Wholesale e-shop

Electrothermal head - for balancing valve IVAR.CIM 788 - 230V; without current closed IVAR.CIM 311 NC

Code: 311230NC
naparovana cena na magic
–20 %
Vykurovacia technika Elektrotermická hlavica - pre vyvažovací ventil IVAR.CIM 788 - 230V; bez prúdu zatvorené
–20 % €60,48 / pcs €74,39 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

Electrothermal heads are essential components in heating system balancing, especially in commercial and industrial buildings where precise flow control is required. Installers working on central heating systems, particularly those using IVAR.CIM 788 balancing valves, need reliable and accurate control solutions. These systems typically operate under varying load conditions and require consistent performance over time.

This electrothermal head is specifically designed to integrate with the IVAR.CIM 788 balancing valve. It provides a means of remote control and modulation of flow rates, which is critical for maintaining system balance and energy efficiency. The installation environment often includes mechanical rooms, boiler houses, and underfloor heating manifolds, where space and accessibility can be limited. The IP54 rating ensures the unit is protected against dust and water splashes, making it suitable for use in such environments.

Technical parameters

Weight0.186 kg
Code311230NC
BrandIVAR
The technical parameters listed provide essential information for proper selection and integration. The M30 x 1.5 thread size ensures compatibility with the designated valve model. The time constant of 3 minutes indicates how quickly the device responds to changes in control signals, which is important for maintaining system stability during load fluctuations. The IP54 rating confirms its suitability for use in environments with moderate exposure to dust and moisture.

Installation and connection

Installation begins with verifying the correct valve model compatibility. The electrothermal head mounts directly onto the IVAR.CIM 788 balancing valve using the M30 x 1.5 thread. Ensure the connection is fully tightened to prevent leakage or misalignment. The electrical supply must be connected according to the manufacturer’s wiring diagram, ensuring correct polarity and secure terminal connections. Before commissioning, confirm that the system is depressurised and that all electrical connections are properly insulated and secured. Common installation errors include incorrect thread orientation, improper tightening, and incorrect wiring, which can lead to malfunction or damage.

Compatibility and accessories

This electrothermal head is designed exclusively for use with the IVAR.CIM 788 balancing valve and cannot be used with other models without an appropriate adapter. For complete system functionality, ensure that the associated control system is compatible with the signal input requirements of this device. No additional accessories are included; however, an external power supply and control interface may be necessary depending on the system configuration.

Technical background for designers

The electrothermal head operates based on thermal expansion principles, where an internal element reacts to electrical input by expanding or contracting, thereby modulating the valve position. The materials used are selected for durability and resistance to corrosion, ensuring long-term reliability in heating applications. Integration into the system requires careful consideration of the control strategy and actuation response time. The time constant of 3 minutes influences the overall system responsiveness and should be taken into account during design and simulation phases. Environmental factors such as ambient temperature and humidity can affect performance and longevity.

Service and operation

Regular visual inspections are recommended to check for signs of wear, corrosion, or mechanical damage. Ensure that the electrical connections remain secure and free from insulation degradation. While no specific service intervals are provided, any operational anomalies such as sluggish response or inconsistent flow control should be investigated promptly. The device does not require routine calibration or lubrication under normal operating conditions.

Frequently asked questions

Can this electrothermal head be used with other valve models?
It is specifically designed for the IVAR.CIM 788 balancing valve and is not compatible with other models without an appropriate adapter.

What is the significance of the time constant of 3 minutes?
This value indicates the time it takes for the device to respond to a control signal, influencing the speed and accuracy of flow adjustments in the system.

Is it possible to retrofit this head onto existing valves?
Retrofitting is not recommended unless the existing valve is confirmed to be identical to the IVAR.CIM 788 model and the mounting interface matches exactly.

Does the IP54 rating allow outdoor installation?
While it offers protection against dust and water splashes, it is not rated for full weatherproofing and therefore not suitable for continuous outdoor use without additional enclosure.

Additional parameters

Category: Balancing valves
Warranty: 2 years
Weight: 0.186 kg
Product type: balancing / control valve
Posledná aktuálizacia ceny: 13.04.2026 1:02:56