Wholesale e-shop

Safety valve IVAR.PV 527, 1" F x 5/4" F; 6bar

Code: 527660
naparovana cena na magic
–20 %
Vykurovacia technika Poistný ventil pre kúrenie - 1"Fx5/4"F; 6bar
–20 % €94,40 / pcs €116,11 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

Heating systems in residential and commercial buildings require reliable pressure protection to ensure safe operation. Safety valves are essential components in such systems, especially in boilers, heat exchangers and circulation circuits. Installers and service technicians must select the correct valve type and pressure setting to match the system requirements. The IVAR.PV 527 is suitable for installations where pressure relief is needed at a defined threshold to prevent overpressure conditions.

Proper integration of the safety valve into the system ensures that it can respond quickly to pressure fluctuations. The valve must be installed in a location that allows for easy access during maintenance and inspection. It is important to verify the system pressure and flow characteristics to determine the appropriate valve size and setting. The IVAR.PV 527 is designed to handle typical heating system pressures and temperatures, making it a suitable choice for a wide range of applications.

Technical parameters

MaterialBrass CB753S
Operating temperature+5 °C
Nominal pressurePN 10
EAN8016615013276
Weight1.312 kg
Code527660
BrandIVAR
The technical parameters of the IVAR.PV 527 are essential for correct sizing and selection. The nominal pressure rating of PN 10 indicates the maximum allowable working pressure under standard conditions. The operating temperature range from +5 °C to +110 °C allows for use in both cold and hot water systems. The material, brass CB753S, ensures durability and resistance to corrosion in typical heating environments.

Installation and connection

Installation of the IVAR.PV 527 requires attention to the connection sizes and thread types. The valve features a 1 inch female thread on one end and a 5/4 inch female thread on the other, allowing for secure and leak-free connections. It is important to ensure that the system piping is compatible with these thread sizes and that the valve is installed in the correct orientation. Common installation mistakes include incorrect thread engagement or failure to use appropriate sealing materials. Installers should also verify the system pressure and flow conditions to confirm that the valve is suitable for the intended application.

Compatibility and accessories

The IVAR.PV 527 is compatible with standard heating system components such as boilers, heat exchangers and circulation pumps. It is designed to work with systems that operate within the specified pressure and temperature ranges. When installing the valve, it may be necessary to use additional components such as pressure gauges or shut-off valves to ensure proper system control. No specific accessories are required for this model, but installers should always refer to the manufacturer's guidelines for recommended system configurations.

Technical background for designers

The IVAR.PV 527 operates as a direct-acting safety valve, which opens in response to excess pressure within the system. The brass CB753S material provides good mechanical strength and resistance to thermal expansion, making it suitable for long-term use in heating applications. The valve is designed to integrate seamlessly into the system, with the connection sizes and pressure rating selected to match typical system requirements. The service life and efficiency of the valve depend on factors such as the operating conditions, system maintenance and correct installation.

Service and operation

Regular inspection of the IVAR.PV 527 is important to ensure continued reliable operation. Installers should check for signs of wear, corrosion or leakage and verify that the valve opens and closes correctly. No specific service intervals are provided for this model, but it is recommended to inspect the valve during routine system maintenance. If any issues are identified, the valve should be replaced or repaired according to the manufacturer's guidelines.

Frequently asked questions

Can the IVAR.PV 527 be used in hot water heating systems?
Yes, the valve is suitable for hot water systems with operating temperatures up to +110 °C.

What is the maximum pressure the IVAR.PV 527 can handle?
The valve has a nominal pressure rating of PN 10 and is designed for a pressure range up to 6 bar.

Is the IVAR.PV 527 compatible with 1 inch and 5/4 inch piping?
Yes, the valve features 1 inch and 5/4 inch female threads for secure connections.

What material is used for the construction of the IVAR.PV 527?
The valve is constructed from brass CB753S, which provides good durability and resistance to corrosion.

Additional parameters

Category: IVAR.PV 527 - for heating
Warranty: 2 years
Weight: 1.312 kg
EAN: 8016615013276
Product type: safety valve
Thread size: 1"
Connection type: female thread
Material: brass
Material: brass CB753S
Nominal pressure: PN 10
Operating temperature: +5 °C
Posledná aktuálizacia ceny: 19.06.2026 8:37:23

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.