Wholesale e-shop

Assembly distributor IVAR.CS 553 VP, 9-way

Code: 553977
naparovana cena na magic
–20 %
Vykurovacia technika Zostava rozdeľovač/zberač- pre podlahové vykurovanie - skriňa  P-KLASIK 3 - 1"xEK; 9cestný; mosadz
–20 % €543,20 / pcs €668,14 incl. VAT Measure price:
In stock

Detailed information

Product detailed description

Floor heating systems in residential and commercial buildings require precise flow distribution to ensure even heat output across all zones. The IVAR.CS 553 VP 9-way distributor is commonly used in multi-room systems where individual temperature control is required. It is particularly suited for installations where floor heating is combined with other heating methods, such as radiators. Installers working on new builds or renovations will find this unit suitable for central heating systems with multiple loops, ensuring balanced flow rates and pressure stability.

When integrating this distributor into a system, it is important to consider the overall hydraulic balance. The unit is designed to work with standard floor heating manifolds and is compatible with copper or PEX piping. The inclusion of flow control meters allows for fine-tuning of each circuit, while the shut-off valves on the collector provide isolation for maintenance or repairs. The unit is typically mounted on a wall near the boiler or in a dedicated mechanical room.

Technical parameters

Nominal pressurePN 10
EAN8595145905218
Weight20.178 kg
Code553977
BrandIVAR

The nominal pressure rating of PN 10 indicates the maximum pressure the unit can safely handle under normal operating conditions. The operating temperature limit of +90°C is typical for floor heating systems using glycol or water as the heat transfer medium. These parameters are essential for ensuring compatibility with the boiler, pump and piping materials. The distributor is suitable for systems with moderate pressure and temperature requirements.

Installation and connection

Installation begins with securing the distributor to a wall using the included mounting brackets. The unit features 1 inch threaded connections on the inlet and 1 inch external connections on the outlets. It is important to ensure that all connections are tightened to the manufacturer's torque specifications to prevent leaks. The ball valves should be fully open during commissioning to allow unrestricted flow. A common mistake is failing to bleed the system after installation, which can lead to air pockets and reduced efficiency. Always verify the alignment of the flow meters and ensure that the collector valves are accessible for future maintenance.

Compatibility and accessories

This distributor is compatible with standard floor heating systems using copper or PEX piping. It is designed to work with thermostatic valves and room controllers for zoned temperature management. Additional components such as expansion vessels, pressure relief valves and circulation pumps may be required depending on the system configuration. The unit is not supplied with a circulation pump, so one must be sourced separately if needed. No specific related products are recommended for this model.

Technical background for designers

The IVAR.CS 553 VP operates as a passive distribution unit, allowing for manual flow adjustment via the integrated flow control meters. The brass construction (CW617N) ensures corrosion resistance and long-term durability in water-based systems. The unit is designed to maintain a stable pressure drop across the manifold, which is important for maintaining system efficiency. The inclusion of automatic air vents and drain valves helps reduce maintenance requirements. The service life of the unit is influenced by the quality of the water in the system and the frequency of maintenance checks.

Service and operation

Periodic maintenance is recommended to ensure the continued performance of the distributor. This includes checking for leaks at all connections, verifying the operation of the flow meters and ensuring that the shut-off valves open and close smoothly. The automatic air vents should be inspected for blockages and drained if necessary. The system should be flushed according to the manufacturer's instructions before commissioning, especially when combining floor heating with other heating methods. No specific service intervals are provided in the brief.

Frequently asked questions

Can the IVAR.CS 553 VP be used with a circulation pump?
Yes, the unit is compatible with external circulation pumps. However, the pump must be connected separately as the distributor does not include one.

Is it possible to integrate this distributor into a mixed heating system with radiators?
Yes, the unit is suitable for mixed systems. However, it is important to ensure proper balancing and flushing of the system to avoid issues with flow distribution.

Can the flow meters be replaced individually?
Yes, the flow meters are designed for individual replacement. They should be replaced if they show signs of wear or inaccurate readings.

Are the shut-off valves on the collector suitable for isolation during repairs?
Yes, the shut-off valves are designed for isolation of individual circuits. They should be closed before any maintenance work is carried out on a specific loop.

Additional parameters

Category: IVAR CS 553 VP without pump
Warranty: 2 years
Weight: 20.178 kg
EAN: 8595145905218
Product type: manifold / header
Nominal pressure: PN 10
Posledná aktuálizacia ceny: 13.04.2026 1:09:14

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.