Wholesale e-shop

JET 132 M Self-priming pump - action – SALE DAB.JET

Code: 102660100
Action naparovana cena na magic
–10 %
Vykurovacia technika JET 132 M Samonasávacie čerpadlo - akcia
–10 % €307,80 / pcs €378,59 incl. VAT Measure price:
In stock at supplier

Detailed information

Product detailed description

The IVAR JET 132 M self-priming pump is commonly used in residential and commercial water supply systems, irrigation, and pump stations where reliable transfer of clean water is required. It is suitable for installations where the pump must start without a full suction line, such as in systems with dry starts or where the water source is below the pump level. The pump is designed for use in environments where the water temperature ranges from 0°C to 35°C for domestic applications and up to 40°C for other uses. It is frequently installed in pump houses, basements, and utility rooms, and integrated into systems requiring moderate to high head and flow.

This model is ideal for professionals who require a durable and efficient solution for transferring clean, non-corrosive, non-abrasive, and non-viscous water. The pump is built to handle a wide range of flow and pressure demands, making it suitable for both single and multi-stage applications in plumbing and irrigation systems.

Technical parameters

Code102660100
BrandIVAR

The operating range of the IVAR JET 132 M is from 0.4 to 10.5 m³/h with a maximum head of 62 m. These parameters are essential for determining the suitability of the pump for a specific installation. The maximum working pressure is 6 bar (600 kPa), which must be considered when selecting the pump for a system. The temperature range of the pumped liquid also influences the choice of pump material and motor protection.

Installation and connection

Installation of the IVAR JET 132 M requires careful preparation of the suction and discharge lines. The pump must be connected to a clean water supply without suspended solids or abrasive particles. The suction line should be sized appropriately to avoid excessive friction losses and ensure efficient self-priming. The discharge line must be connected with the correct fittings and valves to control flow and pressure. The pump is equipped with a built-in ejector, which must be positioned correctly to ensure proper priming. The motor must be connected according to the manufacturer's specifications, with appropriate overload protection for three-phase versions. Common installation mistakes include incorrect pipe sizing, failure to secure the pump base, and improper alignment of the motor and pump shaft.

Compatibility and accessories

The IVAR JET 132 M is compatible with standard plumbing and irrigation systems that use clean water. It can be integrated with pressure tanks, control panels, and flow meters to enhance system functionality. Additional accessories such as check valves, strainers, and pressure gauges are recommended to ensure stable operation and prevent backflow. The pump is not compatible with aggressive or viscous fluids and should not be used with water containing suspended solids or chemicals. Related products include other models in the JET series, such as JETINOX and JETCOM, which offer different material options for specific applications.

Technical background for designers

The IVAR JET 132 M operates using a self-priming mechanism with a built-in ejector and a single multifunction impeller. The cast iron body provides durability and resistance to corrosion in clean water environments. The enclosed asynchronous motor is cooled by external ventilation, ensuring stable operation in enclosed spaces. The motor is protected by an internal thermal cut-out for single-phase versions, while three-phase models require external overload protection. The pump is designed for integration into systems with variable flow and pressure demands. The service life and efficiency of the pump are influenced by the quality of the water being pumped, the frequency of dry running, and the maintenance of the motor and seals.

Service and operation

Regular inspection of the pump's seals, impeller, and motor is recommended to ensure long-term performance. The pump should be checked for signs of wear, leakage, or unusual noise. The motor and electrical connections should be kept clean and dry to prevent damage. The pump should not be operated under dry conditions for extended periods, as this can cause overheating and damage to the internal components. No specific service intervals are provided in the technical data, but routine maintenance is advised based on the operating conditions and usage frequency.

Frequently asked questions

Can the IVAR JET 132 M be used with water at 40°C?
Yes, the pump can be used with water at up to 40°C for non-domestic applications, provided the water is clean and non-aggressive.

Is the pump suitable for use in a system with a pressure tank?
Yes, the pump can be integrated with a pressure tank to maintain stable pressure and reduce the frequency of pump cycling.

Can the pump be installed in a vertical position?
Yes, the pump can be installed in a vertical orientation, but the suction and discharge connections must be aligned correctly to ensure proper flow and priming.

Does the pump require a check valve on the discharge line?
Yes, a check valve is recommended on the discharge line to prevent backflow and maintain system pressure when the pump is not operating.