Safety overflow fuse GST type L-FM - 3/4 "FM; 4m3/h IVAR.GST-L-FM
Code: GS02320200Related products
Product detailed description
The IVAR GST type L-FM gas safety overflow fuse is commonly used in industrial and commercial gas systems to protect against overflows. Installers and technicians working on gas supply lines, particularly in heating and process applications, will find this device essential for maintaining safe and efficient operation. It is often integrated into gas blocks, metering stations, and distribution systems where precise flow regulation is required. The compact design allows for easy installation in tight spaces while ensuring reliable performance under varying conditions.
This safety device operates by restricting the flow of gas when the nominal flow rate is exceeded. It is suitable for both indoor and outdoor installations, provided the ambient conditions remain within the specified limits. The stainless steel construction ensures resistance to corrosion and mechanical wear, making it ideal for environments where gas purity and long-term durability are critical.
Technical parameters
| Material | Stainless steel AISI 316 |
|---|---|
| Weight | 0.126 kg |
| Code | GS02320200 |
| Brand | IVAR |
The technical parameters define the operational range and suitability of the GST type L-FM for specific applications. The 3/4 inch FM thread size ensures compatibility with standard gas piping systems. The maximum flow rate of 4 m3/h is important for sizing the device correctly to match the system demand. The operating temperature range (-20°C to +60°C) and external temperature resistance (+925°C for 60 minutes) indicate the environmental conditions under which the device can function safely.
Installation and connection
Installation requires careful alignment of the internal and external FM threads to ensure a secure and leak-free connection. The device should be mounted in a position that allows for easy access during maintenance and inspection. Before tightening, the installer must verify that the thread surfaces are clean and free of debris. A common mistake is incorrect orientation, which can lead to improper sealing and potential gas leaks. It is also essential to confirm that the system pressure does not exceed the maximum allowable limit of 100 mbar to prevent damage to the device.
Compatibility and accessories
This gas safety overflow fuse is compatible with gas systems using FM threaded connections. When installing, ensure that the entire piping system is designed to accommodate the specified flow rate and pressure range. Additional components such as pressure regulators or filters may be required depending on the system configuration. No specific accessories are required for this model.
Technical background for designers
The GST type L-FM operates by limiting gas flow beyond the rated capacity, preventing overpressure situations that could compromise system integrity. The internal structure is designed to maintain consistent flow characteristics even under fluctuating load conditions. Designers should consider the ambient temperature range and pressure limits when integrating this device into larger gas systems to ensure optimal performance and safety.
Service and operation
Regular visual inspections are recommended to check for signs of wear, corrosion, or blockages. No scheduled service intervals are specified in the technical data. During operation, it is important to monitor the system pressure to ensure it remains within the allowable range. Any sudden drop in flow rate or unusual noise may indicate a blockage or internal damage, requiring further investigation.
Frequently asked questions
Can the GST type L-FM be used in high-temperature environments?
Yes, the device is rated for external temperatures up to +925°C for 60 minutes, making it suitable for high-temperature environments.
Is the GST type L-FM compatible with all gas types?
It is suitable for use with gases that do not react with stainless steel and are within the specified pressure and temperature ranges.
Can the GST type L-FM be installed vertically or horizontally?
Both orientations are acceptable, provided the installation allows for proper sealing and access for maintenance.
What should be checked during commissioning?
During commissioning, verify the thread alignment, seal integrity, and system pressure to ensure the device functions correctly and safely.
Additional parameters
| Category: | IVAR.GST-L-FM/MF - excess flow safety valves |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.126 kg |
| Thread size: | 3/4" |
| Connection type: | female × male thread |
| Material: | stainless steel |
| Material: | stainless steel AISI 316 |
| Posledná aktuálizacia ceny: | 13.04.2026 1:03:32 |
Discussion
Be the first who will post an article to this item!