Wholesale e-shop

Assembly distributor IVAR.UNIMIX, 4-way

Code: 557672U
naparovana cena na magic
–20 %
UNIMIX - univerzálna zostava - skriňa  P-MAX 3 - 3/4"xEK; 4cestný; DAB.EVOSTA 2 40-70/130; mosadz
–20 % €876 / pcs €1 077,48 incl. VAT Measure price:
In stock

Detailed information

Product detailed description

The IVAR.UNIMIX 4-way assembly distributor is commonly used in residential and commercial buildings where combined floor heating and radiator systems are required. Installers typically encounter these units in multi-zone systems, where precise temperature control and flow distribution are essential. The unit integrates a three-way mixing valve to regulate the return water temperature, ensuring efficient heat distribution while maintaining system stability.

This distributor is designed for professional installation by qualified heating engineers. It connects directly to primary circulation pumps and heating circuits, allowing for modular expansion of the system. The compact design and integrated components make it suitable for mechanical rooms, plant rooms, or concealed installations behind access panels. It is particularly useful when separate controls for floor heating and radiators are needed within a single manifold setup.

Technical parameters

Nominal PressurePN 6
EAN8595145909773
Weight22.777 kg
Code557672U
BrandIVAR

Installation and connection

This unit requires careful alignment with the existing heating circuit piping. Connect the primary supply and return lines using 3/4" threaded connections. Ensure all pipe connections are tightened to the correct torque specifications to prevent leaks. Verify that the direction of flow indicated on the unit matches the system layout. Incorrect orientation can lead to poor performance or damage to internal components. When connecting to a circulation pump, ensure the pump is compatible with the flow rates expected in the system. Check all sealing surfaces and gaskets for wear before final tightening.

Compatibility and accessories

This distributor is intended for use with IVAR floor heating manifolds and compatible circulation pumps. Additional components such as balancing valves, temperature sensors, and control thermostats should be selected according to the system requirements. The unit does not include external controllers or expansion tanks, which must be sourced separately. For larger installations, additional distributors or zoning valves may be required to maintain system balance.

Technical background for designers

The IVAR.UNIMIX operates using a three-way mixing valve to blend heated and return water, maintaining a stable supply temperature to the floor heating circuits. The body is constructed from durable materials suitable for continuous operation under nominal pressure up to PN 6. This ensures long-term reliability in pressurized heating systems. The unit integrates seamlessly into closed-loop hydronic systems, providing a central point for flow distribution and temperature regulation. System efficiency is influenced by proper pump selection and accurate balancing of the secondary circuits. The mixing mechanism helps reduce thermal stress on the boiler and extends the overall lifespan of the system.

Service and operation

Periodic inspection of the unit’s internal components is recommended during routine system maintenance. Check for signs of corrosion, scale build-up, or blockage in the mixing valve. Ensure that all connections remain leak-free and that the unit is operating within the specified pressure range. If a drop in system performance is observed, disassemble the unit for cleaning or replacement of worn parts. No specific service interval is defined in the provided documentation, so follow general industry guidelines for hydronic system maintenance.

Frequently asked questions

Can this unit be used with a variable-speed circulation pump?
Yes, the IVAR.UNIMIX is compatible with variable-speed pumps provided they operate within the pressure and flow limits specified in the technical data sheet.

Is this unit suitable for radiant floor heating with multiple zones?
Yes, the 4-way configuration allows for the connection of multiple floor heating loops, making it suitable for multi-zone radiant floor systems.

Does the unit require a separate temperature controller?
A separate controller is not included but is necessary for automated temperature regulation of the mixing function and individual circuits.

Can the distributor be mounted vertically or horizontally?
Both orientations are acceptable, but the installation must allow for free access to the valve and connections for maintenance purposes.

Additional parameters

Category: IVAR.UNIMIX - underfloor heating/radiator assembly with cabinet
Warranty: 2 years
Weight: 22.777 kg
EAN: 8595145909773
Product type: manifold / header
Nominal pressure: PN 6
Posledná aktuálizacia ceny: 13.04.2026 1:07:33

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.