Heating distributors are essential components in multi-circuit hydronic systems, particularly in residential and commercial buildings with radiators or combined floor and radiator heating. Installers and system designers use these units to balance flow and ensure even heat distribution across multiple zones. The IVAR.CS 553 D is commonly used in systems where precise control of individual circuits is required, such as in multi-room buildings or systems with mixed heating solutions.

When integrating a distributor into a system, the installer must ensure compatibility with the boiler, pump, and existing piping. The unit is typically mounted in a central location, such as a mechanical room or utility area, and connected to the main supply and return lines. The 9-way configuration allows for multiple circuits to be controlled independently, which is particularly useful in systems with varying heat demands across different zones.

Technical parameters

Operating temperature+120 °C
Nominal pressurePN 10
EAN8595145903221
Weight6.736 kg
Code553677
BrandIVAR
The operating temperature of +120°C and nominal pressure of PN 10 are key factors in determining the suitability of the distributor for specific applications. These parameters ensure the unit can handle typical domestic heating conditions, including those involving mixed systems with floor heating and radiators. The pressure rating also affects the type of pump and boiler that can be used in conjunction with the distributor.

Installation and connection

The IVAR.CS 553 D is connected using 1 inch threaded connections. Installers should verify that the main supply and return lines are correctly sized and that the distributor is mounted in a stable, accessible location. The unit should be aligned with the flow direction indicated on the body. Common installation errors include incorrect orientation, failure to secure mounting brackets, and not bleeding the system after installation. It is also important to ensure that the distributor is level to prevent uneven flow distribution.

Compatibility and accessories

This distributor is compatible with standard radiators and floor heating systems. For optimal performance, it is recommended to use it with temperature and flow meters to facilitate accurate system balancing. Additional components such as mounting brackets are included in the set. No other accessories are required for basic installation, but advanced systems may require additional instrumentation.

Technical background for designers

The IVAR.CS 553 D operates by distributing heated water from the main supply line to multiple circuits via individual valves. The distributor is constructed from brass CW617N, a material known for its durability and resistance to corrosion. The design allows for precise flow control, which is essential for achieving balanced heat distribution. The integration of regulating and shut-off valves ensures that each circuit can be adjusted independently, which is particularly important in systems with varying heat loads. The longevity and efficiency of the unit depend on the quality of the installation and the cleanliness of the system during commissioning.

Service and operation

Routine maintenance is not required for the IVAR.CS 553 D, but it is important to periodically check for leaks and ensure that all valves are functioning correctly. Before commissioning the system, especially in mixed heating applications, the system should be flushed according to the manufacturer's instructions. This helps prevent blockages and ensures long-term reliability. No specific service intervals are provided in the technical documentation.

Frequently asked questions

Can the IVAR.CS 553 D be used in a mixed floor and radiator heating system?
Yes, the distributor is suitable for mixed systems. However, it is recommended to install temperature and flow meters to ensure accurate balancing.

Is it necessary to install temperature and flow meters with this distributor?
While not mandatory, it is recommended to install them for easier system balancing and monitoring of flow rates and temperatures.

Can the distributor be mounted vertically?
No, the unit should be mounted horizontally to ensure even flow distribution and proper operation of the valves.

What is the recommended procedure for system commissioning?
Before commissioning, the system should be thoroughly flushed to remove any debris. This is especially important in mixed heating systems to prevent blockages and ensure long-term performance.

Additional parameters

Category: IVAR.CS 553 D - manifold/collector assembly without cabinet
Warranty: 2 years
Weight: 6.736 kg
EAN: 8595145903221
Product type: manifold / header
Nominal pressure: PN 10
Operating temperature: +120 °C
Posledná aktuálizacia ceny: 23.06.2026 11:26:01

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.