Surface self-priming pump IBO AJ
Code: PR_38743Related products
Product detailed description
The IBO AJ surface self-priming pump is commonly used in residential and commercial buildings for water circulation in heating and plumbing systems. It is typically installed in basements, utility rooms, or dedicated mechanical spaces where access to the pump is required for maintenance and inspection. The pump is suitable for closed-loop systems, such as underfloor heating, domestic hot water circulation, and small-scale irrigation systems. Installers should ensure that the pump is mounted on a stable, level surface to prevent vibration and misalignment. The pump must be connected to a power supply and integrated into the system piping with appropriate fittings and valves to control flow and pressure.
When installing the pump, it is important to consider the system's hydraulic requirements, including the required flow rate and head. The pump is designed to handle typical water temperatures and flow conditions found in heating and plumbing applications. It is not suitable for pumping abrasive or chemically aggressive media. The pump must be installed in accordance with local regulations and manufacturer guidelines to ensure safe and efficient operation. The pump's compact dimensions make it suitable for installations with limited space, and the included power cable allows for flexible positioning near the power source.
Technical parameters
| EAN | 5903887210072 |
|---|---|
| Length of power cable (m) | 1 |
| Maximum flow rate (l/min) | 60 |
| Pump voltage (V) | 230 V |
| Dimensions H x W x D (cm) | 37x21x20 |
| Pump head (m) | 50 |
| Code | PR_38743 |
| Brand | IBO |
Installation and connection
Installation of the IBO AJ pump should begin with verifying the system's hydraulic requirements and ensuring that the pump is compatible with the existing piping and fittings. The pump should be mounted on a stable, level surface to prevent vibration and misalignment. The inlet and outlet connections must be aligned with the system piping, and appropriate fittings should be used to ensure a secure and leak-free connection. The pump's power cable must be connected to a suitable electrical supply, and the connection should be made in accordance with local electrical codes. It is important to check the pump's direction of rotation to ensure that it is operating correctly. Common installation mistakes include incorrect alignment of the pump, failure to secure the electrical connection, and improper mounting, which can lead to vibration, noise, and reduced efficiency.
Compatibility and accessories
The IBO AJ pump is compatible with standard water systems and can be integrated into heating and plumbing circuits with appropriate fittings and valves. It is typically used in conjunction with pressure gauges, flow meters, and control valves to monitor and regulate system performance. Additional accessories that may be required include expansion vessels, pressure switches, and check valves to prevent backflow and maintain system pressure. The pump is not compatible with systems requiring chemical resistance or high-temperature operation. Installers should ensure that all components are compatible with the pump's specifications and that the system is properly balanced to avoid overloading the pump.
Technical background for designers
The IBO AJ pump operates on the principle of self-priming, which allows it to draw water from a source without the need for external priming. The pump's impeller is designed to create a vacuum that draws water into the pump chamber and forces it through the outlet. The pump is constructed from durable materials that are suitable for use with clean water and standard plumbing applications. The pump's compact design and efficient operation make it suitable for integration into a variety of systems, including underfloor heating, domestic hot water circulation, and small-scale irrigation. The pump's performance is influenced by factors such as the system's hydraulic resistance, the temperature of the water, and the presence of air in the system. Proper system design and installation are essential for ensuring the pump's long-term reliability and efficiency.
Service and operation
The IBO AJ pump requires regular inspection and maintenance to ensure continued performance and reliability. Installers should check the pump's electrical connections, inlet and outlet fittings, and impeller for signs of wear or damage. The pump should be inspected for leaks, vibration, and unusual noise, which may indicate a problem with the system or the pump itself. The pump's power cable should be checked for damage, and the electrical connection should be verified to ensure that it is secure and functioning correctly. There are no specified service intervals for this pump, but regular inspection is recommended to identify and address potential issues before they lead to system failure.
Frequently asked questions
Can the IBO AJ pump be used in a closed-loop heating system?
Yes, the IBO AJ pump is suitable for use in closed-loop heating systems, provided that the system's hydraulic requirements match the pump's specifications.
What is the maximum temperature of the water that the pump can handle?
The pump is designed for use with clean water at standard temperatures, but the maximum operating temperature is not specified in the technical data.
Can the pump be installed in a vertical position?
The pump is designed for horizontal installation on a stable, level surface. Vertical installation is not recommended, as it may affect the pump's performance and longevity.
Is the pump suitable for use with a variable speed drive?
The pump is designed for fixed-speed operation on a 230 V supply. It is not specified whether it is compatible with variable speed drives.
Additional parameters
| Category: | Self-priming water pumps |
|---|---|
| Warranty: | 2 years |
| Weight: | 11 kg |
| EAN: | 5903887210072 |
| Pump application: | garden / self-priming |
| Max. head: | 21 – 50 m |
| Voltage: | 230 V |
| Dimensions H x W x D (cm): | 37x21x20 |
| Maximum flow rate (l/min): | 60 |
| Pump delivery head (m): | 50 |
| Pump version - voltage (V): | 230 V |
| Supply cable length (m): | 1 |
| EAN: | 5903887210072 |