Dynamic thermostatic valve - three-axis, 1/2" P
Code: 500511Related products
Product detailed description
This dynamic thermostatic valve is commonly used in residential and commercial heating systems to provide automatic flow control and thermal regulation. It is typically installed on radiators or in district heating circuits to maintain consistent room temperatures while optimising energy efficiency. The three-axis design allows for precise adjustment and ensures stable operation under varying load conditions. Installers will find it particularly useful in systems with uneven heat distribution or where manual balancing would be impractical.
The valve is designed for use with steel piping systems and is intended for installation by qualified heating engineers. It is commonly used in panel heating, underfloor heating and radiator circuits. The nickel-plated brass construction ensures durability and resistance to corrosion in wet environments. The pre-set Kv value helps simplify system design and reduces the need for on-site recalibration.
Technical parameters
| Material | Nickel-plated brass CW617N |
|---|---|
| Operating temperature | 120 °C |
| Nominal pressure | PN 10 |
| Weight | 0.1 kg |
| Code | 500511 |
| Brand | IVAR |
The operating temperature limit of 120°C makes this valve suitable for use in high-temperature heating systems. The PN 10 pressure rating indicates it can handle moderate system pressures typical of central heating applications. The CW617N brass alloy provides good mechanical strength and corrosion resistance, making it ideal for long-term use in wet environments. These parameters are essential for proper system sizing and ensure compatibility with standard heating system components.
Installation and connection
Installation should be carried out by a qualified technician following standard heating system procedures. The valve connects to steel pipes using a 1/2 inch pipe thread and requires a head with M30 x 1.5 thread for control. Ensure the pipe is clean and free of debris before fitting the valve. A torque wrench should be used to tighten the connection to the recommended specification to prevent leaks. Common mistakes include incorrect orientation of the valve body and failure to align the axis correctly, which can lead to poor flow control or system imbalance.
Compatibility and accessories
This valve is compatible with standard steel pipe systems and requires a compatible control head for full functionality. The M30 x 1.5 thread allows for use with a range of thermostatic heads available on the market. For complete system integration, ensure the control head is calibrated to match the pre-set Kv value. Additional components such as pipe unions and sealing rings may be required depending on the installation method and pipe type.
Technical background for designers
The three-axis design allows the valve to adjust flow dynamically in response to temperature changes. The CW617N material is chosen for its resistance to dezincification and its ability to maintain structural integrity under thermal cycling. The pre-set Kv value simplifies system design by reducing the need for field adjustments, making it suitable for use in pre-balanced heating circuits.
Service and operation
Regular inspection of the valve is recommended to ensure continued performance. Check for signs of wear, leakage or blockage in the internal flow path. The sealing surfaces should be cleaned periodically to maintain tightness. No scheduled service intervals are specified, but any visible damage or abnormal operation should be addressed immediately by a qualified technician. Proper installation and use within the stated operating limits will maximise the valve’s service life.
Frequently asked questions
Can this valve be used with copper or plastic piping?
No, the valve is designed specifically for steel pipe systems. Using it with other pipe materials may require additional fittings and could affect flow characteristics.
Is it possible to adjust the pre-set Kv value after installation?
No, the Kv value is factory preset and cannot be adjusted in the field. If a different flow rate is required, a valve with a different pre-set value must be selected during ordering.
What is the maximum allowable pressure drop across the valve?
The valve is rated for PN 10, meaning it is suitable for systems with a maximum working pressure of 10 bar. Exceeding this limit may compromise the integrity of the valve or cause leakage.
Can this valve be used in chilled water systems?
Not according to the manufacturer's specifications. The valve is designed for heating applications with a maximum operating temperature of 120°C and is not suitable for use in cooling systems.
Additional parameters
| Category: | For ladders |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.1 kg |
| Product type: | thermostatic valve |
| Thread size: | 1/2" |
| Material: | brass |
| Material: | nickel-plated brass CW617N |
| Nominal pressure: | PN 10 |
| Operating temperature: | 120 °C |
| Posledná aktuálizacia ceny: | 13.04.2026 1:06:54 |
Discussion
Be the first who will post an article to this item!