Oil pump AOP-55 assembly complete
Code: PR_40065Related products
Product detailed description
Oil pumps are essential in industrial and commercial settings where the transfer of viscous or non-viscous liquids is required. The IBO AOP-55 complete assembly is commonly used in fuel storage and distribution systems, maintenance workshops, and industrial facilities. Installers and technicians working in these environments often deal with the need to move oil or diesel from one container to another, either for refilling, draining, or transferring between storage tanks. The AOP-55 is suited for applications where a high flow rate and sufficient pressure are necessary to overcome system resistance and elevation differences.
When installing such a system, it is important to consider the physical layout of the installation site, the viscosity of the fluid being transferred, and the required flow rate. The pump must be mounted in a location that allows for easy access to the suction and discharge points, and the hoses must be routed without kinks or obstructions. The AOP-55 is designed for use with standard oil and diesel, and its components are selected to ensure compatibility with these media. The pump is suitable for intermittent operation and should be installed with proper support to avoid mechanical stress on the motor or pump housing.
Technical parameters
| EAN | 5903137510150 |
|---|---|
| Length of supply cable (m) | 1 |
| Maximum flow rate (l/min) | 55 |
| Pump type - voltage (V) | 230 V |
| Pump head (m) | 15 |
| Code | PR_40065 |
| Brand | IBO |
Installation and connection
The installation of the IBO AOP-55 requires careful planning to ensure reliable operation. The pump should be mounted on a stable, level surface to prevent vibration and misalignment. The suction hose must be connected to the pump inlet using a compatible thread type, and the discharge hose with spray gun must be connected to the outlet. The 1 m supply cable should be routed to a suitable power source, ensuring that the voltage matches the pump’s requirements. Installers should verify that the hose connections are secure and leak-free, and that the pump is not installed in a location where it could be exposed to excessive heat or moisture.
Common installation mistakes include using incompatible hose fittings, failing to support the hoses properly, and neglecting to check the electrical connection for correct polarity. It is also important to ensure that the pump is not operated dry, as this can cause damage to the internal components. A check valve may be added to the discharge line to prevent backflow in certain applications.
Compatibility and accessories
The IBO AOP-55 is compatible with standard oil and diesel storage and transfer systems. It is designed for use with non-aggressive, non-corrosive fluids and is not suitable for highly viscous or abrasive media. The pump is supplied with a complete set of hoses and fittings, but additional components such as filters, valves, or mounting brackets may be required depending on the specific installation. Installers should ensure that all components are compatible with the fluid being transferred and that the system is properly sealed to prevent leaks.
Technical background for designers
The IBO AOP-55 operates on a centrifugal or positive displacement principle, depending on the internal design of the pump. The motor drives the pump mechanism, which creates a pressure differential to move the fluid from the suction side to the discharge side. The materials used in the construction of the pump are selected for their resistance to oil and diesel, ensuring long-term durability. The pump is integrated into the system through standard hose connections, and its performance is influenced by factors such as fluid viscosity, temperature, and the presence of air in the suction line. Proper system design should account for these variables to ensure efficient and reliable operation.
Service and operation
Regular inspection of the IBO AOP-55 is recommended to ensure continued performance. Installers should check for signs of wear on the hoses, verify the tightness of all connections, and ensure that the pump is operating without unusual noise or vibration. The electrical connection should be inspected for damage or corrosion. As the brief does not specify service intervals, it is advisable to follow the manufacturer’s recommendations for maintenance. In the event of a malfunction, the pump should be disconnected from the power source before any inspection or repair work is carried out.
Frequently asked questions
Can the IBO AOP-55 be used for transferring other types of oil besides diesel?
The pump is suitable for standard oil and diesel. It is not recommended for highly viscous or abrasive media.
Is the pump supplied with all necessary components for immediate use?
The pump is supplied with a suction hose, discharge hose with spray gun, and a 1 m supply cable.
What is the maximum height the pump can lift the fluid?
The pump can lift the fluid up to 15 m against gravity.
Can the pump be mounted in any orientation?
The pump should be mounted on a stable, level surface to prevent mechanical stress and ensure proper operation.
Additional parameters
| Category: | Pumps for oil |
|---|---|
| Weight: | 2.5 kg |
| EAN: | 5903137510150 |
| Max. head: | 9 – 20 m |
| Voltage: | 230 V |
| Maximum flow rate (l/min): | 55 |
| Pump delivery head (m): | 15 |
| Pump version - voltage (V): | 230 V |
| Supply cable length (m): | 1 |
| EAN: | 5903137510150 |
Discussion