Wholesale e-shop

Manifold/collector assembly - for underfloor heating - cabinet N-KLASIK 3 - 1 "xEK; 9-way; brass IVAR.CS 553 VP

Code: 553977N
naparovana cena na magic
–20 %
Vykurovacia technika Zostava rozdeľovač/zberač - pre podlahové vykurovanie - skriňa N-KLASIK 3 - 1"xEK; 9cestný; mosadz
–20 % €543,20 / pcs €668,14 incl. VAT Measure price:
In stock at supplier (1–2 weeks)

Detailed information

Product detailed description

Underfloor heating systems require precise flow distribution to maintain thermal comfort and energy efficiency. This 9-way manifold assembly provides individual control over multiple heating loops. Installers working on residential, commercial and industrial projects will find this brass manifold suitable for both new constructions and system retrofits. The compact cabinet design allows for neat installation in mechanical rooms, utility areas or behind access panels. Proper installation ensures even heat distribution across all connected floor zones.

The manifold assembly connects to the primary heating circuit and distributes heated water to individual underfloor loops. Each circuit requires careful balancing to account for differences in pipe length and floor area. The brass construction provides long-term reliability in wet heating environments. Installers should verify system pressure ratings and ensure proper insulation of exposed piping to maintain efficiency.

Technical parameters

Code553977N
BrandIVAR
This 9-way manifold has 1 inch connections for integration with standard heating pipework. The brass construction withstands typical heating system pressures and temperatures. The cabinet provides mechanical protection while allowing access for maintenance and adjustments. These parameters determine compatibility with existing pipework and system design requirements.

Installation and connection

Begin by positioning the cabinet in an accessible location with sufficient clearance for pipe connections. Use appropriate sealing compounds on threaded connections to prevent leaks. The 1 inch connections require standard pipe fittings for secure attachment to the heating circuit. Verify that all connections are tightened to manufacturer specifications. Check for alignment between manifold ports and corresponding loop pipes before final tightening. Common errors include incorrect orientation of flow direction indicators and inadequate support for flexible connecting hoses.

After physical installation, perform a pressure test on the complete system to identify any leaks. Balance the manifold by adjusting individual port valves according to system requirements. Ensure that all access panels remain securely closed during operation to protect internal components. Regular visual inspections should confirm that all connections remain tight and free from corrosion.

Compatibility and accessories

This manifold requires standard 1 inch pipe fittings for connection to the heating circuit. Additional components such as balancing valves, pressure gauges and temperature sensors may be needed depending on system requirements. The brass construction is compatible with most common heating fluids used in underfloor systems. Installers should ensure that all supplementary components meet the same pressure and temperature ratings as the manifold itself.

Technical background for designers

The manifold operates by dividing the main heating circuit into multiple controlled branches. The cabinet design protects internal components from mechanical damage while allowing airflow for thermal management. System efficiency depends on proper sizing of each loop relative to the manifold's capacity. Longer pipe runs require more precise balancing to compensate for pressure losses. The number of circuits directly affects the overall system response time and thermal uniformity.

Service and operation

Periodic inspection of all connections is recommended to detect early signs of leakage. Check valve operation to ensure consistent flow regulation across all circuits. Look for signs of scale buildup in visible components which could indicate water quality issues. Clean external surfaces regularly to remove dust and debris that might interfere with access panel operation. Monitor system performance to identify any changes in heat distribution patterns that might suggest blockages or imbalances.

Frequently asked questions

Can this manifold be used with radiant heating systems?
This manifold is specifically designed for underfloor heating applications and may not be suitable for other types of radiant heating systems without additional modifications.

What type of sealing compound should be used for the connections?
Use a sealing compound compatible with brass components and the specific pipe material being connected to ensure leak-free performance.

How should the manifold be oriented during installation?
Follow the flow direction indicators on the manifold body to ensure correct orientation relative to the heating circuit.

What maintenance is required for the brass components?
Regular visual inspections are sufficient for brass components. Look for signs of corrosion or mechanical damage that might affect performance.

Additional parameters

Category: IVAR CS 553 VP without pump
Weight: 15.27 kg
Product type: manifold / header
Thread size: 1"
Connection type: female thread
Material: brass
Posledná aktuálizacia ceny: 13.04.2026 1:10:19

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.