Assembly distributor IVAR.CS 553 VP, 11-way
Code: 553979Related products
Product detailed description
The IVAR.CS 553 VP 11-way distributor is commonly used in residential and commercial buildings with radiant floor heating systems. It enables precise flow control and heat distribution across multiple zones. Installers working on mixed systems combining floor heating with radiators benefit from the integrated flow measurement and shut-off capabilities. This unit is typically mounted in mechanical rooms or utility areas, where access for maintenance is ensured.
When integrating into a larger heating network, the distributor ensures balanced water flow and facilitates zoning for energy-efficient operation. It is often part of a system that includes circulation pumps, expansion vessels, and thermostatic controls. The inclusion of ball valves and pressure relief features simplifies commissioning and seasonal servicing.
Technical parameters
| Material | Brass CW617N |
|---|---|
| Operating temperature | +90 °C |
| Nominal pressure | PN 10 |
| EAN | 8595145904945 |
| Weight | 23.698 kg |
| Code | 553979 |
| Brand | IVAR |
Installation and connection
Mounting requires securing the unit using the included brackets to a stable surface, such as a wall or dedicated support frame. The inlet and outlet ports are threaded 1" x EK, allowing direct connection to copper or steel pipes. Before tightening connections, verify that all pipe threads are clean and free from burrs. Apply a suitable sealing compound to prevent leaks.
Avoid over-tightening fittings, which can damage the brass components. Ensure the distributor is level during installation to prevent uneven stress on internal components. Connect the individual circuit lines to the collector and distribution manifolds using appropriate pipe sizes and fittings. Verify that all ball valves are in the closed position before pressurising the system.
Compatibility and accessories
This distributor is compatible with standard floor heating manifolds and control systems. For complete system integration, additional components such as circulation pumps, thermostats, and expansion tanks may be required. The set includes two ball valves with handwheels for manual flow control and two connecting unions with automatic air vents and drain valves for system maintenance. All necessary mounting hardware is included.
Technical background for designers
The distributor operates by dividing the incoming hot water supply into multiple circuits and recombining the return flow. The brass CW617N material ensures durability under thermal cycling and maintains structural integrity at high temperatures. The flow meters allow for accurate balancing of each circuit, optimising heat distribution and system efficiency. Designers should account for the pressure drop across the distributor when calculating pump requirements.
Proper insulation of the distributor and connecting pipes minimises heat loss and prevents condensation. The design supports both open and closed-loop systems, depending on the configuration of the heat source and control strategy. System longevity depends on regular flushing and chemical treatment to prevent sediment buildup, as noted in the manufacturer’s guidelines.
Service and operation
Periodic inspection of the distributor includes checking for leaks around the fittings and verifying the operation of the ball valves and air vents. Clean the air vents and drain ports annually to prevent clogging. In mixed systems with radiators, ensure that the entire system is flushed according to the manufacturer’s instructions before commissioning or after major modifications.
Use of the GEL.LONG LIFE 100 treatment is recommended to protect against internal corrosion and scaling. Any operational issues caused by debris in the system are not covered under warranty. Always follow the manufacturer’s maintenance schedule to maintain system performance and safety.
Frequently asked questions
Can the IVAR.CS 553 VP be used in mixed floor and radiator heating systems?
Yes, the distributor is suitable for mixed systems provided the entire system is flushed and treated as specified by the manufacturer before commissioning.
What is the recommended procedure for commissioning the distributor?
Before starting the system, ensure all valves are closed and the distributor is securely mounted. Pressurise the system gradually and check for leaks at all connections.
Does the distributor include all necessary valves for system operation?
The set includes two ball valves with handwheels, two connecting unions with air vents and drain valves, and mounting brackets. Additional valves may be needed depending on the system layout.
Is it possible to replace individual components of the distributor?
Some components such as valves and flow meters can be replaced separately if damaged. Refer to the technical documentation for replacement guidelines.
Additional parameters
| Category: | IVAR CS 553 VP without pump |
|---|---|
| Warranty: | 2 years |
| Weight: | 23.698 kg |
| EAN: | 8595145904945 |
| Product type: | manifold / header |
| Material: | brass |
| Material: | brass CW617N |
| Nominal pressure: | PN 10 |
| Operating temperature: | +90 °C |
| Posledná aktuálizacia ceny: | 13.04.2026 1:05:53 |