Manifold - fitted with control flow meters - 1 "xEK; 4-way; brass IVAR.CI 553 VP
Code: 501762Related products
Product detailed description
Manifolds with integrated flow meters are essential components in hydronic heating systems, particularly in underfloor heating applications. These units enable accurate distribution and regulation of hot water across multiple circuits. Installers working in residential and commercial buildings often encounter systems requiring individual circuit balancing to ensure even heat distribution. This 4-way model is commonly used in medium-sized installations where four separate heating zones need independent control.
The brass construction provides durability and resistance to corrosion in wet environments. The flow meters allow for precise adjustment of water flow rates, ensuring optimal performance and energy efficiency. The unit connects to the main supply via side inlets and distributes flow through four outlets spaced 50 mm apart. Proper installation requires attention to system flushing and compatibility with other components such as valves and insulation layers.
Technical parameters
| Material | Brass CW617N |
|---|---|
| Operating temperature | +90 °C |
| Nominal pressure | PN 10 |
| Outlet spacing | 50 mm |
| EAN | 8595145900244 |
| Weight | 1.594 kg |
| Code | 501762 |
| Brand | IVAR |
Installation and connection
Installers should begin by verifying the correct orientation of the manifold body and ensuring all inlet and outlet connections are clean and undamaged. The side inlets are 1 inch female threaded, while the four outlets are 3/4 inch external connections. Each outlet must be securely tightened using appropriate sealing tape or compound to prevent leaks. The 50 mm spacing between outlets must align with the planned distribution layout to avoid misalignment with collector pipes or valves.
A critical step is to flush the entire system thoroughly before commissioning, especially when combining floor heating with radiator systems. Failure to remove debris can lead to blockages or inaccurate flow meter readings. Common installation errors include incorrect thread sealing, misaligned outlet positions, and insufficient support for the manifold body. Always follow the manufacturer’s instructions for system preparation and flushing procedures.
Compatibility and accessories
This manifold is compatible with standard floor heating systems using 3/4 inch piping. Additional components such as insulation plates, balancing valves, and temperature sensors may be required depending on the system design. Installers should also consider the need for expansion joints or vibration dampers in larger installations to accommodate thermal movement. No specific related products are listed for this model, but compatibility with IVAR’s range of heating system components is expected.
Technical background for designers
The manifold operates by dividing the incoming hot water into four controlled streams. The CW617N brass material offers high resistance to corrosion and thermal stress, making it suitable for long-term use in closed heating systems. The integrated flow meters allow for fine-tuning of flow rates per circuit, which is crucial for achieving balanced heat distribution. Designers should account for the pressure drop across the manifold when sizing pumps and selecting pipe diameters. System efficiency is influenced by the accuracy of flow meter calibration and the overall system layout.
Thermal expansion and contraction of the manifold body can affect the integrity of connections over time. Proper insulation and expansion management are necessary to maintain system efficiency. The PN10 pressure rating indicates the maximum allowable working pressure, which must be considered during system design to prevent mechanical failure.
Service and operation
Regular maintenance includes visual inspection of connections for leaks and checking the integrity of flow meters. Although no specific service intervals are provided, periodic verification of flow meter readings is recommended to ensure accurate balancing. Any signs of corrosion or wear on the brass body should be addressed immediately. If the system has been flushed or modified, recalibration of flow meters may be necessary.
During operation, installers should monitor system performance for uneven heating or pressure fluctuations. If flow meter readings drift outside the expected range, the unit may require cleaning or replacement. The manufacturer recommends using the GEL.LONG LIFE 100 treatment to protect against internal corrosion and extend service life.
Frequently asked questions
Can this manifold be used in mixed floor and radiator heating systems?
Yes, but special attention must be given to system flushing and balancing to prevent interference between different heating circuits.
Are the flow meters adjustable after installation?
Yes, the flow meters allow for manual adjustment within the specified range to balance the flow in each circuit.
What is the recommended method for sealing the connections?
Use high-quality sealing tape or compound on all threaded connections to ensure a leak-free installation.
Is this model suitable for use with glycol-based heating fluids?
According to the manufacturer’s technical data sheet, compatibility with glycol-based fluids should be verified separately.
Additional parameters
| Category: | IVAR.CI 553 VP - manifold with regulating flow meters |
|---|---|
| Warranty: | 2 years |
| Weight: | 1.594 kg |
| EAN: | 8595145900244 |
| Product type: | manifold / header |
| Thread size: | 1" |
| Connection type: | compression fitting |
| Material: | brass |
| Material: | brass CW617N |
| Nominal pressure: | PN 10 |
| Operating temperature: | +90 °C |
| Outlet spacing: | 50 mm |