Wholesale e-shop

T-piece 54 x 35 x 54

Code: IVC41.543554
naparovana cena na magic
–20 %
Vykurovacia technika T-kus 90° - redukovaný - C - 54-35-54mm
–20 % €17,60 / pcs €21,65 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

This T-piece is commonly used in central heating systems, fire water supply ducts, air-conditioning installations and industrial piping. It is suitable for closed pressurised systems where a branch connection is required. The fitting is designed for use with press connections and is intended for installation in environments where mechanical durability and resistance to high pressure are essential. The operating temperature range allows for use in both cold and hot water systems, as well as in systems with dry air or inert gases.

Typical applications include central heating ducts, cold water and refrigeration systems, fire suppression systems and air-conditioning ducts. The fitting is also suitable for solar system piping. The EPDM O-ring ensures a tight seal, and the absence of surface coating limiting agents means the fitting is suitable for use in systems where such agents could interfere with performance. The fitting is not certified for drinking water applications.

Technical parameters

Materialcarbon galvanized steel
Operating temperature-20 °C
Nominal pressurePN 16
Resistance to high pressures up to16 bar
Weight0.356 kg
CodeIVC41.543554
BrandIVAR
The nominal pressure rating of PN 16 means the fitting is suitable for systems operating up to 16 bar. The operating temperature range from -20 °C to +120 °C allows for use in a wide range of environments, including cold storage and hot water systems. These parameters are essential for ensuring compatibility with the system's design pressure and temperature conditions.Installation and connection The T-piece is connected using press fittings and requires no welding or threaded joints. The connection sizes are 54 mm, 35 mm and 54 mm, and the fitting is compatible with Type M jaws. During installation, it is important to ensure that the molding indicator is visible and that the fitting is fully seated. Common installation mistakes include improper seating of the fitting, which can lead to leaks, and using the wrong jaw type, which can damage the fitting. The installer should also verify that the system pressure does not exceed the PN 16 rating and that the operating temperature remains within the specified range.Compatibility and accessories This T-piece is compatible with other IVAR press fittings and can be integrated into systems using carbon galvanized steel piping. It is essential to use the correct press tools and jaws to ensure a secure connection. Additional components such as straight and elbow fittings may be required depending on the system layout. The fitting is not compatible with systems requiring surface coating limiting agents or those certified for drinking water use.Technical background for designers The T-piece operates by providing a branch connection in a pressurised system. The carbon galvanized steel construction offers resistance to mechanical damage and corrosion, while the EPDM O-ring ensures a tight seal. The material properties allow for use in a wide range of temperatures and pressures, making it suitable for both heating and industrial applications. The integration into the system depends on the system's pressure and temperature requirements, as well as the need for a durable and leak-free connection. The service life is influenced by the operating conditions and the quality of the installation.Service and operation The fitting requires no regular maintenance, but it is important to periodically check for leaks and ensure that the system pressure and temperature remain within the specified limits. If a leak is detected, the fitting should be replaced immediately. The absence of service intervals in the brief indicates that the fitting is designed for long-term use without the need for routine servicing. Proper installation and adherence to the operating parameters are key to ensuring the fitting's performance and longevity.Frequently asked questions

Can this T-piece be used in a solar system?
Yes, the T-piece is suitable for use in solar system piping as it can handle the operating temperatures and pressures typical of such systems.

Is the T-piece compatible with inert gas systems?
Yes, the fitting is suitable for use with inert gases as it is constructed from carbon galvanized steel and features an EPDM O-ring that is compatible with such media.

Can the T-piece be used in fire suppression systems?
Yes, the T-piece is suitable for fire water supply ducts and can be used in fire suppression systems provided the operating conditions remain within the specified parameters.

Is the T-piece suitable for use with dry air?
Yes, the fitting is suitable for use with pressure dry air as it is designed for industrial applications and can handle the required pressure and temperature conditions.

Additional parameters

Category: IVAR.IVC41,IVC44 - t-pieces reduced
Warranty: 2 years
Weight: 0.356 kg
Product type: tee
Pipe diameter: 54 mm
Material: steel / cast iron
High pressure resistance up to: 16 bar
Material: galvanized carbon steel
Nominal pressure: PN 16
Operating temperature: -20 °C
Posledná aktuálizacia ceny: 13.04.2026 1:09:49

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.