Heating safety valves are essential components in central heating systems to prevent excessive pressure build-up that could damage the system or pose safety risks. This model is suitable for residential and commercial buildings where pressure regulation is critical during normal operation and thermal expansion events. Installers typically work with closed-loop systems where the valve is positioned near the boiler or expansion vessel to manage pressure effectively.

The IVAR PV 1234 is commonly used in systems with circulating pumps and heat exchangers. It is installed in the primary circuit, downstream of the boiler, to release excess pressure when the set threshold is exceeded. The valve must be accessible for inspection and maintenance and should be mounted in a way that allows for direct drainage of released media.

Technical parameters

MaterialBrass CW617N
Operating temperature0 °C
Nominal pressurePN 16
CodeI00206060
BrandIVAR
The operating temperature range is specified from 0 °C to +110 °C, allowing use in both cold and heated conditions. The nominal pressure rating of PN 16 indicates the valve is suitable for systems operating under medium-pressure conditions. These parameters are essential for correct sizing and selection based on the system's pressure and temperature profile.

Installation and connection

The valve features a 1/2 inch male metric thread (MF) for direct connection to the system piping. Ensure the pipe is clean and free of debris before installation. Use a wrench to tighten the connection securely but avoid over-tightening which can damage the threads or sealing surfaces. Verify the direction of flow indicated on the body and align accordingly. A common mistake is incorrect orientation, which can affect the valve’s response time and sealing performance. After installation, perform a visual inspection and pressure test at a level below the opening pressure to confirm proper seating and sealing.

Compatibility and accessories

This valve is compatible with standard central heating systems using water as the heat transfer medium. It is typically used alongside expansion vessels, pressure gauges, and boiler controls. No additional accessories are required for basic installation, though a drip tray may be recommended if the installation location is sensitive to water exposure.

Technical background for designers

The valve operates by opening when the system pressure exceeds the set overpressure range, which can be selected between 1.8 bar and 6 bar. The CW617N brass body provides good corrosion resistance and mechanical strength, making it suitable for long-term use in wet environments. The design allows for rapid pressure relief without requiring manual intervention. Proper integration into the system requires consideration of the boiler's maximum operating pressure and thermal expansion characteristics. The valve's response time and flow capacity should match the system's requirements to ensure effective pressure management. Frequent pressure spikes or incorrect sizing can reduce the valve’s service life and efficiency.

Service and operation

Routine maintenance includes visual inspections for signs of corrosion, leakage, or blockage. The valve does not require scheduled servicing unless abnormal operation is observed. In such cases, the valve should be removed and inspected for internal deposits or wear. During operation, the valve should remain fully closed until the set pressure is reached. Any unintended opening or slow closure may indicate a need for replacement or adjustment. Always refer to the manufacturer’s guidelines for specific servicing procedures.

Frequently asked questions

Can the IVAR PV 1234 be used in a system with a pressure higher than 6 bar?
No, the valve is designed to open at a maximum overpressure of 6 bar. Exceeding this pressure without an appropriate safety mechanism can cause system failure.

Is the valve suitable for use with glycol-based heat transfer fluids?
According to the manufacturer's technical data sheet, compatibility with glycol mixtures should be confirmed separately. This valve is primarily intended for use with water-based systems.

How is the overpressure setting adjusted?
The valve is supplied with a fixed overpressure setting within the 1.8 to 6 bar range. Adjustment is not possible without specialist tools and is not recommended for standard installations.

Can the valve be installed vertically or horizontally?
Both orientations are acceptable provided the flow direction marked on the body is respected and the valve remains accessible for inspection and maintenance.

Additional parameters

Category: IVAR.PV 1234 - for heating
Weight: 0.2 kg
Product type: safety valve
Thread size: 1/2"
Connection type: female × male thread
Material: brass
Material: brass CW617N
Nominal pressure: PN 16
Operating temperature: 0 °C
Posledná aktuálizacia ceny: 13.04.2026 1:05:33

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.