ELCU-5000l Plastic underground container - action IVAR.ELCU-5000
Code: 1720557Related products
Product detailed description
Underground plastic tanks like the IVAR ELCU-5000l are commonly used in building water management systems to store and retain potable or rainwater for later use. These tanks are frequently installed in residential, commercial, and industrial settings where water conservation or retention is required. Installers typically work with these tanks in conjunction with pumping stations, filtration systems, or rainwater harvesting setups. The tank is designed for subterranean installation and must be integrated with appropriate inlet and outlet connections to ensure system functionality and compliance with local regulations.
When planning the installation, it is essential to consider the tank’s dimensions, connection requirements, and the surrounding soil conditions. The tank is self-supporting, meaning it does not require additional structural reinforcement when buried. However, proper backfilling and compaction are necessary to prevent ground movement and damage. The tank is suitable for potable water and can also be used for non-water liquids after consultation with the manufacturer.
Technical parameters
| Material | polyethylene monoblock hygienic certificate Note |
|---|---|
| Code | 1720557 |
| Brand | IVAR |
The technical parameters of the IVAR ELCU-5000l are essential for determining its suitability for a specific application. The operating temperature range from -50°C to +60°C allows the tank to be used in a wide range of climates. The hygienic polyethylene monoblock construction ensures the tank is suitable for potable water storage. The self-supporting design eliminates the need for additional support structures during installation.
Installation and connection
Installation of the IVAR ELCU-5000l requires careful planning and adherence to manufacturer guidelines. The tank is designed for underground installation and must be placed in a properly prepared pit. The tank is self-supporting, so no additional structural support is required. However, the surrounding soil must be compacted to prevent shifting or settling. Connections should be made using appropriate fittings and piping that match the tank’s inlet and outlet specifications. It is important to ensure that all connections are watertight and that the tank is properly sealed to prevent contamination or leakage.
Common installation mistakes include improper backfilling, failure to compact the soil adequately, and incorrect connection of inlet and outlet pipes. These errors can lead to tank damage, leakage, or system failure. Installers should also verify that the tank is level and that all access points are accessible for future maintenance.
Compatibility and accessories
The IVAR ELCU-5000l is compatible with a range of pumping and filtration systems, including the IVAR.CB-200 and IVAR.ELCU-10000 models. These systems can be used to pump water from the tank to the building’s distribution network or for further treatment. When installing the tank, it is necessary to order additional components such as inlet and outlet fittings, manhole covers, and sealing gaskets separately. These accessories are not included with the tank and must be specified at the time of order.
Technical background for designers
The IVAR ELCU-5000l operates as a storage and retention tank for potable or rainwater. This material is also hygienic, making it suitable for storing potable water. The tank’s self-supporting design allows it to be installed without additional reinforcement, reducing the need for complex structural support. The tank can be integrated into a larger water management system, including pumping stations, filtration units, and distribution networks. The tank’s performance and service life are influenced by factors such as installation quality, soil conditions, and the type of liquid stored.
Service and operation
Regular inspection and maintenance are essential to ensure the long-term performance of the IVAR ELCU-5000l. Installers should check for signs of damage, leakage, or blockage in the inlet and outlet connections. The tank should also be inspected for signs of wear or degradation, particularly in areas where it is exposed to the surrounding soil. If the tank is used for non-water liquids, it is important to verify that the liquid is compatible with polyethylene and does not cause degradation over time. No specific service intervals are provided in the brief, so maintenance should be performed according to the manufacturer’s technical data sheet.
Frequently asked questions
Can the IVAR ELCU-5000l be used for storing non-potable water?
Yes, the tank is suitable for storing non-potable water and rainwater. However, if it is to be used for non-water liquids, it is necessary to consult with the manufacturer to ensure compatibility.
Is the IVAR ELCU-5000l suitable for use in cold climates?
Yes, the tank is designed to operate in temperatures as low as -50°C, making it suitable for use in cold climates.
Can the IVAR ELCU-5000l be connected to a pumping system?
Yes, the tank is compatible with pumping systems such as the IVAR.CB-200 and IVAR.ELCU-10000 models. Appropriate fittings and piping must be used to ensure a secure connection.
Is the IVAR ELCU-5000l self-supporting?
Yes, the tank is self-supporting and does not require additional structural support during installation. However, proper backfilling and compaction are necessary to prevent damage.
Additional parameters
| Category: | IVAR.ELCU - underground plastic containers |
|---|---|
| Weight: | 2300 kg |
| Material: | plastic (PP, PE, PB, PVC) |
| Material: | polyethylene monoblock hygiene certificate |
| Posledná aktuálizacia ceny: | 28.05.2026 13:41:43 |
Discussion
Be the first who will post an article to this item!