Water ball valve TYTAN with union, compression nut and lever handle 3/4", F-M
Code: ZKWSDR-PP-20Product detailed description
This full-bore ball valve is commonly used in residential and commercial heating systems, as well as domestic water supply lines. It allows for precise and reliable shut-off without restricting fluid flow, making it ideal for applications where maintaining maximum throughput is critical. Installers working on existing piping layouts benefit from the adjustable compression nut, which compensates for minor misalignments during installation.
The TYTAN valve is particularly suitable for systems requiring frequent access for maintenance or seasonal adjustments. Its compact design and durable materials make it a preferred choice in both new construction and retrofit projects. The quarter-turn lever ensures quick operation, while the chrome-plated ball and PTFE sealing ensure long-term reliability in environments with fluctuating temperatures and pressures.
Technical parameters
| Type | Full-bore ball valve with union |
|---|---|
| Connection | G3/4'' (F-M) with union/compression nut |
| Body material | Brass, electro-nickel plated |
| Ball | Chrome-plated brass, PTFE sealing, full bore |
| Handle | Steel lever with PVC coating, 1/4 turn operation |
| Nominal pressure | 30 bar / 3.0 MPa |
| Max. operating temperature | 120°C |
| Medium | Hot and cold water, heating systems |
| Net weight | 0.368 kg |
| Warranty | 5 years |
| EAN | 5900308747018 |
| Code | ZKWSDR-PP-20 |
| Brand | Hydroland |
Installation and connection
The valve connects via a G3/4'' F-M thread, allowing it to be integrated directly into standard pipe systems. To install, first clean the threads and apply a suitable sealing compound or PTFE tape. Ensure that the union nut is properly tightened to avoid leaks. The adjustable compression nut allows for fine-tuning of the alignment between connecting pipes, reducing stress on the valve body.
A common mistake during installation is over-tightening the union nut, which can damage the sealing surfaces. Always follow the manufacturer’s tightening torque recommendations. Another potential issue is incorrect orientation of the lever handle, which should be positioned for easy access and smooth operation. After installation, perform a leak test under pressure to confirm the integrity of the connections.
Compatibility and accessories
The TYTAN ball valve is compatible with standard copper, steel, and plastic piping systems using G3/4'' threaded connections. For optimal performance, ensure that all connected components are rated for the same operating conditions—specifically, a maximum temperature of 120°C and a pressure rating of at least 30 bar.
No additional accessories are required for basic installation, although sealing compounds or PTFE tape may be recommended depending on local standards. When integrating the valve into complex systems, consider using compatible isolation valves or pressure regulators to maintain system stability and safety.
Technical background for designers
The TYTAN operates via a quarter-turn mechanism that opens or closes the flow path by rotating the lever. The chrome-plated brass ball provides resistance to corrosion and wear, ensuring consistent performance even in high-temperature environments. The PTFE sealing material offers low friction and maintains a tight seal over time, reducing the need for frequent maintenance.
The valve’s brass body, electro-nickel plated for corrosion resistance, is suitable for use in both indoor and outdoor applications. The stainless steel lever handle with PVC coating enhances durability and ergonomics, allowing for effortless operation. When designing systems, account for the valve’s compact footprint and ensure adequate clearance around the union nut for adjustment and maintenance.
Service and operation
Regular visual inspections should be carried out to check for signs of leakage, corrosion, or mechanical stress. The lever handle should move smoothly without resistance, indicating that the internal components remain undamaged. If irregularities occur, disassemble the valve carefully and inspect the sealing surfaces and PTFE rings for wear or contamination.
While the valve is designed for long-term use with minimal intervention, ensure that it is operated within its specified pressure and temperature limits. Avoid using excessive force when turning the lever, as this may cause premature wear of the internal mechanisms. No specific service intervals are provided, but annual checks are recommended for systems subject to frequent use or harsh conditions.
Frequently asked questions
Can the TYTAN valve be used in a central heating system?
Yes, it is suitable for central heating systems due to its maximum operating temperature of 120°C and pressure rating of 30 bar.
Is the lever handle adjustable in position?
The lever handle is fixed during installation and should be oriented for ease of access and smooth operation.
What type of sealing material is used in the valve?
The sealing surface is made of PTFE (teflon), providing a durable and low-friction seal.
Can the valve be used with plastic piping?
Yes, the G3/4'' F-M thread is compatible with plastic piping systems provided that the thread is correctly prepared and sealed.
Additional parameters
| Category: | With union, compression nut and lever handle |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.368 kg |
| EAN: | 5900308747018 |
| Product type: | ball valve / shut-off |
| Thread size: | 3/4" |
| Connection type: | female × male thread |
| Material: | brass |
| Typ: | Guľový ventil so spojkou, plný prierez |
| Pripojenie: | G3/4'' F-M so spojkovou maticou |
| Materiál: | Mosadz, poniklovaná, chrómovaná guľa |
| Tesnenie: | Teflón (PTFE) |
| Rukoväť: | Oceľová páka, PVC povlak |
| Menovitý tlak: | 30 barov |
| Max. teplota: | 120 °C |
| Hmotnosť: | 0,368 kg |
| Záruka: | 2 roky |
Discussion