Wholesale e-shop

Wi-Fi methane gas sensor (CH4) PNI HS201

Code: PNI-HS201
€28,60 / pcs €35,18 incl. VAT Measure price:
In stock at supplier

Detailed information

Product detailed description

The PNI SafeHouse HS201 is a plug-in gas detection device intended for environments where natural gas (CH4) or liquefied petroleum gas (LPG) is used. It is commonly installed in kitchens, utility rooms, and industrial settings where gas leaks pose a risk. The device is designed for use in both residential and commercial applications, where early detection of gas leaks is critical for safety. Installers typically encounter this type of device in new builds, renovations, or as part of retrofitting safety systems in existing properties. The PNI HS201 is particularly suited for environments where remote monitoring and integration with smart home systems are required.

As a fixed, mains-powered device, the PNI HS201 eliminates the need for battery replacements and ensures continuous operation. It is not intended for outdoor use or in areas with high humidity or extreme temperatures. The device is designed to detect gas leaks and trigger alarms locally and remotely, making it a key component in comprehensive building safety systems.

Technical parameters

EAN5949066534270
Weight0.188 kg
CodePNI-HS201

The technical parameters of the PNI HS201 include a detection threshold of 6% LEL (±3%) for CH4 and LPG. This level is set to ensure early warning before concentrations reach dangerous levels. The device operates on a wide voltage range (100–240 V AC), making it suitable for use in various European electrical systems. The 70 dB alarm ensures audibility in most indoor environments, while the Wi-Fi connectivity at 2.4 GHz allows for integration with smart home platforms. These parameters are essential for determining the suitability of the device for specific installation environments.

Installation and connection

Installation of the PNI HS201 involves connecting the device to a standard 230 V AC socket, ensuring it is positioned at a sufficient distance from potential gas sources. The device must be mounted securely and in a location free from obstructions that could interfere with gas flow to the sensor. The alarm is triggered when gas concentration reaches 8% LEL, and it remains active until the concentration drops below 4%, with a 1-minute delay before returning to normal operation.

Common installation mistakes include placing the detector too close to gas appliances, which can lead to false alarms, or in areas with poor ventilation, which may delay detection. Installers should also ensure that the device is not installed in direct sunlight or near heat sources, as these can affect sensor performance. The device must be connected to a stable Wi-Fi network for remote monitoring and control via the Tuya Smart app.

Compatibility and accessories

The PNI HS201 is compatible with the Tuya Smart app, allowing for remote monitoring and control. It can also be integrated with other smart home devices, such as Wi-Fi solenoid valves, to create automated safety scenarios. For example, a gas leak can trigger the valve to close automatically, preventing further gas accumulation. No additional accessories are required for basic operation, as the device is supplied with a user manual and no other components.

Technical background for designers

The PNI HS201 operates using a catalytic combustion sensor to detect combustible gases such as CH4 and LPG. The sensor reacts to the presence of gas by increasing the temperature of a catalytic element, which is then measured and compared to a reference point. This method is highly reliable and minimizes the risk of false alarms. The device is constructed with durable materials to ensure long-term stability in indoor environments. The Wi-Fi module allows for real-time data transmission to the Tuya Smart app, enabling remote monitoring and control.

Integration into a building’s safety system requires a stable electrical supply and a compatible Wi-Fi network. The device’s low power consumption (≤3 W) ensures minimal impact on overall system load. The 2.4 GHz frequency band is widely used in smart home systems, ensuring compatibility with most modern devices. The device’s design and operating principle ensure a long service life, provided it is installed and maintained according to the manufacturer’s guidelines.

Service and operation

The PNI HS201 requires no regular maintenance beyond routine checks to ensure it is functioning correctly. Installers should verify that the device is connected to a stable power source and that the Wi-Fi signal is strong enough to maintain a consistent connection. The alarm should be tested periodically to confirm that it activates at the correct threshold and that the visual and audible signals are functioning properly.

During operation, the device continuously monitors the surrounding air for gas. If a leak is detected, the alarm is triggered, and a notification is sent to the Tuya Smart app. The device automatically resets once the gas concentration drops below 4%, after a 1-minute delay. No manual service intervals are specified in the product documentation, and the device is designed for continuous operation without the need for user intervention.

Frequently asked questions

Can the PNI HS201 be connected to a smart home system?
Yes, the PNI HS201 is compatible with the Tuya Smart app, which allows for remote monitoring and control. It can also be integrated with other smart devices, such as solenoid valves, to create automated safety responses.

What is the power supply requirement for the PNI HS201?
The device operates on 100–240 V AC, making it suitable for use in most European electrical systems. It is designed for plug-in installation and does not require a separate power supply.

How does the PNI HS201 trigger an alarm?
The alarm is triggered when gas concentration reaches 8% LEL. The device activates a visual alarm (LED), an audible alarm (≥70 dB), and sends a notification to the Tuya Smart app. The alarm remains active until the concentration drops below 4%, with a 1-minute delay before resetting.

Can the PNI HS201 detect other gases besides CH4 and LPG?
The PNI HS201 is specifically designed to detect CH4 and LPG. It is not suitable for detecting other types of gases, such as carbon monoxide or hydrogen sulfide.

Documents for download

Additional parameters

Category: Detectors
Weight: 0.188 kg
EAN: 5949066534270
Availability: In stock or at supplier

PNI-HS201