The IVAR.CS 553 VP 4-way distributor is commonly used in residential and commercial hydronic heating systems. It provides a central point for distributing heated water to multiple floor heating loops. Installers working on underfloor heating systems often integrate this distributor into systems that require precise flow control and individual loop management. The unit is suitable for applications where the system operates at a nominal pressure of PN 10 and a maximum temperature of 90°C. It is particularly useful in systems where floor heating is combined with other heating elements such as radiators.

Typical installation scenarios include new builds, renovations and system upgrades. The distributor is mounted in accessible locations to allow for maintenance and adjustments. It is often used in conjunction with a boiler or heat pump and requires proper hydraulic balancing to ensure even heat distribution across all connected zones. The inclusion of flow meters and shut-off valves allows for individual loop control and monitoring.

Technical parameters

Nominal pressurePN 10
EAN8595145905065
Weight12.997 kg
Code553972
BrandIVAR
The nominal pressure rating of PN 10 indicates the maximum pressure the distributor can handle under normal operating conditions. This is a critical factor when sizing the system and selecting compatible components. The maximum operating temperature of 90°C must be considered when designing the system to ensure compatibility with other components such as pipes and valves. These parameters are essential for ensuring the distributor functions correctly within the intended system environment.

Installation and connection

Installation begins with positioning the distributor in a suitable location, typically on a wall or floor, with adequate space for access. The distributor has 1 inch connections with EK thread type for both inlet and outlet. Installers should verify that all connections are properly sealed and that the mounting brackets are correctly attached to prevent vibration and movement. Common installation mistakes include incorrect orientation of the flow meters and improper sealing of the connections, which can lead to leaks or inaccurate flow readings. It is important to follow the manufacturer's instructions for mounting and alignment to ensure proper function.

Compatibility and accessories

The IVAR.CS 553 VP is compatible with standard hydronic heating systems that operate within the specified pressure and temperature limits. It is designed to work with copper or PEX piping and requires compatible valves and fittings for connection. Accessories such as ball valves, flow meters and shut-off valves are included in the package. Additional components that may need to be ordered separately include insulation materials, mounting hardware and pipe fittings. The distributor is not equipped with a pump and must be connected to an external circulation system.

Technical background for designers

The distributor operates by dividing the incoming hot water flow into multiple branches, each connected to a separate heating loop. The flow meters allow for individual loop control and monitoring, ensuring even heat distribution. The distributor is constructed from durable materials such as brass (CW617N) for the valves and fittings, which provides resistance to corrosion and wear. The integration of the distributor into the system depends on the overall hydraulic design, including pipe sizing and pump capacity. The service life and efficiency of the distributor are influenced by the quality of the installation, regular maintenance and the use of system purging and treatment products such as GEL.LONG LIFE 100.

Service and operation

Regular maintenance is essential to ensure the distributor functions correctly. This includes checking for leaks, verifying the operation of the flow meters and shut-off valves, and ensuring that the system is free from debris. The manufacturer recommends purging the system before commissioning, especially when combining floor heating with other heating systems. The use of system treatment products is also advised to prevent blockages and corrosion. There are no specific service intervals provided, but routine inspections are recommended to identify and address potential issues early.

Frequently asked questions

Can the IVAR.CS 553 VP be used with a heat pump system?
Yes, the distributor is compatible with heat pump systems as long as the operating pressure and temperature remain within the specified limits of PN 10 and 90°C.

Are the flow meters adjustable?
The flow meters are designed for accurate measurement and are not intended to be adjusted manually. They provide a reference for flow control in each loop.

Can the distributor be used in a system with both floor heating and radiators?
Yes, but the manufacturer strongly recommends purging the entire system before commissioning to prevent blockages caused by debris.

What material is used for the valves and fittings?
The valves and fittings are made from brass (CW617N), which offers good resistance to corrosion and wear.

Additional parameters

Category: IVAR CS 553 VP without pump
Warranty: 2 years
Weight: 12.997 kg
EAN: 8595145905065
Product type: manifold / header
Nominal pressure: PN 10
Posledná aktuálizacia ceny: 13.04.2026 1:04:22

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.