Zone valve 230V DN20
Code: F14203Related products
Product detailed description
This 230V DN20 zone valve is commonly used in heating systems for zoned temperature control in residential and commercial buildings. It is typically installed in systems where individual zones require independent regulation, such as in multi-room heating setups or in larger properties with separate heating circuits. The valve operates in conjunction with thermostats and control systems to manage the flow of heating media, ensuring efficient and targeted heat distribution. Installers working on central heating systems, especially those involving underfloor heating or multi-loop radiators, will find this valve suitable for integration into existing or new installations.
Correct installation of the valve is critical to ensure reliable operation and system efficiency. The valve is designed for use with non-aggressive fluids and is suitable for systems with glycol content below 50%. It is also compatible with potable water systems, making it versatile for a range of applications. The FF connection allows for straightforward integration into standard piping systems, and the 230V 50Hz power supply ensures compatibility with standard electrical infrastructure in European installations.
Technical parameters
| Rotation time | 12s/90°C |
|---|---|
| Control options | Manually/Automatically |
| Voltage | 230V 50Hz |
| Connection type | FF |
| Ambient temperature | +55°C |
| Media temperature range | +2°C to +110°C |
| Code | F14203 |
Installation and connection
Installation of the DN20 zone valve requires careful attention to the connection type and system compatibility. The FF (female-female) connection allows for direct coupling with standard piping, using appropriate fittings and seals to prevent leaks. The valve should be installed in a position that allows for easy access for maintenance and manual override. It is important to ensure that the electrical supply is correctly wired and that the control system is properly integrated with the valve’s actuator.
Common installation mistakes include incorrect orientation of the valve, which can affect flow direction and performance, and failure to secure the electrical connections properly, which can lead to operational issues. Installers should also verify that the system pressure does not exceed PN 10 and that the media being used is within the specified temperature and chemical compatibility limits.
Compatibility and accessories
This zone valve is designed to work with standard heating system components, including thermostats, controllers, and actuators. It is compatible with systems using glycol-based media with a concentration below 50% and is suitable for potable water applications. When installing, it may be necessary to order additional components such as mounting brackets, sealing rings, or control modules, depending on the system configuration. No specific related products are listed for this model.
Technical background for designers
The valve operates using an electric actuator that opens and closes the valve in response to control signals. The actuator is powered by a 230V 50Hz supply and is designed to provide precise control over the flow of heating media. The valve body is constructed to handle media temperatures up to +110°C and is suitable for use in systems with glycol content below 50%. The FF connection ensures compatibility with standard piping systems and allows for secure, leak-free installation. The valve’s performance is influenced by the system pressure, media type, and ambient temperature, all of which should be considered during the design phase to ensure long-term reliability and efficiency.
Service and operation
Regular inspection of the valve is recommended to ensure continued performance. This includes checking the electrical connections for signs of wear or damage and verifying that the valve operates smoothly in both manual and automatic modes. The FF connection should be inspected for leaks or signs of corrosion, particularly in systems using glycol-based media. No specific service intervals are provided in the technical data, but it is advisable to perform routine checks in accordance with standard maintenance practices for heating system components.
Frequently asked questions
Can the valve be used in systems with glycol content above 50%?
No, the valve is only suitable for systems with glycol content below 50% as specified in the technical data.
Is the valve compatible with potable water systems?
Yes, the valve is suitable for use in potable water systems according to the manufacturer’s specifications.
Can the valve be controlled manually?
Yes, the valve supports both manual and automatic control modes, allowing for override in case of system failure or during installation.
What is the maximum ambient temperature for the valve?
The valve is rated for ambient temperatures up to +55°C, beyond which additional cooling or insulation may be required.
Additional parameters
| Category: | Servo drives and valves |
|---|---|
| Warranty: | 2 years |
| Nominal size (DN): | DN 20 |
| Ambient temperature: | +55°C, |
| Connection: | FF |
| Control options: | manual/automatic, |
| Heating medium temperature: | +2°C to + 110°C, |
| Rotation time: | 12s/90°C, |
| Voltages: | 230V 50Hz, |
Discussion
Be the first who will post an article to this item!