Product detailed description

Hot water filtration systems in commercial and industrial buildings require reliable mechanical impurity removal to maintain system efficiency and longevity. This 10-inch filter is commonly used in heating and hot water circuits where particulate matter can accumulate and cause blockages or damage to downstream components. Installers working on systems such as central heating, hot water storage, and circulation loops will find this model suitable for integration into existing pipe networks. The filter is designed for installation in systems operating at up to 80°C, making it suitable for applications where hot water temperatures are standard.

Typical installation environments include industrial kitchens, commercial laundries, and large-scale heating systems. The filter is installed in the supply line to intercept and capture suspended particles before they reach sensitive equipment such as heat exchangers, pumps, or valves. The compact design allows for installation in tight spaces, and the modular nature of the filter body enables easy access for maintenance and cartridge replacement.

Technical parameters

MaterialFilter head brass
Operating temperature+80 °C
Nominal pressurePN 8
Mounting keyCode 125.210.50
Code101.142.00
BrandIVAR
The maximum operating temperature of +80 °C and a nominal pressure rating of PN 8 are critical for selecting the correct filter for hot water systems. These parameters ensure compatibility with systems operating under standard hot water conditions. The brass filter head provides resistance to corrosion and thermal expansion, while the TROGAMID filter housing offers durability and chemical resistance. The specified mounting key is essential for secure installation and alignment during assembly.Installation and connection The filter is connected using 6/4 inch F (female) threads, requiring appropriate pipe fittings for secure installation. Installers should ensure that the filter is positioned in the flow direction indicated on the body to prevent improper operation. A mounting key with code 125.210.50 is required for tightening the filter body and securing the cartridge compartment. Common installation errors include incorrect orientation, failure to use the correct mounting key, and neglecting to check for debris in the system before installation. It is recommended to install the filter in a location that allows for easy access to the cartridge compartment for future maintenance.Compatibility and accessories This filter is compatible with various 10-inch filter cartridges, including the GEL 90" model for temperatures above +40 °C. For use with the GEL.DEPURA 3000 OTR model, only 10"/3000 filter cartridges are suitable. The filter head is designed to accommodate different cartridge types, allowing for flexibility in filtration media selection. When ordering, ensure that the appropriate filter cartridge and mounting key are included to complete the installation.Technical background for designers The filter operates by directing water through a replaceable cartridge that captures suspended particles. The brass filter head provides a durable and corrosion-resistant housing, while the TROGAMID filter body offers resistance to thermal and chemical stress. The system integrates into hot water circuits by intercepting particulate matter before it reaches sensitive components. The efficiency of the filter depends on the type of cartridge used and the frequency of maintenance. The maximum operating temperature of +80 °C and the PN 8 pressure rating are essential for ensuring long-term performance in hot water systems.Service and operation Regular inspection and cartridge replacement are necessary to maintain filtration efficiency. The absence of a built-in cartridge means that the filter must be fitted with a suitable replacement before operation. The filter should be checked for signs of wear, blockage, or corrosion during routine maintenance. No specific service intervals are provided in the brief; however, it is recommended to follow the manufacturer's guidelines for cartridge replacement based on system usage and water quality.Frequently asked questions

Can this filter be used with stainless steel filter cartridges?
Yes, stainless steel filter cartridges such as the GEL 90" can be used, especially for systems operating above +40 °C.

Is the filter suitable for installation in a hot water circulation loop?
Yes, the filter is designed for hot water systems and can be installed in circulation loops to prevent particulate matter from entering sensitive components.

What is the maximum operating temperature of the filter?
The filter is rated for a maximum operating temperature of +80 °C, making it suitable for standard hot water applications.

Can the filter be used with the GEL.DEPURA 3000 OTR model?
Yes, but only 10"/3000 filter cartridges are compatible with the GEL.DEPURA 3000 OTR model.

Additional parameters

Category: Filters for drinking water
Weight: 3 kg
Product type: filter / dirt separator
Thread size: 6/4"
Connection type: female thread
Material: brass
Installation wrench: code 125.210.50
Material: filter head brass
Nominal pressure: PN 8
Operating temperature: +80 °C