Wholesale e-shop

Siemens Heat Meter 0,6m3/h

Code: WFM501-E000H0
–5 %
Vykurovacia technika Siemens Merač tepla 0,6m3/h
–5 % €151,80 / pcs €186,71 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

The Siemens WFM501-E000H0 heat meter is commonly used in residential and commercial heating systems where accurate measurement of thermal energy is required. It is typically installed in the return line of a heating circuit to monitor and record heat consumption over time. The device is suitable for low-temperature systems and is often found in applications such as district heating, individual building heating, and industrial process heating. Installers and service technicians use this meter to ensure accurate billing and system performance evaluation. The compact design and long battery life make it ideal for installations where access is limited and maintenance is infrequent.

Its mechanical flow measurement principle and IrDA communication interface allow for integration with data collection systems without the need for additional wiring. The device is designed for use in closed-loop water-based heating systems and is compatible with standard pipe configurations. It is not intended for high-pressure or high-temperature steam systems.

Technical parameters

Weight5 kg
CodeWFM501-E000H0
BrandSIEMENS
The heat meter is rated for a maximum flow rate of 0.6 m3/h, with a minimum flow of 0.012 m3/h and a maximum of 1.2 m3/h. These values are critical for determining the suitability of the meter for a given system. The 10-year battery life ensures long-term operation without the need for frequent replacements. The 36-second temperature measurement cycle is suitable for most low-temperature heating applications. These parameters should be considered during system design to ensure compatibility with the expected flow and energy demand.

Installation and connection

The Siemens WFM501-E000H0 is installed in the return pipe of a heating system. It requires a G 3/4" connection, and the installation should be carried out in accordance with the manufacturer's guidelines. The meter should be mounted in a straight section of pipe, with sufficient clearance upstream and downstream to ensure accurate flow measurement. The sensor cables are 1.5 m in length, so the control unit must be positioned within this range. Common installation mistakes include incorrect orientation, insufficient straight pipe length, and failure to check for air pockets or blockages in the pipe before fitting the meter. It is essential to verify that the system is depressurised and drained before installation to prevent damage to the device.

Compatibility and accessories

The WFM501-E000H0 is compatible with standard heating systems that use water as the heat transfer medium. It is recommended to use installation kits such as the HMXI-K series to ensure proper mounting and sealing. These kits typically include mounting brackets, sealing rings, and other necessary components. The heat meter is designed to replace models from the WFM407 and WFN2 series, making it a suitable upgrade option for existing installations. No additional power supply is required due to the battery-powered design. However, it is important to ensure that the control system or data logger is compatible with the IrDA communication interface for seamless data transfer.

Technical background for designers

The Siemens WFM501-E000H0 operates using a mechanical vane meter to measure flow rate. The device calculates heat consumption by combining the measured flow with temperature differences between the supply and return lines. The meter is constructed from durable materials suitable for use in water-based heating systems. The battery-powered design eliminates the need for electrical wiring, making it suitable for retrofitting into existing systems. The integration into the system is achieved through the IrDA interface, which allows for wireless data transmission to a central monitoring unit. The service life of the meter is influenced by the quality of the installation, the presence of impurities in the water, and the frequency of flow fluctuations. Proper system balancing and filtration can help extend the device's operational life.

Service and operation

The Siemens WFM501-E000H0 requires minimal maintenance due to its battery-powered and mechanical design. The 10-year battery life means that no service is required for this component during normal operation. However, it is recommended to periodically inspect the device for signs of corrosion, blockages, or damage to the housing. The meter should be checked for proper alignment and secure mounting to ensure accurate readings. No scheduled service intervals are specified in the technical data. If the device is removed for any reason, the installation should be repeated following the same guidelines to maintain measurement accuracy.

Frequently asked questions

Can the Siemens WFM501-E000H0 be used in high-temperature systems?
No, the device is designed for low-temperature water-based heating systems and is not suitable for high-temperature or steam applications.

Is the battery in the WFM501-E000H0 replaceable?
Yes, the battery has a 10-year life and can be replaced when necessary, following the manufacturer's guidelines.

What is the minimum flow rate for accurate measurement?
The minimum measurable flow is 0.012 m3/h, which is suitable for most low-flow heating applications.

Can the WFM501-E000H0 be integrated with a building management system?
Yes, the IrDA communication interface allows for wireless data transmission, making it compatible with most building management and monitoring systems.

Additional parameters

Category: Siemens
Warranty: 2 years