Flow meters are essential components in hydronic heating systems, particularly in multi-circuit manifolds used in residential and commercial buildings. These devices enable precise control of flow rates in individual circuits, ensuring balanced distribution and efficient system operation. Installers working with IVAR manifolds often encounter the need to integrate flow measurement and regulation into the system design, especially when combining different heating methods such as underfloor heating and radiators. Proper installation and calibration of flow meters help maintain system performance and prevent issues such as thermal imbalance or excessive pressure drops.
Technical parameters
| Operating temperature | +90 °C |
|---|---|
| Nominal pressure | PN 10 |
| EAN | 8595145919895 |
| Weight | 0.105 kg |
| Code | KIT50620454 |
| Brand | IVAR |
Compatibility and accessories
This flow meter is specifically designed for use with IVAR.CS 553, IVAR.CI 553 and IVAR.CI 557 manifolds. It is not compatible with other manifold types or systems outside the IVAR range. When ordering, ensure that the manifold model is compatible with the flow meter. Additional accessories such as sealing materials and mounting brackets may be required for a complete installation. Refer to the manufacturer's documentation for a list of recommended components.Technical background for designers
The flow meter operates by measuring the instantaneous flow rate of the heating medium through the circuit. It is constructed from PPA and ABC plastics, which offer resistance to thermal and chemical stress in heating systems. The design allows for integration into manifold systems without disrupting the flow dynamics. The accuracy of the meter is influenced by the cleanliness of the system and the stability of the flow conditions. Regular maintenance and system flushing are essential to preserve the meter's performance and extend its service life.Service and operation
To maintain the flow meter's functionality, it is recommended to flush the entire heating system before commissioning, especially when combining different heating methods. This helps remove debris and contaminants that could affect the meter's readings. The use of a system treatment such as GEL.LONG LIFE 100 is advised to prevent corrosion and scaling. While no specific service intervals are provided, periodic inspections for leaks, blockages or signs of wear are recommended to ensure continued operation.Frequently asked questions
Can this flow meter be used with other IVAR manifold models besides those listed?
No, it is specifically designed for use with IVAR.CS 553, IVAR.CI 553 and IVAR.CI 557 manifolds. Compatibility with other models is not guaranteed.
What should be done if the flow meter shows inconsistent readings after installation?
Check the system for blockages or debris and ensure the flow direction is correct. If the issue persists, consult the manufacturer's technical documentation for troubleshooting steps.
Is it necessary to use the recommended system treatment during installation?
Yes, using a treatment such as GEL.LONG LIFE 100 is advised to prevent corrosion and scaling, which can affect the meter's performance and longevity.
Can this flow meter be used in systems with higher operating temperatures?
No, the maximum operating temperature is specified as +90 °C. Use in systems with higher temperatures may cause damage or inaccurate readings.
Additional parameters
| Category: | Accessories for system boards |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.105 kg |
| EAN: | 8595145919895 |
| Product type: | manifold / header |
| Thread size: | 5/4" |
| Connection type: | compression fitting |
| Nominal pressure: | PN 10 |
| Operating temperature: | +90 °C |