Wholesale e-shop

Submersible Sump Pump IBO WQ 1300 Professional

Code: PR_38780
naparovana cena na magic
€277,80 / pcs €341,69 incl. VAT Measure price:
To order

Detailed information

Product detailed description

Submersible sewage pumps are essential in construction and maintenance projects where water removal from sumps, ditches, wells, and septic tanks is required. These installations often occur in civil engineering, infrastructure development, and emergency water extraction scenarios. Installers must consider factors such as flow requirements, head capacity, and the presence of solids in the pumped medium to ensure reliable operation. The IBO WQ 1300 Professional is designed to handle such conditions with its robust construction and thermal overload protection.

When installed in sump pits or dewatering applications, the pump must be fully submerged to function correctly. The system should be integrated with appropriate piping and electrical connections to ensure safe and efficient operation. The pump is suitable for use in temporary or permanent installations, depending on the project requirements. It is commonly used in construction sites, basements, and areas prone to flooding, where rapid water removal is critical.

Technical parameters

EAN5907222763766
Length of supply cable (m)5
Maximum flow rate (l/min)420
Pump voltage (V)230 V
Dimensions H x W (cm)55x27
Pump head (m)12
Weight29.3 kg
CodePR_38780
BrandIBO
The pump's maximum flow rate of 420 l/min and a head of 12 m are key parameters for system sizing. These values determine the pump's ability to move water over a specific distance and elevation. The 230 V supply voltage is standard for single-phase installations, and the 5 m power cable length allows for flexible positioning within the sump. The dimensions (55x27 cm) and weight (29.3 kg) are important for handling and installation logistics.

Installation and connection

Installation begins with ensuring the pump is fully submerged in the sump or pit. The 230 V electrical supply must be connected to a suitable circuit with appropriate protection. The 5 m power cable should be routed to a waterproof junction box or directly to a switchgear panel. The pump is designed for direct immersion and does not require additional priming. It is essential to verify that the pump is installed in a location free from obstructions and that the discharge pipe is properly secured to prevent movement during operation.

Common installation mistakes include insufficient submersion, which can lead to cavitation and overheating, and improper electrical connections that may result in motor failure. The pump must be placed in a stable position to avoid vibration and wear on the seals. The discharge pipe should be sized to handle the maximum flow rate without excessive pressure drop. It is also important to ensure that the pump is not operated in dry conditions, as this can cause damage to the motor and seals.

Compatibility and accessories

The IBO WQ 1300 Professional is compatible with standard 230 V electrical systems and can be integrated into dewatering systems with appropriate piping and fittings. It is recommended to use a non-return valve at the discharge to prevent backflow and a filter at the inlet to reduce the risk of clogging. Additional accessories such as a float switch can be used to automate pump operation based on water level. The pump is suitable for use with standard PVC or metal discharge pipes, and the inlet should be positioned to allow for unrestricted flow.

Technical background for designers

The IBO WQ 1300 Professional operates on a centrifugal pumping principle, where the impeller generates a pressure differential to move water through the system. The pump is constructed with durable materials suitable for handling sewage and contaminated water. The thermal overload protection prevents motor damage from excessive current draw, which can occur during clogging or dry running. The pump's efficiency is influenced by the viscosity of the pumped medium, the presence of solids, and the system's hydraulic resistance. Proper integration into the overall system requires consideration of the pump's flow and head characteristics to ensure optimal performance and longevity.

The pump's service life is affected by the operating conditions, including the frequency of use, the quality of the water being pumped, and the maintenance schedule. Regular inspection of the seals and electrical connections is recommended to prevent leaks and ensure safe operation. The pump is designed for continuous operation in wet conditions and is suitable for use in environments with high humidity and temperature variations.

Service and operation

Regular maintenance includes checking the electrical connections for signs of wear or corrosion and inspecting the pump for blockages or damage. The thermal overload protection should be tested periodically to ensure it functions correctly. The pump should be removed from the water for cleaning if it becomes clogged with debris or solids. No specific service intervals are provided in the brief, but it is recommended to perform routine checks after extended periods of use or in harsh operating conditions.

During operation, the pump should be monitored for unusual noise or vibration, which may indicate mechanical issues. The discharge flow should be checked to ensure it meets the expected performance. If the pump fails to start or operates inefficiently, the cause should be investigated, including checking the power supply, motor condition, and internal components for damage.

Frequently asked questions

Can the IBO WQ 1300 Professional be used in septic tanks?
Yes, the pump is suitable for use in septic tanks and other environments where sewage and contaminated water are present. It is designed to handle solids and is equipped with thermal overload protection to prevent motor damage.

What is the maximum depth at which the pump can be submerged?
The pump is designed for full submersion and can be used in sumps and pits with water depths up to the maximum head capacity of 12 m. It should not be operated in dry conditions to avoid damage.

Is the pump suitable for continuous operation?
Yes, the pump is designed for continuous operation in wet conditions. The thermal overload protection helps prevent motor damage during extended use or in the event of clogging.

What type of electrical supply is required for the pump?
The pump requires a 230 V electrical supply and is compatible with standard single-phase systems. The 5 m power cable allows for flexible positioning within the sump or pit.

Additional parameters

Category: Submersible sump pumps
Weight: 29.3 kg
EAN: 5907222763766
Pump application: sludge / drainage
Max. head: 9 – 20 m
Voltage: 230 V
Dimensions H x W x D (cm): 55x27
Maximum flow rate (l/min): 420
Pump delivery head (m): 12
Pump version - voltage (V): 230 V
Supply cable length (m): 5
EAN: 5907222763766

Discussion

Be the first who will post an article to this item!

Do not fill out this field