Boiler Cleaner - 10-15%; 10kg GEL.BOILER CLEANER P.Z.
Code: 113.070.50Related products
Product detailed description
Boiler systems in commercial and industrial buildings often accumulate scale deposits over time, particularly in heat exchangers. These deposits reduce heat transfer efficiency and can lead to system failures if not regularly maintained. Installers and service technicians working in heating and plumbing systems need a reliable solution to dissolve and remove these deposits safely without damaging the materials of the heat exchanger. IVAR 113.070.50 is a professional-grade boiler cleaner designed for use in such environments, ensuring effective cleaning while protecting the integrity of the system components.
This product is commonly used in systems where the heat exchanger is made of copper, steel, stainless steel, aluminium, brass, zinc, or light alloys. The cleaner is mixed with water to form a solution that is circulated through the system to dissolve scale deposits. The process requires careful monitoring of the pH level to ensure optimal cleaning and prevent corrosion. After cleaning, a neutralising solution is used to remove residual acids and stabilise the system before it is put back into operation.
Technical parameters
| Code | 113.070.50 |
|---|---|
| Brand | IVAR |
Installation and connection
The installation process involves preparing the cleaning solution by mixing the powder with water in a suitable container. The solution is then pumped into the system and circulated through the heat exchanger. It is important to ensure that all connections are secure and that the system is isolated from the rest of the building’s heating network to prevent contamination. Common installation mistakes include incorrect mixing ratios, failure to monitor pH levels, and not allowing sufficient time for the solution to work. Technicians should also check that the system is properly drained after cleaning to prevent residual solution from remaining in the heat exchanger.
Compatibility and accessories
IVAR 113.070.50 is compatible with copper, steel, stainless steel, aluminium, brass, zinc, and light alloys. It is specifically formulated with a corrosion inhibitor and reduced gas development to protect these materials during the cleaning process. For complete cleaning, the neutralising solution GEL.BOILER CLEANER N should also be used after the acidic cleaning solution. No additional accessories are required, but a pH meter is necessary for monitoring the solution during the process.
Technical background for designers
The operating principle of IVAR 113.070.50 is based on the chemical dissolution of scale deposits using an acidic solution. The powder is mixed with water to form a solution that is circulated through the heat exchanger. The solution reacts with the scale deposits, breaking them down into soluble compounds that can be flushed out of the system. The product includes a corrosion inhibitor to protect the heat exchanger materials from damage during the cleaning process. The integration of this product into the system requires careful planning to ensure that the cleaning solution can be introduced and removed without disrupting the system’s operation. The efficiency of the cleaning process depends on the correct concentration of the solution, the duration of the cleaning cycle, and the pH level maintained during the process.
Service and operation
After the cleaning process, the system must be thoroughly rinsed with water to remove any residual cleaning solution. A neutralising solution should then be introduced to stabilise the system and prevent residual acidity from causing corrosion. The pH level of the neutralising solution is 13, and it should be circulated through the system before it is returned to normal operation. Regular maintenance intervals depend on the frequency of use and the water quality in the area. Technicians should also inspect the heat exchanger for signs of wear or damage after each cleaning cycle.
Frequently asked questions
Can IVAR 113.070.50 be used on heat exchangers made of zinc?
Yes, the product contains a specific inhibitor for zinc, making it suitable for use on heat exchangers made of this material.
Is a pH meter required during the cleaning process?
Yes, the pH level must be continuously monitored with a pH meter to ensure the solution remains within the correct range for effective cleaning and material protection.
What is the purpose of the neutralising solution?
The neutralising solution is used to remove residual acids after the cleaning process and to stabilise the system before it is put back into operation.
Can this product be used in systems with light alloys?
Yes, the product is suitable for systems with light alloys and includes a corrosion inhibitor to protect these materials during the cleaning process.
Additional parameters
| Category: | Chemicals |
|---|---|
| Weight: | 10 kg |
| Posledná aktuálizacia ceny: | 13.04.2026 1:07:37 |