Wholesale e-shop

Ball cap gas FUTURGAS - 1/2 "MF; lever FIV.80014 P

Code: 80014012
naparovana cena na magic
–20 %
Vykurovacia technika Guľový uzáver plyn FUTURGAS - 1/2"MF; páčka
–20 % €9,36 / pcs €11,51 incl. VAT Measure price:
In stock (14 pcs)

Detailed information

Product detailed description

Gas ball valves are essential components in pressurised gas distribution systems for industrial, commercial and residential applications. They are commonly used in boiler rooms, gas lines and utility systems where secure and leak-proof shut-off is required. The FIV.80014 P is specifically suited for low-pressure gas circuits with PN 5 ratings and must be integrated into systems with compatible pipe dimensions and sealing requirements. Installers should ensure that the valve orientation allows for easy access to the lever during operation and maintenance.

The valve is designed to provide full flow with minimal pressure drop and is suitable for use in both new installations and retrofitting projects. The lever mechanism provides a clear indication of the open or closed position. It is important to align the lever correctly with the flow direction to avoid operational errors and ensure smooth system performance. The extended lever design allows for operation in tight spaces or from a distance.

Technical parameters

MaterialNickel-plated brass CW617N
Operating temperature-20 °C
Nominal pressurePN 5
Weight0.2 kg
Code80014012
BrandIVAR
The operating temperature range of -20°C to +60°C makes this valve suitable for gas systems in cold environments such as unheated utility rooms or outdoor enclosures. The nominal pressure rating of PN 5 ensures compatibility with low-pressure gas circuits. These parameters are critical when selecting the correct valve for a specific application, particularly when considering environmental conditions and system pressure requirements.

Installation and connection

The FIV.80014 P is available in 1/2 inch male-female thread configuration. Before installation, confirm that the pipe threads are clean and undamaged. Apply a suitable thread sealant to the male thread to prevent leaks. The valve can be installed in either horizontal or vertical positions, but the lever should remain accessible for manual operation. A common mistake is improper tightening of the threads, which can lead to leaks or thread damage. Always follow the manufacturer’s torque recommendations for tightening. After installation, perform a visual inspection for alignment and ensure that the lever moves freely without binding.

Compatibility and accessories

This valve is compatible with standard gas piping systems using 1/2 inch threaded connections. For complete system functionality, it should be used with appropriate fittings, such as elbows, tees and adapters, also rated for PN 5. Additional components may include pressure regulators, filters or safety shut-off devices depending on the system design. Ensure that all components are made from materials compatible with gas media and operating conditions.

Technical background for designers

The ball valve operates via a rotating ball with a central bore that aligns or blocks the flow path. The nickel-plated brass CW617N body provides resistance to corrosion and wear, making it suitable for long-term use in gas systems. The extended lever design allows for mechanical advantage, reducing the effort required for opening and closing. The valve is intended for integration into low-pressure gas circuits and requires careful consideration of thermal expansion and contraction in the piping system to maintain a reliable seal over time.

Service and operation

Regular visual inspections are recommended to check for signs of wear, corrosion or leakage around the threads. No scheduled maintenance is required beyond these checks. If the lever becomes stiff or difficult to operate, disassemble the valve and inspect the internal components for debris or damage. Avoid using excessive force when operating the lever, as this can cause premature wear or failure. Always close the valve before disconnecting or replacing any components in the system.

Frequently asked questions

Can the FIV.80014 P be used in water systems?
No, the valve is specifically rated for gas systems with operating temperatures up to +60°C. Water applications require a different temperature and pressure rating.

Is the lever reversible for left-hand or right-hand operation?
The lever is fixed in position and cannot be reversed. Ensure that the valve is installed in a location where the lever can be operated comfortably.

Can this valve be used in a vertical pipeline?
Yes, the valve can be installed in vertical pipelines provided that the lever remains accessible and the flow direction is aligned with the valve's design.

What sealant should be used for the threaded connection?
A thread sealant compatible with gas media and nickel-plated brass should be applied to the male thread before tightening to ensure a leak-free connection.

Additional parameters

Category: Female - male, lever handles
Warranty: 2 years
Weight: 0.2 kg
Product type: plug / cap
Thread size: 1/2"
Connection type: female × male thread
Material: brass
Material: nickel-plated brass CW617N
Nominal pressure: PN 5
Operating temperature: -20 °C
Posledná aktuálizacia ceny: 13.04.2026 1:04:37

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.