Ceiling heating/cooling panel - smooth - 60x60x3cm; steel; passive/perforated IVAR.METAL-CLIMA P
Code: METAL-PFRelated products
Product detailed description
This ceiling heating and cooling panel is designed for integration into suspended or solid ceilings in both residential and commercial buildings. It is commonly used in radiant heating and cooling systems where uniform thermal comfort is required. The panel operates by transferring heat or cold through convection and radiation, depending on the system configuration. Installers typically work with HVAC designers and contractors to ensure correct placement and system compatibility. The panel is suitable for use in offices, retail spaces, and modern residential developments where low-temperature systems are preferred.
The panel is constructed from steel and is available in a smooth surface with either a passive or perforated design. The perforated version enhances air circulation, making it suitable for systems where airflow is a critical factor. The panel is mounted within the ceiling structure and connected to a hydronic system, typically via a manifold and distribution piping. The installation must account for thermal expansion and insulation requirements to prevent heat loss or gain outside the intended space.
Technical parameters
| Code | METAL-PF |
|---|---|
| Brand | IVAR |
Installation and connection
The panel is mounted within the ceiling structure using standard mounting brackets or suspension systems. Connection to the hydronic system is typically achieved via copper or PEX piping, with thread types and sizes determined by the system design. Installers should ensure that the panel is level and that all connections are sealed to prevent leaks. Common installation mistakes include incorrect spacing between panels, which can lead to uneven thermal performance, and failure to insulate the panel edges, which may result in heat loss. It is also important to verify that the system pressure and flow rates are compatible with the panel’s design.Compatibility and accessories
This panel is compatible with low-temperature radiant heating and cooling systems, including those using water at temperatures typical for underfloor or ceiling-based systems. Accessories such as mounting brackets, insulation materials, and sealing compounds are typically required for a complete installation. Additional components may include manifolds, balancing valves, and control systems for zoning and temperature regulation. Related products include other ceiling panels and radiant system components from IVAR.Technical background for designers
The panel operates by transferring heat or cold via convection and radiation. The steel material has high thermal conductivity, allowing for efficient heat transfer. The panel’s performance is influenced by the system’s water temperature, flow rate, and the room’s insulation and occupancy. The perforated design enhances air movement, which can improve thermal comfort in certain applications. The panel is integrated into the system via a manifold, and its placement must be planned to ensure even coverage and avoid thermal bridging. The service life of the panel is affected by the quality of the installation, including proper sealing and insulation, as well as the system’s water quality and maintenance.Service and operation
Regular inspection of the panel and its connections is recommended to ensure there are no leaks or blockages. The system should be flushed periodically to remove debris and maintain flow efficiency. The panel itself requires no direct maintenance, but the surrounding insulation and mounting structure should be checked for damage. Any issues with the system’s performance should be investigated to determine whether they are related to the panel or other components of the system.Frequently asked questions
Can this panel be used in both heating and cooling systems?
Yes, the panel is designed for use in both heating and cooling applications, depending on the system configuration and water temperature.
What is the difference between the passive and perforated versions?
The perforated version allows for greater air circulation, which can improve thermal comfort in certain environments, while the passive version is suitable for applications where minimal airflow is desired.
How is the panel connected to the hydronic system?
The panel is connected via piping, typically using copper or PEX tubing. The connection method and thread types depend on the system design and must be verified during installation.
Can this panel be installed in suspended ceilings?
Yes, the panel is suitable for installation in suspended ceilings, provided that the mounting system is designed to accommodate its dimensions and weight.
Additional parameters
| Category: | Steel |
|---|---|
| Warranty: | 24 months |
| Weight: | 3.5 kg |
| Material: | steel / cast iron |
| Posledná aktuálizacia ceny: | 13.04.2026 1:01:44 |