ATMOS DC 50 S
Code: DC50SProduct detailed description
The ATMOS DC50S is a robust wood-fired boiler engineered for long-term, stable operation in commercial and industrial heating applications. It is typically installed in larger buildings such as workshops, agricultural facilities, or multi-room residential structures where continuous heat generation is required. The boiler integrates into closed-loop water-based heating systems and can operate with radiators, underfloor heating, or buffer tanks. Installers should ensure proper chimney draft and flue gas routing to maintain combustion efficiency.
As a gasification boiler, the DC50S relies on staged combustion and secondary air injection to maximise fuel utilisation. This design reduces emissions while extending burn times between refuels. The system is suited for areas with ready access to seasoned firewood meeting the required specifications. Operators benefit from reduced ash removal frequency and minimal system downtime during routine maintenance.
Technical parameters
| Water volume | 89 L |
|---|---|
| Boiler weight | 433 kg |
| Maximum wood length | 730 mm |
| Minimum return water temperature | 65 °C |
| Fuel chamber capacity | 180 dm³ |
| Prescribed fuel | Dry wood with calorific value 15 – 18 MJ/kg, diameter 80 – 150 mm and moisture 12 -20 % |
| Required chimney draft | 25 Pa |
| Energy efficiency class | A+ |
| Combustion class | 4 |
| Power | 49,9 kW efficiency 87,7% |
| Code | DC50S |
| Brand | Atmos |
Installation and connection
Begin by verifying the chimney draft meets the specified 25 Pa requirement using a manometer. The boiler connects to the heating circuit via standard threaded ports; confirm flange or pipe dimensions match the existing system layout. Ensure the exhaust flue is correctly aligned with the chimney outlet and sealed to avoid leakage. Check the fuel chamber door mechanism and air control valves for smooth operation before commissioning. Avoid overloading the boiler beyond its rated capacity to prevent premature wear.Compatibility and accessories
The DC50S is compatible with standard steel or cast iron radiators, buffer tanks, and circulator pumps. An external chimney with a certified 25 Pa draft is essential for optimal performance. Additional components such as a room thermostat or programmable controller can enhance user convenience but are not included. Installers should also consider a separate fuel storage area due to the large fuel chamber size.Technical background for designers
The DC50S operates via generator gasification, where primary combustion produces volatile gases that are then burned in a secondary chamber. The boiler body is constructed from thick-walled steel plates (3–8 mm) for durability. Keramic refractory bricks line the combustion chamber, providing insulation and promoting complete fuel combustion. The cooling circuit prevents overheating of internal components, ensuring long-term reliability. System integration requires careful balancing of flow rates and return temperatures to maintain efficiency.Service and operation
Periodic checks include inspecting the exhaust system for blockages, cleaning the fuel feed opening, and verifying the operation of the exhaust fan. The large combustion chamber allows ash removal once per week under normal conditions. Monitor the exhaust temperature regularly to detect potential inefficiencies early. Replace damaged refractory bricks or worn-out gaskets immediately to avoid performance degradation.Frequently asked questions
Can the DC50S be integrated into an existing heating system?
Yes, provided the system meets the minimum return water temperature of 65°C and the chimney provides the required 25 Pa draft.
Is the exhaust fan adjustable?
The fan is factory-set and not user-adjustable, ensuring consistent draft levels throughout the combustion cycle.
How is the fuel loaded into the boiler?
Dry wood pieces up to 730 mm in length are inserted directly through the loading hatch. Fuel should have a moisture content of 12–20% for optimal performance.
What happens if the boiler overheats?
The built-in cooling loop activates to dissipate excess heat. In extreme cases, the safety thermostat will shut down the unit to prevent damage.
Additional parameters
| Category: | Atmos DREVOPLYN wood gasification boilers |
|---|---|
| Warranty: | 2 years |
| Weight: | 497.95 kg |
| Boiler output: | over 40 kW |
| Fuel: | wood |
| Boiler weight: | 433 kg |
| Combustion class: | 4 |
| Energy efficiency class: | A+ |
| Hopper capacity: | 180 dm³ |
| Max. log length: | 730 mm |
| Minimum return water temperature: | 65 °C |
| Output: | 49.9 kW efficiency 87.7% |
| Prescribed fuel: | dry wood with a calorific value of 15 – 18 MJ/kg, diameter 80 – 150 mm and moisture content 12 -20 % |
| Prescribed chimney draught: | 25 Pa |
| Water volume: | 89 L |