This domestic water pump is commonly integrated into central water supply systems for single-family homes, apartments, and small commercial buildings. Installers typically use such units to ensure consistent water delivery when the mains pressure is insufficient or when boosting pressure is required for upper floors or large layouts. These pumps operate alongside expansion vessels and pressure switches, ensuring stable water pressure and flow. They are often installed in mechanical rooms or dedicated pump houses, where access for maintenance and inspection is available. The compact design allows for easy integration into standard utility spaces.

The IBO JET 100 A is designed for use in closed-loop systems and direct water supply applications. It is particularly suited for systems where the incoming mains cannot provide sufficient pressure for all fixtures. The unit ensures even distribution and avoids fluctuations that could affect the performance of taps, showers, and appliances. When installing, attention must be paid to correct orientation, pipe alignment and electrical connections to prevent vibration and noise issues during operation.

Technical parameters

EAN8585054501083
Length of inlet cable (m)1
Maximum flow rate (l/min)60
Pump voltage (V)230 V
Dimensions H x W x D (cm)82.5x89x50
Pump head (m)50
Weight27.05 kg
CodePR_38702
BrandAQUA OLA
The maximum flow rate of 60 l/min indicates the capacity for delivering water under normal operating conditions, while the total head of 50 m determines the pump’s ability to overcome vertical lift and friction losses in the pipework. These figures are essential for correctly dimensioning the pump to match the building layout and demand. The 230 V supply voltage ensures compatibility with standard single-phase domestic power supplies. The 1 m inlet cable length should be considered when planning the distance between the pump and the electrical source.

Installation and connection

Proper installation involves securing the pump on a solid base, aligning the inlet and outlet ports with the pipework, and ensuring all joints are leak-free. The pump features standard threaded connections, which should be verified against the existing system's specifications. Before energising the unit, the installer must confirm that the electrical supply matches the rated voltage and that the circuit is protected with a suitable fuse or circuit breaker. Common installation errors include incorrect pipe sizing, failure to bleed air from the system, or neglecting to install a non-return valve downstream of the pump to prevent backflow.

Checkpoints after installation include verifying the direction of rotation (if applicable), confirming stable pressure levels, and listening for unusual noises that might indicate misalignment or air in the system. The pump should be tested under load conditions to ensure it maintains the expected flow and pressure over time. The 1 m cable length requires careful routing to avoid strain on the connector and to ensure compliance with local wiring regulations.

Compatibility and accessories

This pump is compatible with standard domestic water supply systems and can be used in conjunction with expansion vessels and pressure switches to automate operation. For optimal performance, it is recommended to install a filter upstream of the pump to reduce the risk of clogging from particulate matter in the water. Additional components such as pressure gauges and isolation valves may also be necessary for monitoring and maintenance purposes. Installers should verify the compatibility of all ancillary equipment with the pump’s operating conditions and flow characteristics.

Technical background for designers

The IBO JET 100 A operates using an electric motor driving an impeller to generate centrifugal force, which increases the kinetic energy of the water and converts it into pressure head. The internal components are typically constructed from durable materials such as stainless steel or corrosion-resistant plastics, ensuring long-term reliability in wet environments. The pump integrates into the system via standard threaded connections and is controlled either manually or via a pressure switch that activates the motor when the system pressure drops below a set threshold.

Designers should consider the hydraulic resistance of the entire system, including pipe lengths, fittings and fixture demands, to ensure the pump is sized correctly. The efficiency of the unit depends on maintaining a steady flow path without unnecessary restrictions or air ingress. Longevity is enhanced by regular inspection of seals and bearings, as well as keeping the motor dry and free from excessive vibration.

Service and operation

Maintenance includes periodic checks of the motor insulation, bearing condition, and overall cleanliness of the pump housing. Any signs of leakage around the seals or abnormal vibrations should be investigated immediately. The pump should be isolated from the system using shut-off valves before carrying out any inspection work. No specific service intervals are provided in the technical data, but regular visual and operational checks are recommended to ensure continued performance and early detection of potential issues.

During routine operation, the pump should maintain a steady pressure level without frequent cycling, which can indicate problems such as low water levels or air pockets in the system. The user should monitor for irregular noise or reduced flow, which may signal the need for cleaning or repair.

Frequently asked questions

Can the IBO JET 100 A be used in a system with an expansion vessel?
Yes, the pump is suitable for use with an expansion vessel to manage pressure fluctuations and reduce wear on the motor.

What type of electrical supply is required for the pump?
The pump operates on a 230 V single-phase supply, which is standard for most domestic and light commercial applications.

Is it possible to install a pressure gauge with this pump?
Yes, a pressure gauge can be added to the system to monitor the operating pressure and detect anomalies in performance.

What precautions should be taken during installation to avoid damage?
Ensure all pipe connections are properly aligned and tightened, avoid bending the 1 m inlet cable, and confirm the electrical circuit is correctly fused before energising the unit.

Additional parameters

Category: Domestic water pressure system
Weight: 51.975 kg
EAN: 8585054501083
Pump application: domestic waterworks
Max. head: 21 – 50 m
Voltage: 230 V
Dimensions H x W x D (cm): 82.5x89x50
Maximum flow rate (l/min): 60
Pump delivery head (m): 50
Pump version - voltage (V): 230 V
Supply cable length (m): 1
EAN: 8585054501083