Siemens Heat Meter 2,5m3/h

Code: WFM503-J000H0
–5 %
Vykurovacia technika Siemens Merač tepla 2,5m3/h
–5 % €155,89 / pcs €191,74 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

The Siemens WFM503-J000H0 heat meter is commonly used in residential and commercial heating systems for accurate measurement of thermal energy consumption. It is typically installed in return pipelines to monitor flow and temperature differentials. The device is suitable for systems with varying load profiles and is often integrated into district heating, individual building heating, and heat cost allocation systems. The compact design allows for installation in tight spaces, and the long battery life minimises the need for frequent maintenance. The mechanical impeller design ensures reliable operation in a range of flow conditions.

This meter is selected for its ability to provide accurate readings over an extended period without the need for external power sources. It is particularly suited for applications where a mechanical flow measurement solution is preferred over ultrasonic alternatives. The installation process requires careful alignment with the pipeline and verification of the flow direction to ensure correct operation. The device is designed for use with water-based heating media and is compatible with standard heating system configurations.

Technical parameters

Weight5 kg
CodeWFM503-J000H0
BrandSIEMENS
The meter operates with a flow range of 0.05 to 5 m³/h and a maximum flow rate of 2.5 m³/h. The 10-year battery life is a key factor in long-term planning and system design. The 36-second temperature measurement cycle ensures sufficient resolution for most heating applications. These parameters are essential for determining the suitability of the meter for a given system, particularly in terms of flow capacity and maintenance intervals.

Installation and connection

The Siemens WFM503-J000H0 is installed in the return pipeline of a heating system using a G 1" connection. The installation requires a minimum straight pipe length upstream and downstream of the meter to ensure accurate flow measurement. The sensor cables are 1.5m in length, allowing for flexibility in positioning the meter relative to the control unit. The installer must verify the flow direction and ensure that the meter is mounted in a position free from mechanical stress. Common installation errors include incorrect orientation and failure to allow sufficient straight pipe lengths, both of which can affect measurement accuracy.

Compatibility and accessories

The meter is compatible with standard heating system components and is designed to integrate with control units that support IrDA communication. Recommended accessories include mounting kits HMXI-K... for secure installation. The WFM503-J000H0 replaces the WFM407 and WFN2 series meters and is not compatible with ultrasonic-based alternatives such as the T230 range. Additional components such as temperature sensors and communication modules may be required depending on the system configuration.

Technical background for designers

The Siemens WFM503-J000H0 uses a mechanical impeller to measure flow, which generates pulses proportional to the volume of water passing through the system. The impeller is housed in a durable casing designed to withstand the operating conditions of heating systems. The temperature sensors are integrated into the meter body and measure the temperature differential between the supply and return lines. The meter calculates the heat energy based on the flow rate and temperature difference. The long battery life is achieved through low-power electronics and efficient signal processing. The design ensures minimal pressure drop and resistance to wear from particulate matter in the water.

Service and operation

The meter requires minimal maintenance due to its long battery life and robust mechanical design. The battery is rated for 10 years, after which it should be replaced. No scheduled service intervals are specified in the brief. The device should be inspected for blockages or damage to the impeller if there is a sudden drop in measurement accuracy. The IrDA output allows for remote data retrieval, reducing the need for physical access to the meter for routine checks.

Frequently asked questions

Can the Siemens WFM503-J000H0 be used in systems with high particulate content in the water?
The mechanical impeller design is suitable for use in water-based heating systems. However, excessive particulate matter may affect the impeller's operation over time.

Is the battery replaceable without removing the meter from the pipeline?
The battery is designed to last 10 years. Replacement typically requires removing the meter from the system.

Can the meter be used in a system with a flow rate higher than 2.5m³/h?
The maximum flow rate is 2.5m³/h. Exceeding this may lead to inaccurate readings or damage to the meter.

Does the meter require a separate power supply for operation?
The meter is powered by an internal battery and does not require an external power supply during normal operation.

Additional parameters

Category: Siemens
Warranty: 2 years
Weight: 5 kg