Vibration Damping Spacer - Series W8 - DN 20; L=70mm; EPDM BRA.W8.500
Code: W8500020Related products
Product detailed description
Vibration damping spacers are essential components in heating, ventilation, and air conditioning (HVAC) systems, as well as in water and compressed air distribution systems. These systems are commonly found in residential, commercial, and industrial buildings where the transmission of mechanical vibrations and noise through piping can lead to operational inefficiencies and structural stress. Installers and technicians working in these environments often encounter the need to isolate mechanical components from the piping network to ensure smooth operation and longevity of the system.
Vibration damping spacers are particularly useful in systems where pumps, compressors, or other vibrating equipment are connected to the piping. Without proper isolation, these vibrations can propagate through the pipes, causing noise, fatigue, and potential failure of pipe joints or connected equipment. The IVAR W8 series spacers are designed to address these issues by providing a flexible coupling that absorbs and dampens vibrations while maintaining a secure connection between pipe sections.
Technical parameters
| Material: - flanges | Galvanized steel |
|---|---|
| Nominal diameter | DN 20 |
| Nominal pressure | PN 10 |
| Weight | 1.753 kg |
| Code | W8500020 |
| Brand | IVAR |
Installation and connection
Installation of the IVAR W8500020 vibration damping spacer requires careful attention to connection details. The spacer is equipped with flanges that must be aligned with the corresponding flanges on the pipe sections. The nominal diameter (DN 20) ensures compatibility with standard pipe sizes, and the flange type must match the system's requirements. Prior to installation, the installer should verify that the flange surfaces are clean and free of debris to ensure a proper seal. Common installation mistakes include misalignment of the flanges, which can lead to leaks or uneven stress distribution, and improper tightening of the bolts, which can compromise the integrity of the connection.
Compatibility and accessories
This vibration damping spacer is compatible with standard HVAC and plumbing systems that use flanged connections. It is suitable for use with water containing up to 50% glycol, making it appropriate for systems that require antifreeze properties. No additional accessories are required for standard installation, though the system's design may necessitate the use of specific flange types or gaskets depending on the application. Installers should ensure that all components are compatible with the operating conditions of the system, including temperature and pressure requirements.
Technical background for designers
The IVAR W8500020 vibration damping spacer operates by using a flexible EPDM sealing element to absorb mechanical vibrations and reduce noise transmission. The flanged steel construction provides structural support while allowing for slight movement between pipe sections. The choice of EPDM as the sealing material ensures resistance to water and glycol-based fluids, making it suitable for a wide range of HVAC and plumbing applications. The spacer's performance is influenced by factors such as the frequency and amplitude of the vibrations, the operating temperature, and the chemical composition of the fluid in the system. Proper integration into the system requires consideration of these factors to ensure optimal performance and service life.
Service and operation
Regular inspection of the vibration damping spacer is recommended to ensure continued performance. The installer should check for signs of wear, such as cracking or hardening of the EPDM sealing element, which can reduce the spacer's effectiveness. Additionally, the flange connections should be inspected for leaks or misalignment. No specific service intervals are provided in the technical documentation, but maintenance should be performed as part of the system's routine inspection schedule. If any issues are detected, the spacer should be replaced to prevent further damage to the system.
Frequently asked questions
Can the IVAR W8500020 be used in steam systems?
No, this spacer is not suitable for steam systems. The technical documentation specifies that it is not appropriate for use with steam, gases, or fluids containing oils or hydrocarbons.
Is the IVAR W8500020 compatible with water containing glycol?
Yes, the spacer is suitable for use with water containing up to 50% glycol. This makes it appropriate for systems that require antifreeze properties.
What is the maximum operating temperature for the IVAR W8500020?
The maximum operating temperature is +100 °C. The spacer is not suitable for use at temperatures above this limit.
Can the IVAR W8500020 be used in compressed air systems?
No, the spacer is not suitable for use with compressed air. The technical documentation specifies that it is not appropriate for use with gases or fluids containing oils or hydrocarbons.
Additional parameters
| Category: | BRA.W8.500 - Vibration dampening intermediate piece |
|---|---|
| Warranty: | 2 years |
| Weight: | 1.753 kg |
| Nominal size (DN): | DN 20 |
| Connection type: | flange |
| Material: | steel / cast iron |
| Material: | - flanges |
| Nominal diameter: | DN 20 |
| Nominal pressure: | PN 10 |
| Posledná aktuálizacia ceny: | 13.04.2026 1:08:12 |
Discussion
Be the first who will post an article to this item!