Safety valve IVAR.PV 527, 1" F x 5/4" F; 2,5 bar
Code: 527625Related products
Product detailed description
Safety valves are essential components in heating systems to prevent overpressure situations that could damage equipment or pose safety risks. The IVAR.PV 527 is designed for installation in central heating systems where pressure regulation is required. It is commonly used in residential and commercial buildings, particularly in systems with boilers, heat exchangers and circulation pumps. Installers working on heating circuits, especially those involving expansion vessels or closed-loop systems, will find this valve suitable for maintaining safe operating conditions. The valve is intended for use in environments where the operating temperature remains stable and within standard heating system parameters.
Correct installation and sizing of the valve are critical to ensure it functions as intended. The valve must be positioned in a location that allows for easy access for inspection and maintenance. It should be installed in a horizontal or vertical orientation, depending on the system layout, and oriented so that the flow direction matches the manufacturer's specifications. The valve should be mounted in a way that minimises stress on the connections and ensures a secure fit with the adjacent piping.
Technical parameters
| Material | Brass CB753S |
|---|---|
| Operating temperature | +5 °C |
| Nominal pressure | PN 10 |
| EAN | 8016615013160 |
| Weight | 1.222 kg |
| Code | 527625 |
| Brand | IVAR |
The nominal pressure rating of PN 10 indicates the valve is suitable for systems operating at up to 10 bar. The operating temperature of +5 °C is a key factor in determining compatibility with the system's thermal conditions. The material, CB753S brass, is selected for its resistance to corrosion and mechanical strength. These parameters are essential for ensuring the valve can handle the expected load and environmental conditions without failure.
Installation and connection
The IVAR.PV 527 has 1 inch F x 5/4 inch F threaded connections, which must be matched with compatible pipe fittings. Installers should verify that the threads are clean and undamaged before assembly. A sealing compound or thread tape should be applied to ensure a leak-free connection. The valve should be installed in a location that allows for unimpeded flow and easy access for inspection. Common installation errors include incorrect orientation, failure to align the flow direction, and using incompatible sealing materials. After installation, the system should be tested for leaks and the valve's operation verified by simulating a pressure increase to confirm it opens at the specified 2.5 bar.
Compatibility and accessories
This valve is compatible with standard heating system components such as expansion vessels, pressure-reducing valves and pressure switches. When integrating the valve into a system, it is important to ensure that the upstream and downstream piping is correctly sized and that the system's pressure settings align with the valve's opening pressure. No additional accessories are required for basic installation, but pressure gauges or monitoring devices may be added for enhanced system control. No related products are available for this model.
Technical background for designers
The IVAR.PV 527 operates by allowing excess pressure to escape when the system pressure exceeds the set threshold of 2.5 bar. The valve is spring-loaded and designed to open automatically when the pressure differential reaches the specified level. The CB753S brass material provides good resistance to thermal expansion and corrosion, making it suitable for long-term use in heating systems. The valve's integration into the system depends on the overall pressure management strategy, including the use of expansion vessels and pressure-reducing devices. The service life and efficiency of the valve are influenced by the frequency of pressure fluctuations, the quality of installation and the maintenance of the surrounding system components.
Service and operation
Regular inspection of the valve is recommended to ensure it remains functional and free from blockages. The valve should be checked for signs of wear, leakage or corrosion. The operating pressure should be verified periodically to confirm the valve opens at the correct pressure. No specific service intervals are provided in the technical data. If the valve fails to operate correctly, it should be replaced immediately to prevent system overpressure.
Frequently asked questions
Can the IVAR.PV 527 be used in closed-loop heating systems?
Yes, the valve is suitable for closed-loop systems where pressure regulation is required. It should be installed in accordance with the system's pressure management strategy.
What is the maximum operating temperature for this valve?
The valve is rated for an operating temperature of +5 °C. For higher temperatures, consult the manufacturer's technical data sheet.
Is the valve compatible with copper piping?
Yes, the valve can be connected to copper piping using the specified 1 inch F x 5/4 inch F threaded connections. Ensure the threads are properly sealed.
Can the opening pressure be adjusted after installation?
No, the valve is factory-set to open at 2.5 bar and is not user-adjustable. If a different pressure setting is required, a different model should be selected.
Additional parameters
| Category: | IVAR.PV 527 - for heating |
|---|---|
| Warranty: | 2 years |
| Weight: | 1.222 kg |
| EAN: | 8016615013160 |
| Product type: | safety valve |
| Thread size: | 1" |
| Connection type: | female thread |
| Material: | brass |
| Material: | brass CB753S |
| Nominal pressure: | PN 10 |
| Operating temperature: | +5 °C |
| Posledná aktuálizacia ceny: | 19.06.2026 8:37:22 |