Water ball valve TYTAN with lever handle and compression nut 3/4'', F-M
Code: ZKWD-PP-20-NWProduct detailed description
This ball valve is commonly used in residential and commercial buildings for water distribution and heating systems. Installers often encounter it in domestic hot and cold water lines, as well as in central heating circuits. It provides a reliable shut-off function with minimal pressure drop and is suitable for both new installations and system repairs. The quarter-turn operation allows for quick opening and closing, which is essential during maintenance or emergency situations.
The compact design makes it ideal for tight spaces such as under sinks, in boiler rooms or behind wall panels. Its compatibility with standard pipe dimensions ensures straightforward integration into existing infrastructure. The lever handle is ergonomically positioned for ease of access and requires no special tools for operation. The valve is tested for performance and durability before leaving the factory, ensuring consistent quality for professional applications.
Technical parameters
| Connection size | 3/4 inch |
|---|---|
| Thread | G3/4 |
| Connection type | F-M |
| Nominal pressure | 20-30 bar |
| Maximum operating temperature | 120 °C |
| Body material | brass |
| Ball material | chrome-plated brass |
| Sealing | PTFE |
| EAN | 5900308734223 |
| Warranty | 5 years |
| Code | ZKWD-PP-20-NW |
| Brand | Hydroland |
Installation and connection
Before installation, ensure the pipeline is clean and free of debris to prevent damage to the sealing surfaces. Use a wrench to tighten the compression nut securely but avoid over-tightening to prevent thread stripping. The F-M connection allows for direct fitting to male-threaded pipe ends without requiring additional adapters. Check the direction of flow indicated on the valve body to ensure correct orientation. After installation, perform a pressure test to confirm leak-free operation. A common mistake is incorrect alignment of the lever handle, which can cause unnecessary strain on the valve mechanism and lead to premature failure.
When connecting to copper or steel pipes, ensure the threads are fully engaged and apply a small amount of pipe sealant if required by local regulations. For plastic piping systems, use appropriate fittings compatible with the material type. Always verify the integrity of the connection by inspecting for visible signs of stress or deformation after tightening.
Compatibility and accessories
This ball valve is compatible with standard water supply and heating systems using 3/4 inch pipes. It works well with copper, steel and plastic piping when connected via the F-M thread. No special accessories are required for basic installation. However, in complex systems, additional components such as pressure regulators or temperature sensors may need to be integrated depending on the application. Refer to the system design specifications to determine if supplementary valves or fittings are needed for optimal performance.
Technical background for designers
The valve operates by rotating a chrome-plated ball within a brass body. The PTFE sealing creates a tight contact between the ball and the seating surface, preventing leakage. The lever handle provides mechanical advantage, reducing the force required to operate the valve. Integration into the system should consider thermal expansion and contraction to avoid stress on the valve body. The working temperature limit of 120 °C is determined by the properties of the sealing material and the structural integrity of the ball mechanism.
Designers should also account for the flow characteristics of the valve. The fully open position allows unrestricted flow, while the closed position ensures complete isolation. The quarter-turn mechanism is ideal for applications requiring frequent adjustments or emergency shut-off. Longevity is influenced by the quality of the installation, regular maintenance and the chemical composition of the fluid passing through the valve.
Service and operation
Regular inspection of the lever handle and compression nut for signs of wear or loosening is recommended. If the valve becomes difficult to operate, disassemble and clean the internal components to remove debris or deposits. Reapplication of PTFE-based lubricant may improve smoothness of operation. In case of internal leakage, the valve should be replaced rather than repaired, as the sealing surfaces cannot be restored once damaged. The manufacturer provides a five-year warranty against defects in materials and workmanship, provided the valve is used according to the specified parameters.
Frequently asked questions
Can this ball valve be used in a central heating circuit?
Yes, the valve is rated for use in central heating systems with a maximum operating temperature of 120 °C and a pressure range of 20 to 30 bar.
Is the lever handle compatible with automated systems?
No, the lever handle is manually operated and not designed for integration with automated control systems.
Can this valve be installed in a vertical position?
Yes, the valve can be installed in any orientation as long as the lever handle remains accessible and unobstructed.
What is the recommended method for tightening the compression nut?
Use a wrench to tighten the nut until snug, avoiding over-tightening to prevent damage to the threads or sealing surfaces.
Additional parameters
| Category: | With lever handle and compression nut |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.391 kg |
| EAN: | 5900308734223 |
| Product type: | ball valve / shut-off |
| Thread size: | 3/4" |
| Connection type: | female × male thread |
| Material: | brass |
| Rozmer pripojenia: | 3/4" |
| Závit: | G3/4 |
| Typ pripojenia: | F-M |
| Menovitý tlak: | 20-30 bar |
| Max. pracovná teplota: | 120 °C |
| Materiál telesa: | mosadz |
| Guľa: | pochrómovaná mosadz |
| Tesnenie: | PTFE |
| EAN: | 5900308734223 |
| Značka: | Hydroland |
| Záruka: | 2 roky |
Discussion