Safety relief groups are essential components in heating systems, ensuring safe operation by monitoring and releasing excess pressure when necessary. These groups are typically found in residential and commercial buildings where central heating systems require regular pressure control and safety mechanisms. Installers working on such systems need reliable solutions that integrate seamlessly with existing piping and provide accurate readings during normal operation and emergency conditions.

When installing or replacing a safety relief group, the system’s hydraulic balance and pressure settings must be considered. This ensures that the group functions correctly under varying load conditions and does not interfere with the overall performance of the heating system. The installation should be carried out in accordance with local standards and the manufacturer’s guidelines to avoid leaks or incorrect readings.

Technical parameters

MaterialBrass CB753S
Operating temperature0 °C
Nominal pressurePN 10
EAN8016615002218
Weight0.95 kg
Code302631
BrandIVAR
The nominal pressure rating of PN 10 indicates the maximum allowable pressure under standard operating conditions, which is critical for correct system design and component selection. The operating temperature range from 0°C to 110°C determines suitability for both cold and hot water applications. The brass CB753S material provides good corrosion resistance and mechanical strength, making it suitable for long-term use in heating systems.

Installation and connection

The safety relief group connects via 1-inch threaded ports, requiring compatible fittings for secure installation. Before fitting, ensure the system is depressurised and the installation site is clean and free of debris. Secure the group using the provided bracket and align it vertically for accurate pressure readings. Check all connections for tightness after installation and verify that the automatic air vent functions properly. Common errors include incorrect orientation of the pressure gauge and failure to isolate the system before beginning work.

Compatibility and accessories

This group is compatible with standard heating systems operating within the specified pressure and temperature ranges. Additional components such as isolation valves, expansion tanks, and pipe insulation may be required depending on the system configuration. When designing or expanding a system, ensure that all components are sized appropriately to maintain balanced flow and prevent overpressure scenarios.

Technical background for designers

The safety relief group functions by allowing controlled release of excess pressure through the safety valve once the set threshold is exceeded. The brass construction offers durability and thermal stability, while the integrated pressure gauge enables continuous monitoring. The inclusion of an automatic air vent helps remove trapped air, improving system efficiency. Designers should consider the location of the group to allow easy access for inspection and maintenance, and ensure that the surrounding area accommodates potential discharge during pressure relief events.

Service and operation

Regular visual inspections should be conducted to ensure all components are functioning correctly. Check for signs of corrosion, leakage, or damage to the pressure gauge and safety valve. The automatic air vent should be tested periodically to confirm it opens and closes as intended. While no specific service intervals are provided in the brief, routine maintenance will help extend the product’s operational life and ensure consistent performance.

Frequently asked questions

Can this group be used in solar heating systems?
If the system operates within the specified pressure and temperature range, the group can be integrated provided that additional protection against freeze damage is ensured.

Is a separate pressure gauge required?
No, the unit includes an integrated pressure gauge with a measurement range of 0 to 4 bar, eliminating the need for external instruments.

How is the safety valve activated?
The safety valve opens automatically when the system pressure exceeds the pre-set opening pressure of 3 bar, allowing excess fluid to be released until pressure returns to acceptable levels.

Does the group require electrical power to operate?
No, the unit operates purely mechanically and does not require any electrical supply for pressure monitoring or relief functions.

Additional parameters

Category: Safety groups
Warranty: 2 years
Weight: 0.95 kg
EAN: 8016615002218
Material: brass
Material: brass CB753S
Nominal pressure: PN 10
Operating temperature: 0 °C