Expansion Tank Cimm ERE CE 300 L
Code: 820300Related products
Product detailed description
Expansion tanks are essential components in closed heating systems, ensuring safe operation by accommodating thermal expansion of the fluid. This model is commonly used in residential and commercial buildings where central heating systems require pressure stabilisation. Installers working on boiler systems, heat pumps or underfloor heating should consider the tank’s dimensions and pressure rating during planning. The tank must be installed in a location accessible for inspection and maintenance, typically near the boiler or circulation pump.
For systems with high water volume, such as those serving large buildings or multiple zones, the tank’s 300 L capacity is critical for maintaining stable pressure levels. The tank’s cylindrical shape allows for efficient space utilisation in mechanical rooms. The operating temperature range ensures compatibility with both low-temperature and conventional heating systems. The red colour provides visual identification for system diagnostics and maintenance.
Technical parameters
| Height | 1220 mm |
|---|---|
| Item number | 820300 |
| Name/capacity | ERE CE 300 L |
| Diameter | 650 mm |
| Connection thread | M 1 inch G |
| Operating pressure | 1.5 bar |
| Maximum pressure | 6.0 bar |
| Operating temperature | -10+100 °C |
| Color | red |
| EAN | 8033003527634 |
| Code | 820300 |
| Brand | Cimm |
Compatibility and accessories
The Cimm ERE CE 300 L expansion tank is compatible with central heating systems using water as the heat transfer medium. It integrates with boilers, heat pumps and solar thermal systems that require expansion management. For optimal performance, it should be used in conjunction with a pressure gauge and safety valve, both of which are not included with the tank. The tank’s red finish is standard and does not affect compatibility with other components. No alternative or related products are available for this model. Installers should ensure that all necessary accessories are ordered separately to complete the system configuration. The tank’s dimensions and connection type make it suitable for a wide range of standard heating installations.Technical background for designers
The tank operates on the principle of a pre-pressurised chamber that absorbs excess fluid volume caused by thermal expansion. The internal diaphragm separates the air chamber from the water chamber, maintaining a balanced pressure within the system. The tank is constructed from durable materials capable of withstanding long-term exposure to water and fluctuating temperatures. The cylindrical shape optimises internal volume and minimises stress points in the tank’s structure. Designers should account for the tank’s dimensions and pressure rating when planning system layouts. The tank’s operating temperature range ensures compatibility with both low-temperature and conventional heating systems. The tank’s service life depends on the quality of the internal diaphragm and the stability of the system pressure. Regular monitoring of the tank’s pressure and condition is recommended to ensure continued performance.Service and operation
Routine checks should include inspecting the tank for signs of wear, leakage or pressure loss. The tank does not require scheduled maintenance, but periodic verification of the system pressure is recommended. If the tank shows signs of reduced effectiveness, such as frequent pressure fluctuations or unusual noise, it should be inspected by a qualified technician. No specific service intervals are provided for this model. During operation, the tank should remain isolated from direct mechanical stress and extreme environmental conditions. The tank’s internal diaphragm is a critical component that should not be exposed to contaminants or excessive pressure. The tank’s design allows for straightforward replacement if necessary, without requiring major system modifications.Frequently asked questions
Can the Cimm ERE CE 300 L be connected to a heat pump system?
Yes, the tank is suitable for use with heat pump systems that require expansion management. The tank’s pressure and temperature ratings are compatible with typical heat pump operating conditions.
Is the tank suitable for outdoor installation?
No, the tank is designed for indoor use only. The operating temperature range excludes prolonged exposure to freezing conditions that could affect the tank’s integrity.
What is the recommended location for installation?
The tank should be installed in a location with sufficient space for access and inspection, typically near the boiler or circulation pump. Avoid locations with high vibration or mechanical stress.
Can the tank be used with glycol-based systems?
No information is provided regarding compatibility with glycol-based systems. Refer to the manufacturer’s technical documentation for confirmation.
Documents for download
Additional parameters
| Category: | Expansion vessels for heating systems |
|---|---|
| Weight: | 108 kg |
| EAN: | 8033003527634 |
| Product type: | expansion / pressure vessel |
| Vessel volume: | over 100 l |
| Výška: | 1220 mm |
| Obj. číslo: | 820300 |
| Názov/objem: | ERE CE 300 L |
| Priemer: | 650 mm |
| Pripojovací závit: | M 1″ G |
| Prevádzkový tlak: | 1,5 bar |
| Maximálny pretlak: | 6,0 bar |
| Prevádzková teplota: | -10+100 °C |
| Farba: | červená |