Assembly distributor IVAR.CS 553 D, 5-way
Code: 553673Related products
Product detailed description
The IVAR.CS 553 D 5-way distributor assembly is commonly used in residential and commercial buildings where multiple heating zones are required. It is typically integrated into central heating systems that combine radiators and underfloor heating. Installers working on multi-loop systems benefit from the streamlined design that allows for precise flow control and zoning. This assembly ensures even heat distribution across different areas, supporting both manual and automated control strategies.
In installations involving mixed heating systems—such as those combining radiators and underfloor heating—the distributor assembly plays a crucial role in balancing the thermal output of each zone. The inclusion of regulating valves on the distributor and shut-off valves on the collector enables fine-tuning of flow rates and isolation of individual circuits for maintenance or system adjustments. Proper planning is essential to ensure that the assembly is correctly sized and positioned within the overall hydraulic layout.
Technical parameters
| Operating temperature | +120 °C |
|---|---|
| Nominal pressure | PN 10 |
| EAN | 8595145903108 |
| Weight | 4.101 kg |
| Code | 553673 |
| Brand | IVAR |
Installation and connection
The assembly connects via 1 inch threaded connections with external sealing (EK). Prior to installation, verify that all branch circuits are correctly aligned with the distributor’s valve positions. Secure the unit using the provided mounting brackets, ensuring it is level and accessible for future adjustments. Common installation errors include incorrect orientation of the regulating and shut-off valves, which can lead to uneven flow distribution or system imbalance. Always follow the manufacturer’s instructions for tightening torque when securing threaded connections to prevent leaks or damage to the brass body.Compatibility and accessories
This distributor is compatible with standard heating systems using copper or PEX piping. For enhanced control and monitoring, it is recommended to fit temperature and flow meters to support accurate system balancing. Accessories such as mounting brackets are included in the package. Additional components such as insulation sleeves or expansion joints may be needed depending on the system design and local regulations.Technical background for designers
The IVAR.CS 553 D operates as a mechanical flow distributor, directing heated water to individual circuits based on the position of the regulating valves. Constructed from brass (CW617N), the assembly offers good corrosion resistance and long-term durability in wet environments. The material also ensures consistent thermal conductivity and minimal expansion stress under varying temperatures. Integration into the system depends on the hydraulic balance and the presence of a circulation pump. System efficiency is influenced by the precision of the valve settings and the quality of the initial system flush before commissioning.Service and operation
Regular inspection of the valves and connections is recommended to detect early signs of wear or leakage. Check for any blockages in the flow paths, especially after system shutdown or during seasonal maintenance. Ensure that all valves operate smoothly and that there are no signs of corrosion or scaling on the internal surfaces. Although no specific service intervals are defined, a thorough cleaning and re-flushing of the system is advised before each heating season to maintain performance and prevent long-term damage caused by debris or chemical residues.Frequently asked questions
Can the IVAR.CS 553 D be used with underfloor heating systems?
Yes, the distributor is suitable for systems that combine radiators and underfloor heating. However, additional flow control measures may be necessary to balance the different thermal responses of the two heating methods.
Is it possible to replace individual valves on the assembly?
Individual valves can be replaced if damaged or worn, provided the replacement parts are compatible with the existing assembly and meet the system requirements.
What is the recommended method for system flushing?
System flushing should be performed according to the manufacturer’s guidelines. This involves draining the system, cleaning the internal components and refilling with treated water to remove any contaminants that could affect performance or longevity.
Can this distributor be mounted vertically?
While the distributor is typically mounted horizontally, vertical mounting is possible if the system design allows and the manufacturer’s guidelines are followed to ensure proper flow and accessibility for maintenance.
Additional parameters
| Category: | IVAR.CS 553 D - manifold/collector assembly without cabinet |
|---|---|
| Warranty: | 2 years |
| Weight: | 4.101 kg |
| EAN: | 8595145903108 |
| Product type: | manifold / header |
| Nominal pressure: | PN 10 |
| Operating temperature: | +120 °C |
| Posledná aktuálizacia ceny: | 23.06.2026 11:26:01 |
Discussion