Expansion vessel for Domestic Hot Water IBAIONDO 8L
Code: NP.CWU.08.IBProduct detailed description
Expansion vessels are essential components in closed hot water systems, particularly in residential and commercial buildings where water heating systems generate pressure changes. This vessel is commonly installed on the cold or hot side of a domestic hot water (DHW) storage tank to manage pressure variations caused by thermal expansion. The unit is designed for use in systems with fixed pressure limits and requires careful integration to ensure system stability and safety.
Typical applications include DHW systems in single-family homes, apartment blocks, and small commercial buildings. The vessel is installed in a location accessible for inspection and maintenance, with sufficient space for the pressure gauge and valve. It is not intended for use in open systems or high-pressure industrial applications. The vessel is compatible with systems operating within the specified temperature and pressure ranges and should be selected based on the system's expansion requirements.
Technical parameters
| Type | Expansion vessel for domestic hot water |
|---|---|
| Volume | 8 l |
| Max. working pressure | 10 bar |
| Pre-charge pressure | 3 bar |
| Operating temperature | -10°C to +100°C |
| Membrane | Fixed EPDM |
| Material | Steel with powder coating, wall thickness 1 mm |
| Colour | White |
| Connection | 3/4 inch |
| Net weight | 1.920 kg |
| Warranty | 2 years |
| EAN | 5900308748732 |
| Code | NP.CWU.08.IB |
| Brand | Hydroland |
Can this expansion vessel be connected to an open DHW system?
No, the vessel is designed for use in closed systems only. Connecting it to an open system would result in improper pressure management and potential damage to the vessel.
Is the initial pressure adjustable after installation?
Yes, the initial pressure can be adjusted using a pressure gauge and pump. The recommended pressure is 3 bar, and it should be checked periodically to ensure system stability.
Can the vessel be used in systems with higher pressure than 10 bar?
No, the maximum working pressure is 10 bar. Exceeding this limit may cause structural failure and should be avoided by using a pressure relief valve as part of the system design.
What is the recommended installation orientation?
The vessel should be mounted vertically to ensure proper membrane function and prevent air pockets. Horizontal installation may lead to uneven pressure distribution and reduced efficiency.
Additional parameters
| Category: | Drinking water expansion vessels |
|---|---|
| Warranty: | 2 years |
| Weight: | 1.92 kg |
| EAN: | 5900308748732 |
| Product type: | expansion / pressure vessel |
| Thread size: | 3/4" |
| Connection type: | male thread |
| Material: | steel / cast iron |
| Vessel volume: | up to 8 l |
| Typ: | Expanzná nádoba - teplá úžitková voda |
| Objem: | 8 l |
| Max. pracovný tlak: | 10 bar |
| Predbežný tlak: | 3 bar |
| Pracovná teplota: | -10°C až +100°C |
| Membrána: | Pevná EPDM |
| Materiál: | Oceľ, práškový náter, 1 mm |
| Farba: | Biela |
| Pripojenie: | 3/4'' |
| Hmotnosť: | 1,92 kg |
| Záruka: | 2 roky |