Water ball valve TYTAN with union, compression nut and lever handle 1", F-M
Code: ZKWSDR-PP-25Product detailed description
This quarter-turn ball valve is designed for installation in residential, industrial and commercial water supply and central heating circuits. Installers commonly use it in domestic plumbing systems, heating circuits and water distribution lines to provide reliable flow control. The compact design allows for installation in tight spaces such as under sinks, behind panels or within mechanical rooms. As a fixed-flow component, it requires no regular adjustment and is selected based on pipe size, operating pressure and system temperature.
The device integrates into both low-pressure and medium-pressure systems, serving as a shut-off or directional control point. Due to its robust construction and sealed actuation mechanism, it is suitable for environments with fluctuating temperatures and pressures. Technicians often pair it with complementary fittings to ensure leak-free connections and long-term performance.
Technical parameters
| Connection size | 1" |
|---|---|
| Thread | G1 |
| Connection type | F-M with union |
| Nominal pressure | 30 bar |
| Maximum working temperature | 120 °C |
| Body material | Brass |
| Ball material | Chrome-plated brass |
| Sealing | PTFE |
| Net weight | 0.606 kg |
| EAN | 5900308747025 |
| Warranty | 5 years |
| Code | ZKWSDR-PP-25 |
| Brand | Hydroland |
The nominal pressure rating of 30 bar ensures suitability for standard water supply and heating systems. With a maximum operating temperature of 120°C, it functions effectively in both hot and cold water applications. The 1-inch connection size is compatible with standard plumbing configurations, while the union allows for modular assembly and replacement without cutting the pipe.
Installation and connection
Begin by ensuring the pipeline is empty and depressurised. Clean the internal threads of the pipe and apply a suitable thread sealant if required. Insert the valve into the system using the female-to-male G1 thread with union. Tighten the union nut gradually using a wrench, checking for even tightening to avoid misalignment. After installation, verify the seating of the ball against the sealing surface by turning the lever through a full quarter turn. Confirm there is no leakage by testing the system with water under pressure. Common installation errors include over-tightening the union, which can distort the body, or using incorrect sealing compounds that degrade over time.
Compatibility and accessories
This valve is compatible with standard water and heating systems that use 1-inch G1 threaded piping. To complete the installation, ensure unions, sealing rings or pipe cutters are available. No additional parts are required for basic operation, though expansion joints may be necessary in high-vibration environments. Refer to the manufacturer’s technical documentation for specific combinations with other components.
Technical background for designers
The ball valve operates via a pivoting spherical disc that aligns or blocks the flow path when turned. The chrome-plated brass ball provides resistance to corrosion and wear, while the PTFE sealing ring ensures a tight closure. Brass construction offers strength and thermal stability, making it suitable for mixed-use systems. The union allows for disassembly without removing the entire valve from the pipeline. Designers should consider the pressure and temperature ratings when integrating into larger systems, ensuring that supporting components match the valve’s operational limits.
Service and operation
Due to its sealed actuation and robust design, the valve requires minimal maintenance. Periodically inspect for signs of leakage around the union and lever mechanism. If the lever becomes stiff during operation, disassemble the valve and clean the internal components. Lubrication is generally unnecessary unless specified by the manufacturer. There are no defined service intervals beyond routine visual checks. In case of failure, the modular design allows for quick replacement of individual parts rather than the whole unit.
Frequently asked questions
Can the TYTAN valve be used in steam systems?
No, it is not designed for steam applications as the maximum operating temperature is limited to 120°C.
Is the union removable without cutting the pipe?
Yes, the union allows for removal and replacement without disconnecting the entire pipeline.
What thread type is used for the connection?
The valve features a G1 female-to-male connection with a union, suitable for standard plumbing systems.
Can the lever handle be adjusted for left-hand or right-hand operation?
No, the lever is fixed in orientation and cannot be repositioned after installation.
Additional parameters
| Category: | With union, compression nut and lever handle |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.606 kg |
| EAN: | 5900308747025 |
| Product type: | ball valve / shut-off |
| Thread size: | 1" |
| Connection type: | female × male thread |
| Material: | brass |
| Rozmer pripojenia: | 1" |
| Závit: | G1 |
| Typ pripojenia: | F-M so spojkou |
| Menovitý tlak: | 30 bar |
| Max. pracovná teplota: | 120 °C |
| Materiál telesa: | mosadz |
| Guľa: | pochrómovaná mosadz |
| Tesnenie: | PTFE |
| Hmotnosť netto: | 0.606 kg |
| EAN: | 5900308747025 |
| Značka: | Hydroland |
| Záruka: | 2 roky |