Square angle valve with ceramic head 1/2"x3/8"
Code: ZK.C10KProduct detailed description
This square angle valve is commonly used in modern bathroom and sanitary installations where angular connections are required between incoming water lines and square-shaped taps or accessories. The angular configuration allows for efficient routing of water supply lines in compact spaces such as under sink areas, behind wall-mounted fixtures, or in utility rooms. The ceramic cartridge ensures leak-free operation with smooth quarter-turn control, making it suitable for both residential and commercial applications. The chrome-plated brass construction provides durability and corrosion resistance, while the angular geometry aligns with contemporary design trends in square-profile fittings.
The valve is typically installed in systems where square taps or accessories are used, such as wall-mounted basins, square-shaped shower systems, or modular bathroom units. It is essential to verify the orientation of the inlet and outlet threads in relation to the existing pipework before installation. This valve is intended for use with cold or warm water supply systems, provided the operating conditions remain within the specified limits of pressure and temperature.
Technical parameters
| Type | Angle valve with square head |
|---|---|
| Connection 1 | G3/8 inch (inlet) |
| Connection 2 | G1/2 inch (outlet) |
| Control element | Ceramic cartridge |
| Material | Brass, chrome |
| Nominal pressure | 10 bar / 1.0 MPa |
| Max. operating temperature | 100°C |
| Packaging | Blister |
| Certification | Declaration of conformity; hygiene certificate |
| Index | ZK.C10K |
| EAN | 5900308742570 |
| Code | ZK.C10K |
| Brand | Hydroland |
Installation and connection
Installation begins with turning off the water supply and draining the system. The valve should be positioned so that the inlet (G3/8 inch) connects to the incoming pipe and the outlet (G1/2 inch) aligns with the fitting or tap. Threaded connections require the use of PTFE tape or sealing compound to ensure a watertight seal. It is important to avoid overtightening, which can damage the ceramic cartridge or deform the brass body. After installation, check for leaks by slowly restoring the water supply and inspecting all joints for drips or seepage.
A common mistake is reversing the inlet and outlet connections, which can lead to poor flow or mechanical stress on the valve. Another potential issue is using the wrong thread type or size, especially when connecting to non-standard fittings. Always verify the direction of rotation when tightening threaded connections to prevent cross-threading. When working with multiple valves in a system, it is good practice to label each one to avoid confusion during reassembly.
Compatibility and accessories
This square angle valve is compatible with square-profile taps and accessories that require angular water supply routing. It is often used in conjunction with square-shaped mixer taps, wall-mounted basins, or integrated sanitary systems. For installations requiring larger flow rates or different connection sizes, alternative models such as the Square angle valve with ceramic head 1/2 inch x 1/2 inch or 1/2 inch x 3/4 inch may be more suitable. Additional items that may need to be ordered include sealing compounds, PTFE tape, or mounting brackets depending on the installation method.
Technical background for designers
The valve operates using a ceramic cartridge mechanism, which allows for precise flow control with minimal wear. The ceramic discs provide a durable sealing surface that resists erosion and maintains tight closure even after many cycles. The brass body offers high strength and thermal conductivity, while the chrome plating prevents oxidation and ensures a long service life. The angular configuration is particularly useful in systems where straight-line routing is impractical due to spatial constraints or architectural design.
When designing a system, it is important to consider the pressure drop across the valve and its impact on overall system performance. The angular design may introduce slight resistance to flow compared to straight-through configurations, so it should be accounted for in hydraulic calculations. The maximum operating temperature of 100°C also limits its use in high-temperature applications such as steam or industrial heating systems. For optimal performance, ensure that the valve is installed in a location with sufficient clearance for maintenance and inspection.
Service and operation
Regular visual inspections should be carried out to check for signs of corrosion, leakage, or mechanical damage. The ceramic cartridge should be tested for responsiveness and tight closure, ensuring that no water escapes when the valve is fully closed. If the valve shows signs of reduced performance or difficulty in operation, it may require disassembly and cleaning. No specific service intervals are provided in the brief, but any maintenance should be performed according to the manufacturer’s guidelines.
During operation, ensure that the water temperature does not exceed 100°C and that the system pressure remains within the specified range. Avoid using excessive force when operating the valve, as this can accelerate wear on the ceramic components. If the valve is part of a larger system, it should be isolated during servicing to prevent unintended water flow or pressure loss elsewhere in the network.
Frequently asked questions
Can this valve be used with hot water systems?
Yes, the valve is suitable for hot water systems with a maximum operating temperature of 100°C.
What is the difference between this model and a standard angle valve?
This model features a square ceramic head, which is specifically designed to match square-profile taps and accessories, whereas standard angle valves typically have round or oval heads.
Can the inlet and outlet be swapped during installation?
No, the inlet is G3/8 inch and the outlet is G1/2 inch, so they must be connected in the correct orientation to avoid misalignment or improper function.
Is a sealing compound required for the threaded connections?
Yes, PTFE tape or a suitable sealing compound should be used to ensure a watertight seal on the threaded connections.
Additional parameters
| Category: | Bathroom equipment |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.18 kg |
| EAN: | 5900308742570 |
| Product type: | valve / accessories |
| Typ: | Rohový ventil, hranatá hlavica |
| Pripojenia: | G1/2'' x G3/8'' |
| Riadiaci prvok: | Keramická kartuša |
| Materiál: | Mosadz, chróm |
| Menovitý tlak: | 10 barov |
| Max. teplota: | 100 °C |
| Balenie: | Blister |
Discussion
Be the first who will post an article to this item!
