Oil pump AOP-55
Code: PR_40060Related products
Product detailed description
The AOP-55 oil pump is commonly used in industrial and commercial settings where the transfer of oil or fuel is required. It is suitable for integration into heating systems, fuel storage facilities, and water supply systems where viscous media need to be moved efficiently. The pump is typically installed in environments where a stable electrical supply is available and where the media being transported is non-corrosive and non-abrasive. It is often used in conjunction with fuel tanks, storage reservoirs, and transfer lines to ensure continuous and controlled flow.
Installers and technicians working with this pump are typically involved in the maintenance of heating systems, fuel supply infrastructure, and industrial fluid handling. The AOP-55 is designed for use in closed-loop systems and can be integrated into existing piping configurations with minimal modifications. It is important to ensure that the pump is installed in a location that allows for easy access for maintenance and inspection, and that the surrounding environment is free from excessive moisture or vibration.
Technical parameters
| EAN | 5903137510150 |
|---|---|
| Supply cable length (m) | 1 |
| Maximum flow rate (l/min) | 55 |
| Pump voltage (V) | 230 V |
| Pump head (m) | 15 |
| Weight | 2 kg |
| Code | PR_40060 |
| Brand | IBO |
Installation and connection
Installation of the AOP-55 involves securing the pump in a stable position and connecting it to the inlet and outlet piping. The pump should be mounted in a horizontal orientation to ensure proper operation. The inlet and outlet connections are threaded and must be verified for compatibility with the existing piping system. A non-return valve is recommended on the outlet side to prevent backflow and potential damage to the pump.
Before energising the pump, the installer should check for correct alignment of the inlet and outlet, the integrity of the electrical connections, and the absence of air pockets in the system. Common installation errors include incorrect orientation, insufficient support for the pump body, and failure to install a pressure gauge for monitoring system performance. It is also important to ensure that the pump is not operated dry, as this can cause internal damage.
Compatibility and accessories
The AOP-55 is compatible with standard fuel and oil transfer systems and can be integrated with a variety of control systems, including pressure switches and flow meters. It is recommended to use compatible piping materials such as stainless steel or high-density polyethylene to ensure long-term durability. Additional accessories such as filters, strainers, and flow control valves may be required depending on the specific application and media properties.
For installations requiring remote monitoring or control, the pump can be connected to a control panel or programmable logic controller (PLC). No specific related products are listed for this model, but the pump should be selected in conjunction with system components that match its flow and pressure capabilities.
Technical background for designers
The AOP-55 operates on the principle of centrifugal pumping, where the impeller generates kinetic energy to move the fluid through the system. The pump is constructed from materials that are resistant to the effects of oil and fuel, ensuring long-term reliability. The design allows for efficient transfer of viscous media without excessive wear or energy consumption.
When integrating the pump into a system, designers should consider the viscosity of the fluid, the required flow rate, and the system pressure. The pump's performance is influenced by the condition of the inlet and outlet piping, the presence of bends or restrictions, and the overall system layout. Proper sizing and positioning of the pump are critical to achieving optimal performance and minimising energy losses.
Service and operation
Regular inspection of the pump is recommended to ensure continued performance. The electrical connections should be checked for signs of wear or overheating, and the inlet and outlet piping should be inspected for blockages or leaks. No specific service intervals are provided in the brief, but it is advisable to follow the manufacturer's guidelines for maintenance and lubrication of moving parts.
During operation, the pump should be monitored for unusual noise, vibration, or changes in flow rate, which may indicate the need for servicing. It is important to ensure that the pump is not operated under conditions that exceed its rated capacity, as this can lead to premature failure.
Frequently asked questions
Can the AOP-55 be used for the transfer of diesel fuel?
Yes, the pump is suitable for the transfer of oil and fuel, including diesel, provided the media is non-corrosive and within the pump's operating parameters.
Is the AOP-55 compatible with 230 V electrical systems?
Yes, the pump is designed for 230 V operation, making it suitable for standard electrical installations in most European countries.
What is the maximum flow rate of the AOP-55?
The pump has a maximum flow rate of 55 l/min, which is suitable for applications requiring moderate to high fluid transfer rates.
Can the AOP-55 be installed in a vertical orientation?
It is recommended to install the pump in a horizontal orientation to ensure proper operation and prevent mechanical stress on the components.
Additional parameters
| Category: | Pumps for oil |
|---|---|
| Weight: | 2 kg |
| EAN: | 5903137510150 |
| Max. head: | 9 – 20 m |
| Voltage: | 230 V |
| Maximum flow rate (l/min): | 55 |
| Pump delivery head (m): | 15 |
| Pump version - voltage (V): | 230 V |
| Supply cable length (m): | 1 |
| EAN: | 5903137510150 |
Discussion