Wholesale e-shop

Manifold/collector assembly - without housing - 5/4 "xEK; 5-way; brass IVAR.CS 553 D

Code: 400285
naparovana cena na magic
–20 %
Vykurovacia technika Zostava rozdeľovač/zberač - bez skrine - 5/4"xEK; 5cestný; mosadz
–20 % €196,80 / pcs €242,06 incl. VAT Measure price:

Detailed information

Product detailed description

Manifold/collector assemblies are essential components in hydronic heating systems, particularly in commercial and residential buildings with multiple heating circuits. They serve as central distribution and collection points for hot water, ensuring balanced flow and efficient operation. Installers working with radiator-based heating systems or mixed systems with underfloor heating will benefit from the modular design and precise flow control offered by this assembly.

Correct selection and installation of manifold/collector assemblies are critical for system performance. This unit is suitable for systems operating at up to +120 °C and PN10 pressure ratings. It is typically used in systems where zoning and individual circuit control are required, such as in multi-room residential buildings or small commercial facilities.

Technical parameters

MaterialBrass CW617N
Operating temperature+120 °C
Nominal pressurePN 10
Code400285
BrandIVAR

The operating temperature of +120 °C and PN10 pressure rating are key factors in determining the suitability of this manifold for specific applications. These parameters ensure compatibility with standard heating systems using water as the heat transfer medium. The brass CW617N material is selected for its corrosion resistance and mechanical strength under typical operating conditions.

Installation and connection

Installation involves connecting the distributor and collector to the main heating circuit using 5/4 inch EK threaded connections. The assembly includes mounting brackets for secure installation on walls or within mechanical rooms. It is important to ensure that all connections are tightened to the manufacturer's torque specifications and that the system is purged of debris before commissioning. Common installation errors include incorrect orientation of the valves and failure to align the flow direction as indicated on the body of the manifold.

Compatibility and accessories

This manifold is compatible with standard heating systems using water as the heat transfer medium. It is typically used in conjunction with radiators or underfloor heating circuits. For complete system integration, additional components such as insulation, mounting brackets, and control valves may be required. The assembly is designed to work with standard pipe sizes and fittings commonly used in heating installations.

Technical background for designers

The manifold operates by dividing the incoming hot water flow into multiple circuits and collecting the return flow from each circuit. The brass CW617N material provides good thermal conductivity and resistance to corrosion in water-based systems. The design allows for individual circuit balancing and isolation, which is essential for maintaining system efficiency and preventing thermal imbalances. The performance of the manifold is influenced by the quality of the water in the system and the presence of particulate matter, which can affect valve operation and flow distribution.

Service and operation

Regular inspection of the manifold is recommended to ensure that all valves operate smoothly and that there are no signs of leakage or corrosion. The manufacturer recommends a system flush before commissioning, especially when combining different types of heating circuits. This helps to remove any debris that could affect the performance of the valves. No specific service intervals are provided, but any issues with flow or pressure should be investigated promptly to prevent system inefficiencies.

Frequently asked questions

Can this manifold be used with underfloor heating systems?
Yes, this manifold can be used with underfloor heating systems, provided the system is designed to operate within the specified temperature and pressure limits.

Is it possible to replace individual valves on the manifold?
Individual valves can be replaced if they become faulty, but it is important to ensure that the replacement valves are compatible with the manifold's design and specifications.

What is the recommended method for purging the system before commissioning?
The manufacturer recommends a thorough system flush according to the manufacturer's instructions to remove any debris that could affect the performance of the valves.

Can this manifold be used with a condensing boiler?
Yes, this manifold is compatible with condensing boilers as long as the system operates within the specified temperature and pressure limits.

Additional parameters

Category: IVAR.CS 553 D - manifold/collector assembly without cabinet
Weight: 5.95 kg
Product type: manifold / header
Thread size: 5/4"
Material: copper / bronze
Material: brass CW617N
Nominal pressure: PN 10
Operating temperature: +120 °C
Posledná aktuálizacia ceny: 27.04.2026 3:21:06

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.