Wholesale e-shop

Preassembled backflow preventer assembly - series ECO 3T - 3/4 inch; L=448mm BRA.ECO 3T RAMPA T

Code: RAMPAT034
naparovana cena na magic
–20 %
Vykurovacia technika Predmontovaná zostava zamedzovača spätného prietoku - sériaECO 3T - 3/4"; L=448mm
–20 % €827,20 / pcs €1 017,46 incl. VAT Measure price:
To order (1-2 weeks)

Detailed information

Product detailed description

Backflow preventers are essential components in closed-loop heating and plumbing systems where unidirectional flow is required. These devices are commonly used in residential, commercial and industrial buildings to ensure that fluids such as water or glycol mixtures flow in the intended direction. Installers working on central heating systems, underfloor heating circuits or pump stations will encounter these valves in applications where pressure differentials could cause reverse flow. The ECO 3T model is suited for integration into systems with standard pipe layouts and where space constraints require compact valve solutions.

When installing this type of backflow preventer, it is important to consider the system's hydraulic characteristics, including flow rates and pressure drops across the valve. The preassembled nature of this model allows for faster installation compared to manually assembled alternatives, reducing downtime during system commissioning or maintenance. The valve is typically installed in the suction or discharge line of a pump, depending on the system design and the need to isolate the pump from the rest of the circuit.

Technical parameters

CodeRAMPAT034
BrandIVAR
The 3/4 inch connection size and 448mm length are key parameters for determining compatibility with existing pipe layouts and for ensuring correct spacing between adjacent components. These dimensions are particularly relevant when planning the layout of the system and when verifying that the valve can be installed without interference from other components or structural elements. The preassembled configuration also ensures that all internal components are correctly aligned and sealed, reducing the risk of leaks or misalignment during installation.

Installation and connection

The installation procedure begins with verifying the correct orientation of the valve, as backflow preventers are directional and must be installed in the correct flow direction. The 3/4 inch connection requires matching pipe or fitting sizes to ensure a secure and leak-free connection. It is important to check that the mating surfaces are clean and free from debris before tightening the connections. Common installation mistakes include incorrect orientation, insufficient tightening of the connections, or failure to align the valve with the system's flow path. These errors can lead to reduced performance or premature failure of the valve.

Compatibility and accessories

This backflow preventer is compatible with standard heating and plumbing systems that use 3/4 inch piping. It is typically used in conjunction with pumps, expansion vessels, and control valves. When installing, it may be necessary to order additional components such as unions, gaskets or mounting brackets, depending on the system design. No related products are specified for this model.

Technical background for designers

The operating principle of the ECO 3T backflow preventer is based on a check valve mechanism that allows flow in one direction while preventing reverse flow. The valve is constructed from stainless steel, which provides resistance to corrosion and ensures long-term reliability in systems with aggressive fluids. The compact design allows for integration into tight spaces, making it suitable for retrofitting in existing systems. The service life and efficiency of the valve depend on factors such as the quality of the installation, the cleanliness of the fluid, and the absence of excessive vibration or pressure surges in the system.

Service and operation

Regular inspection of the valve is recommended to ensure that it is functioning correctly. Key checkpoints include verifying that the valve is free from blockages, checking for signs of leakage at the connections, and ensuring that the internal components are not damaged. No specific service intervals are provided in the brief, but any signs of malfunction should be addressed promptly to prevent system disruption.

Frequently asked questions

Can the ECO 3T be installed in a vertical orientation?
Yes, the ECO 3T can be installed in a vertical orientation as long as the flow direction is maintained and the valve is aligned with the system's hydraulic requirements.

Is the ECO 3T suitable for use with glycol-based fluids?
Yes, the stainless steel construction of the ECO 3T makes it compatible with glycol-based fluids, provided that the fluid is within the manufacturer's specified operating conditions.

Can the ECO 3T be used in a system with variable flow rates?
Yes, the ECO 3T is designed to function effectively in systems with variable flow rates, as long as the flow remains within the valve's operational limits.

Does the ECO 3T require a separate mounting bracket?
It depends on the system design. In some installations, a mounting bracket may be necessary to secure the valve and prevent vibration-induced stress on the connections.

Additional parameters

Category: BRA.ECO 3F, 3T - Backflow preventers
Weight: 3 kg
Product type: check valve / flap
Thread size: 3/4"
Posledná aktuálizacia ceny: 13.04.2026 1:12:35

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.