charged with a lower current of 10A)
Supported batteries: GEL, AGM, classic flooded
Not supported batteries: Li-on, Li-Pol, LiFePO, etc.
Compact dimensions
ATTENTION! The backup power supply (UPS) only works when connected to an external battery. It should not be used without a battery connected. When the battery is connected, plug the main power cord into a mains socket (230V, 50 Hz) with a mains earth connection. On the back of the power supply, connect the device you want to operate during a power failure.Follow the following procedure: connect the battery, connect the main power supply, and then connect the appliance(s) to the backup power supply (UPS). To switch the AC load (appliance sockets) on or off, press and hold the power button (ON/OFF) for about 2 seconds.
In the event of a power failure or if the power parameters are not within the normal range, the backup power supply (UPS) automatically switches to the battery. The switching of the UPS to the battery is shown on the UPS display. The UPS device also announces the switching of the UPS to the battery with an audible signal.
Additional parameters